@@ -38,6 +38,10 @@ entered by hand, and only the calculated curves are plotted and exported.
offers only the mechanisms that can change the transmission.
- Fitting and simulation run modes. Simulation computes the signal with no
data imported, over a delay range entered in the panel.
- Two interchangeable algorithms. Fresnel propagation carries the exit field to
the detector by FFT; the semi-analytical method uses closed-form detector
power expressions instead, needing no spatial grid and running about 32x
faster, at the cost of holding only to first order in the nonlinear response.
- Optional diagnostic figures showing each mechanism's response function before
and after convolution, plus the ESA populations and beam transmissions.
- Export of the data/fit comparison, a full parameter log, and figures at
@@ -71,8 +75,9 @@ right: **Fitting**, **Diagnostics**, and **Parameter log**.
Fitting a measured scan:
1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**, and
leave the second toggle on **Fitting**.
1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**,
leave the second toggle on **Fitting**, and pick an algorithm on the third:
**Fresnel propagation** or the faster **Semi-analytical**.
2. Set the **Data columns** to match your file, and the delimiter.
3. Press **Import…** and choose a scan. The plots show the measured data.
4. Fill in the beam, material and geometry parameters, and configure one or
@@ -83,7 +88,8 @@ Fitting a measured scan:
Simulating without a measurement:
1. Under **Operation mode**, choose **Simulation**. **Import…** and the data
column fields are disabled, and **Fit** becomes **Simulate**.
column fields are disabled, and **Fit** becomes **Simulate**. The algorithm
toggle works the same way as in Fitting mode.
2. Set `T_d_min` and `T_d_max` in **Simulation parameters** to the delay range
to compute over. In Fitting mode these come from the imported file, so they
are editable only here.
@@ -108,11 +114,11 @@ deflection needs three columns and pump probe two; which ones is set in the
**Data columns** box, so extra columns can be present and ignored. Each
quantity must come from a different column.
| Quantity | Units | Default column | Needed in |
| --- | --- | --- | --- |
| `τ_d` | fs | 1 | both modes |
| `ΔE/E` | fractional | 2 | Beam deflection only |
| `T` | fractional (1.0 = no change) | 3 | both modes |
| Quantity | Units | Default column | Needed in |
|----------|------------------------------|----------------|----------------------|
| `τ_d` | fs | 1 | both modes |
| `ΔE/E` | fractional | 2 | Beam deflection only |
| `T` | fractional (1.0 = no change) | 3 | both modes |
The delimiter field takes a single character, `\t` for a tab, or is left blank
to split on any run of whitespace.
@@ -121,92 +127,147 @@ to split on any run of whitespace.
### Data columns (1-indexed)
| Variable | Default | Column contents |
|-------------------|---------|---------------------------------------|
| `tau_d column` | `1` | Delay column (fs) |
| `T column` | `3` | Transmission data column |
| `DeltaEoE column` | `2` | Deflection data column |
| `Delimiter` | `,` | Data column delimiter character |
| Variable | Default | Column contents |
|-------------------|---------|---------------------------------|
| `tau_d column` | `1` | Delay column (fs) |
| `T column` | `3` | Transmission data column |
| `DeltaEoE column` | `2` | Deflection data column |
| `Delimiter` | `,` | Data column delimiter character |
### Operation mode
| Option | Effect |
|-------------------|-------------------------------------------------|
| `Beam deflection` | Transmission and deflection, offset probe |
| `Pump probe` | Transmission only, centered probe |
| `Fitting` | Compare the calculation against an imported scan |
| `Simulation` | Calculate without a scan, over an entered range |
Three independent toggles. Any combination is valid.
| Toggle | Option | Effect |
|-------------|-----------------------|--------------------------------------------------|
| Measurement | `Beam deflection` | Transmission and deflection, offset probe |
| | `Pump probe` | Transmission only, centered probe |
| Run | `Fitting` | Compare the calculation against an imported scan |
| | `Simulation` | Calculate without a scan, over an entered range |
| Algorithm | `Fresnel propagation` | Propagate the exit field to the detector by FFT |
| | `Semi-analytical` | Closed-form detector power, no spatial grid |
#### Algorithm
**Fresnel propagation** is the original method. The field at the exit face is
built on an (x, y) grid, propagated to the detector by FFT, and integrated over
the detector halves to get the power difference and total at each instant.
