From 49bc1dc6447920a349a74b333827d15ac7bfc024 Mon Sep 17 00:00:00 2001 From: manuel Date: Tue, 17 Nov 2026 00:13:07 +0000 Subject: [PATCH] Update README.md --- README.md | 24 ++++++++++++------------ 1 file changed, 12 insertions(+), 12 deletions(-) diff --git a/README.md b/README.md index 448ad5c..bdf8c7e 100644 --- a/README.md +++ b/README.md @@ -4,11 +4,11 @@ Beam-deflection pump–probe simulator and fitting tool. A Python port of the MATLAB `BD_Fresnel_GUI` suite. The program models a weak probe beam crossing a sample that has been excited by -a strong pump, propagates the perturbed probe field to a detector by Fresnel -diffraction, and computes the transmission `T` and normalised beam deflection -`ΔE/E` as a function of pump–probe delay. Measured scans can be imported and -compared against the simulation, and the result exported as data, a log, and -publication-sized figures. +a strong pump, propagates the perturbed probe field to the detector and computes +the transmission `T` and normalised beam deflection `ΔE/E` as a function of +pump–probe delay. Measured scans can be imported and compared against the +simulation, and the result exported as data, a log, and publication-sized +figures. Two measurement modes are supported. **Beam deflection** fits both signals. **Pump probe** is for measurements with the probe centred on the pump, where @@ -159,8 +159,8 @@ the detector plane, then integrates each over time at every delay to get the energy difference `dE` and total `E`. The deflection is `dE/E` and the transmission is `E` normalised. With no spatial grid to size, `X_num` and `X_max` are greyed out; every other parameter, `Delta_n` included, is -unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about -**32x faster**. +unaffected. On the four-layer graphene example it runs in 0.11 s against 3.65 s, +about **32x faster**. The trade-off is that `dP` is **first order in the nonlinear response**, where the Fresnel path keeps every order. The two therefore agree only while the @@ -173,11 +173,11 @@ phase is small, which the `eta (peak)` line of the parameter log reports: | 5.64 rad | 0.077 tau_e | | 14.1 rad | 0.36 tau_e | -Below roughly 1 rad the two are interchangeable, and the four-layer example sits -at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a -few rad the semi-analytical curve shifts noticeably and is no longer a -substitute. Sample thickness, walk-off and pump absorption do not themselves -affect the agreement once `eta (peak)` is held fixed. +Below roughly 1 rad the two are interchangeable, and the four-layer graphene +example sits at 0.049 rad with a correlation of 1.000000 and amplitudes within +0.5%. Above a few rad the semi-analytical curve shifts noticeably and is no +longer a substitute. Sample thickness, walk-off and pump absorption do not +themselves affect the agreement once `eta (peak)` is held fixed. The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`