Upload files to "/"

This commit is contained in:
2026-11-16 17:40:21 +00:00
parent d7ab1b823e
commit 45efc8239d
4 changed files with 1245 additions and 276 deletions
+247 -1
View File
@@ -4,7 +4,253 @@ All notable changes to BD Fresnel are documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
## [Unreleased]
## [3.0] - 2026-11-14
### Added
- **Semi-analytical** algorithm, selectable from a third toggle in the
Operation mode box alongside **Fresnel propagation**:
- Instead of propagating the exit field to the detector by FFT, it
uses closed-form expressions for the power difference and total at
the detector, already integrated over the detector plane. Only an
integral over time at each delay remains.
- The time window runs +/- 5T about each delay, where T = tau_p/tau_e.
- Transmission is the energy total normalised to its value before the
pump arrives: the first delay point when fitting, and
min(-3 rho, -3) tau_e when simulating, so a thin sample with
rho -> 0 still normalises away from the peak.
- `X_num` and `X_max` are disabled in this mode: the expressions are
already integrated over space, so there is no spatial grid.
- Applies to both measurement modes. In pump probe the probe is
centred, x_0 = 0, so the deflection term vanishes identically and
the transmission alone is calculated.
- Both algorithms are kept so results can be compared. Switching
discards the current result, which belongs to the other method.
- The algorithm is saved with the other settings and recorded in the
parameter log.
- The absorptive term in the deflection expression carries a
PROVISIONAL coefficient, `SA_ABSORPTIVE_FACTOR`. As derived, that
term matched neither the sign nor the magnitude of the Fresnel
result: a purely absorptive mechanism disagreed by a factor of
about -69, with correlation exactly -1. Dividing by
D = d / (pi w_0_p^2 / lambda_p) = d / z_0_p accounts for the distance and
wavelength dependence exactly, and is independent of sample
thickness at constant alpha_2_exp*l; the remaining -1/(1 + 2W^2) was
measured against the Fresnel path rather than derived. With it the
two methods agree to 0.5% for mechanisms with a refractive part and
4.5% for purely absorptive ones. It is isolated in one function
pending a corrected derivation.
- The parameter log's `Calculated Parameters (pump)` section reports
`sigma_e`, the normalised pump linear absorption `alpha_e * L / 2`.
It sits next to `T_lin`, which restates it: with no pump two-photon
absorption `T_lin = (1 - R_p) exp(-2 sigma_e)`. Read from the
parameters rather than the result, so it is reported for either
algorithm.
- The `Other` panel and the parameter log's `Other` section both report
`eta (peak)` and `Gamma (peak)`, the largest nonlinear phase and
absorption exponent anywhere on the grid, from whichever algorithm
produced the result. These are the only readouts in those panels that
come from the result rather than from the parameters, since they are
peaks over the whole (T, T_d) grid and cannot be had without running
the calculation. They therefore show `--` until a Fit or Simulate
completes, and return to `--` whenever that result is discarded, so a
stale phase is never displayed beside freshly edited parameters.
`eta (peak)` is the yardstick for the semi-analytical algorithm's
validity: its `dP` is first order in the response while Fresnel
propagation keeps every order, so the two agree only while the phase
is small. On the 4-layer mechanisms the peak of `DeltaEoE` sits at
the same delay to within 0.0003 tau_e at `eta (peak)` = 0.14, but
0.0035 at 1.41, 0.077 at 5.6 and 0.36 at 14.1. Holding `eta (peak)`
fixed, the agreement is unaffected by sample thickness (0.05 to
2 mm), by walk-off (`rho` 0.04 to 1.7) and by pump absorption
(`sigma_e` 0 to 10), so this one number sets the regime. Both
algorithms report it to within 2e-5 of each other.
### Changed
- **Both beams are now explicitly subscripted: the pump carries `_e`
(excitation) and the probe carries `_p`.** This restores the
convention the original MATLAB used, which the Python port had
partly inverted (`_p` for the pump) and partly dropped (no suffix
for the probe). No beam quantity is unsubscripted any more; the only
unsuffixed parameters left are the ones belonging to neither beam --
the sampling grid, the sample geometry (`l`, `d`, `shift`), the
relative offset `x_0`, and the walk-off `rho`.