**Semi-analytical** skips the propagation. It evaluates closed-form expressions
for the detector power difference `dP` and total `P`, already integrated over
the detector plane, then integrates each over time at every delay to get the
energy difference `dE` and total `E`. The deflection is `dE/E` and the
transmission is `E` normalised. With no spatial grid to size, `X_num` and
`X_max` are greyed out; every other parameter, `Delta_n` included, is
unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about
**32x faster**.
The trade-off is that `dP` is **first order in the nonlinear response**, where
the Fresnel path keeps every order. The two therefore agree only while the
phase is small, which the `eta (peak)` line of the parameter log reports:
| `eta (peak)` | Peak of `DeltaEoE` displaced by |
|--------------|---------------------------------|
| 0.14 rad | 0.0003 tau_e |
| 1.41 rad | 0.0035 tau_e |
| 5.64 rad | 0.077 tau_e |
| 14.1 rad | 0.36 tau_e |
Below roughly 1 rad the two are interchangeable, and the four-layer example sits
at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a
few rad the semi-analytical curve shifts noticeably and is no longer a
substitute. Sample thickness, walk-off and pump absorption do not themselves
affect the agreement once `eta (peak)` is held fixed.
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`
is the pump amplitude profile, while the semi-analytical form uses the on-axis
`exp(-2 x_0^2)`.
One coefficient in `dP`'s absorptive term, `SA_ABSORPTIVE_FACTOR`, is at present
fitted against the Fresnel path rather than derived. It is isolated in a single
function in `bd_fresnel_core.py`, with the measurements behind it recorded
there.
The transmission needs a reference delay, taken from before the pump arrives.
In **Fitting** mode it is the first delay point of the imported scan; in
**Simulation** mode it is `min(-3 rho, -3)` tau_e, which follows the walk-off
when that is the larger scale and is three pulse widths otherwise, so a thin
sample still normalises away from the peak.
### Simulation parameters
| Variable | Default | Column contents |
|----------------|---------|---------------------------------------|
| `X_num` | `50` | Number of spatial points |
| `X_max` | `5.0` | Range of spatial sampling (w_0) |
| `T_num` | `100` | Number of temporal points |
| `T_max` | `5.0` | Range of temporal sampling (tau_p) |
| `T_d_num` | `150` | Number of delay points over range |
| `T_d_min` | `-5.0` | Delay range start (tau_p), Simulation only |
| `T_d_max` | `5.0` | Delay range end (tau_p), Simulation only |
| Variable | Default | Column contents |
|-----------|---------|-------------------------------------------------|
| `X_num` | `50` | Number of spatial points, Fresnel only |
| `X_max` | `5.0` | Range of spatial sampling (w_0_p), Fresnel only |
| `T_num` | `100` | Number of temporal points |
| `T_max` | `5.0` | Range of temporal sampling (tau_e) |
| `T_d_num` | `150` | Number of delay points over range |
| `T_d_min` | `-5.0` | Delay range start (tau_e), Simulation only |
| `T_d_max` | `5.0` | Delay range end (tau_e), Simulation only |
`X_num` and `X_max` size the spatial grid the Fresnel method propagates, so the
semi-analytical method greys them out.