| pump: was | now | | probe: was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_FWHM` | `tau_p_FWHM` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `w_0` | `w_0_p` |
| `w_0p` | `w_0_e` | | `lambda_` | `lambda_p` |
| `lambda_p` | `lambda_e` | | `R` | `R_p` |
| `R_p` | `R_e` | | `alpha` | `alpha_p` |
| `alpha_p` | `alpha_e` | | `n` | `n_p` |
| `n_p` | `n_e` | | `dndl` | `dndl_p` |
| `dndl_p` | `dndl_e` | | `tau` | `tau_p` |
| `alpha_2d` | `alpha_2d_e` | | `ng` | `ng_p` |
| `tau_p` | `tau_e` | | `z_0` | `z_0_p` |
| `sigma_p` | `sigma_e` | | `Tlin` | `Tlin_p` |
| `I_0_p` | `I_0_e` | | | |
| `ng_p` | `ng_e` | | | |
| `z_0_p` | `z_0_e` | | | |
| `Tlin_p` | `Tlin_e` | | | |
| `sigma_p2` / `sigma_p20` | `sigma_e2` / `sigma_e20` | | | |
| `a_p_0`, `W_0_p`, `I_p_pulse` | `a_e_0`, `W_0_e`, `I_e_pulse` | | | |
Note that six probe names -- `tau_p_FWHM`, `lambda_p`, `R_p`,
`alpha_p`, `n_p`, `dndl_p` -- are spelled exactly like what were
**pump** names before this release. Reading an old log or settings
file alongside a new one needs care; see the settings note below for
how the program itself is protected.
The pump pass renamed 389 identifier occurrences textually; the
probe pass was done by rewriting 116 exact AST node positions
instead, because `n`, `R`, `alpha` and `tau` are overloaded in this
codebase (lambda parameters, the author's initials in the copyright
line, the semi-analytical formula's geometric `R`, a diagnostics
dict key) and no text pattern distinguishes them.
| was | now | | was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_p` | `tau_e` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `sigma_p` | `sigma_e` |
| `w_0p` | `w_0_e` | | `I_0_p` | `I_0_e` |
| `lambda_p` | `lambda_e` | | `ng_p` | `ng_e` |
| `R_p` | `R_e` | | `z_0_p` | `z_0_e` |
| `alpha_p` | `alpha_e` | | `Tlin_p` | `Tlin_e` |
| `n_p` | `n_e` | | `sigma_p2` | `sigma_e2` |
| `dndl_p` | `dndl_e` | | `sigma_p20` | `sigma_e20` |
| `alpha_2d` | `alpha_2d_e` | | `a_p_0` | `a_e_0` |
`w_0p` gains the separating underscore it was missing, so the field
name finally matches the variable that held it (`w_0_p`) and its
siblings `z_0_e` and `I_0_e`. `alpha_2d_e` keeps the `d` for
degenerate.
- **The Electronic mechanism's parameters are renamed `alpha_2e` ->
`alpha_2el` and `n_2e` -> `n_2el`**, since their `e` meant
*electronic* and would otherwise collide with `_e` for excitation --
the pump's degenerate two-photon coefficient would have wanted the
name `alpha_2e`, which was taken. `_e` now means excitation and
nothing else.
- `BD_3_level_triplet`, `I_e_func` and `excite_prop` needed no
renaming at all: transliterated from the MATLAB, they already used
`_e` for the pump and `_p` for the probe, so `n_g_p`, `v_p` and
`I_p` inside them were correct all along. With both beams now
subscribed to that convention, the whole file reads against the
MATLAB without translation.
- **`last_settings.json` written by an earlier version is now refused
rather than misread.** Saved settings carry a `settings_schema`
stamp, and a file without the current one is rejected with a message
explaining why. This is not housekeeping: because six probe field
names are spelled exactly like former pump keys, loading an old file
by name alone would have installed the pump's wavelength, index,
reflectivity, absorption and dispersion as the *probe's* -- every
number plausible, every result wrong. Re-enter the parameters once
and they save in the new layout. Any other unrecognised key is still
dropped with a note on stderr.
- Log and panel labels follow their fields on both sides: `n_g_e`,
`sigma_e`, `T_lin_e`, `z_0_e`, `I_0_e` for the pump and `n_g_p`,
`T_lin_p`, `z_0_p` for the probe, with the beam parameters and
material blocks likewise. The GUI's pump calculated-parameters panel
also gains a `sigma_e` readout, which it had not displayed before.
- `T_lin_p` and `T_lin_e` are labelled `T_lin_p (transmission)` and
`T_lin_e (transmission)` in both the panel and the log, so the
quantity is named and not just abbreviated. The log's value column
moved from 25 to 29 to fit them, and the panel's label column from 20
to 23 characters -- which also squares up `z_0_p (Rayleigh range)`,
`z_0_e (Rayleigh range)` and `I_0_e (peak irradiance)`, all of which
had been overrunning the old 20 and pushing their own values out of
line.
- The rename is numerically inert: across 8 mechanism types x 2
algorithms x 3 pump-absorption configurations (49 cases, 3275
values), `DeltaEoE`, `T`, `Delta_n`, `eta_peak` and `Gamma_peak` are
bit-identical to the pre-rename code, and `pyflakes` reports zero
warnings before and after.
- Transmission y-axis tick labels are limited to three significant
digits, so "99.75" reads "99.8". The count is a floor rather than a
cap: a shallow scan spanning a few hundredths of a percent would
round every tick to "100", so digits are added only where that would
happen. The deflection axis is unaffected.
- The reference list in the README and the parameter log follows Optica
style: every author listed, initials first, abbreviated journal,
volume, full page range, year. Author lists and page ranges were
checked against the published papers.
- The duplicate supplementary-material citation is dropped, leaving two
references.
- The parameter log is written as UTF-8. The citations use typographic
quotes and an en dash, which the locale's encoding cannot always
represent.
### Fixed
- The instantaneous (Electronic) response for a sample with both
walk-off and pump absorption is evaluated through the scaled
complementary error function `erfcx` instead of the form in
`BD_Fresnel_func_ni.m`. That form multiplied `exp(sigma_e^2/rho^2 +
2 sigma_e u/rho)` by a difference of error functions falling to zero,
so the product was lost to cancellation well before it overflowed:
at `rho = 0.4336` (l = 0.5 mm) it was already wrong over 8.6% of the
delay axis at `sigma_e = 2.5` (alpha_e = 100 cm^-1), **returning
exactly 0.0 with no NaN to signal it**, and returned NaN above
`sigma_e = 3`. The usable ceiling on `alpha_e` for an Electronic
mechanism at that thickness was therefore about 60 cm^-1, not the
~120 where NaN first appeared. The rearrangement is algebraic, with
every surviving exponent non-positive; it reproduces the original
evaluated at 600 decimal digits to 1e-16..3e-13 relative over
`sigma_e` = 0.25 to 10 and `u` = -3 to 18, both where the original
works and where it does not.
- Pump absorption is applied to non-instantaneous mechanisms when the
walk-off is exactly zero. Substituting `T1 = (T+T_d) - rho +
rho*zeta` shows the `rho != 0` branch to be a depth average over
`atten_fac`, whose `rho -> 0` limit is the response at one instant
times the *mean* of `atten_fac`; the original used the bare response.
The dropped factor is `(1 - exp(-2 sigma_e))/(2 sigma_e)` for linear
pump absorption, so the response was previously **independent of
`alpha_e` altogether** in this case -- identical at `alpha_e` = 0 and
200 cm^-1. It was 1.27x too large at `alpha_e` = 10 cm^-1 and
l = 0.5 mm, and 10x at 200 cm^-1. The two branches now agree to nine
digits across `rho = 0`. This affects only samples with `ng_p` exactly
equal to `ng_e` (for example no dispersion entered at either
wavelength) *and* non-zero pump absorption; with `alpha_e = alpha_2d_e
= 0` the mean is exactly 1 and results are bit-identical to before.
- Pump absorption through the sample depth, `atten_fac`, is computed
from the closed-form solution of
`dI_e/dz = -alpha_e I_e - alpha_2d_e I_e^2` rather than the two-branch
expression carried over from `BD_Fresnel_func_ni.m`. That expression's
pump two-photon branch, `sqrt((B1 B2)/sigma_e)`, failed three ways: it
did not reduce to its own `sigma_e2 == 0` branch as `alpha_2d_e -> 0`
(it decayed at half the correct rate), it divided by zero whenever
`alpha_e` was zero, and it took the square root of a negative number
whenever `sigma_e20 > sigma_e`. The net effect was that **every run
combining a non-zero `alpha_2d_e` with a non-instantaneous mechanism
returned NaN at every delay** -- pump two-photon absorption worked
only for the Electronic mechanism, which does not use `atten_fac`.
Dropping the stray square root recovers that expression as the
linearisation of the exact one in `sigma_e20`, which is how the
intent was identified. Results for `alpha_2d_e = 0` are bit-identical
to before; the new form agrees with numerical integration of the
pump propagation equation to 2e-12 relative over `sigma_e` and
`sigma_e20` from 0 to 20, including both limits.
- A negative `alpha_2d_e` large enough to make the pump diverge inside
the sample (two-photon gain, no finite depth average) is now refused
with a message naming the largest `|alpha_2d_e|` that works for the
current thickness and pump irradiance, rather than silently returning
a meaningless attenuation of order 1e12.
- `mpmath` is imported only where it is used, in the pump two-photon
absorption term. Importing it at module level made an optional
dependency fatal at startup, so the program would not run at all
without it. If that term is ever reached without mpmath installed,
the error now says which package is missing and why.
## [2.6] - 2026-09-30