### Excitation beam parameters
| Variable | Default | Column contents |
|----------------|---------|---------------------------------------|
| `E_p` | `1.36` | Excitation pulse energy (uJ) |
| `tau_p_FWHM` | `55.0` | Excitation pulse duration (fs) |
| `w_0p` | `246.0` | Excitation beam waist (um) |
| `lambda_p` | `800.0` | Excitation pulse wavelength (nm) |
| Variable | Default | Column contents |
|--------------|---------|----------------------------------|
| `E_e` | `1.36` | Excitation pulse energy (uJ) |
| `tau_e_FWHM` | `55.0` | Excitation pulse duration (fs) |
| `w_0_e` | `246.0` | Excitation beam waist (um) |
| `lambda_e` | `800.0` | Excitation pulse wavelength (nm) |
### Probe beam parameters
| Variable | Default | Column contents |
|----------------|---------|---------------------------------------|
| `tau_FWHM` | `60.0` | Probe pulse duration (fs) |
| `w_0` | `43.0` | Probe beam waist (um) |
| `lambda` | `650.0` | Probe pulse wavelength (nm) |
| Variable | Default | Column contents |
|--------------|---------|-----------------------------|
| `tau_p_FWHM` | `60.0` | Probe pulse duration (fs) |
| `w_0_p` | `43.0` | Probe beam waist (um) |
| `lambda_p` | `650.0` | Probe pulse wavelength (nm) |
### Material parameters at excitation wavelength
| Variable | Default | Column contents |
|----------------|-------------|-----------------------------------|
| `R_p` | `0.0` | Reflectivity |
| `alpha_p` | `0.0` | Linear absorption (cm^-1) |
| `n_p` | `1.4533` | Linear index |
| `dndl_p` | `-0.017284` | First order dispersion (um^-1) |
| `alpha_2d` | `0.0` | 2 photon absorption (e-11 m/W) |
| Variable | Default | Column contents |
|--------------|-------------|--------------------------------|
| `R_e` | `0.0` | Reflectivity |
| `alpha_e` | `0.0` | Linear absorption (cm^-1) |
| `n_e` | `1.4533` | Linear index |
| `dndl_e` | `-0.017284` | First order dispersion (um^-1) |
| `alpha_2d_e` | `0.0` | 2 photon absorption (e-11 m/W) |
### Material parameters at probe wavelength
| Variable | Default | Column contents |
|----------------|-------------|-----------------------------------|
| `R` | `0.0` | Reflectivity |
| `alpha` | `0.0` | Linear absorption (cm^-1) |
| `n` | `1.4565` | Linear index |
| `dndl` | `-0.027158` | First order dispersion (um^-1) |
| Variable | Default | Column contents |
|-----------|-------------|--------------------------------|
| `R_p` | `0.0` | Reflectivity |
| `alpha_p` | `0.0` | Linear absorption (cm^-1) |
| `n_p` | `1.4565` | Linear index |
| `dndl_p` | `-0.027158` | First order dispersion (um^-1) |
### Measurement parameters
| Variable | Default | Column contents |
|----------------|-------------|-----------------------------------|
| `l` | `1.0` | Sample thickness (mm) |
| `d` | `15.0` | Distance to detector (cm) |
| `shift` | `0.0` | Temporal shift (fs) |
| `x_0` | `0.5` | Displacement of probe (w_0p) |
| Variable | Default | Column contents |
|----------|---------|-------------------------------|
| `l` | `1.0` | Sample thickness (mm) |
| `d` | `15.0` | Distance to detector (cm) |
| `shift` | `0.0` | Temporal shift (fs) |
| `x_0` | `0.5` | Displacement of probe (w_0_e) |
## Mechanisms
| Mechanism | Parameters |
| --- | --- |
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
| Mechanism | Parameters |
|--------------------------------|------------|
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
`NLR` denotes a purely refractive response, `NLA` a purely absorptive one, and
`both` a mechanism carrying each.
@@ -221,14 +282,14 @@ is still empty.
Exporting to `<name>_fit.txt` also writes, in the same directory:
| File | Contents |
| --- | --- |
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
| File | Contents |
|----------------------------------------|------------------------------------------------------------------------------------------------------------------------------|
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
The last two appear only when *Show diagnostic plots during Fit* is ticked.
@@ -244,25 +305,23 @@ path and data column sections are omitted, having nothing to describe.
## Files
| File | Role |
| --- | --- |
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
| File | Role |
|------------------------|--------------------------------------------------------------------------------------------------------------------------|
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
## References
Please cite the following when using results from this program.
1. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
dependence of the nonlinear optical response of carbon disulfide."
*Optica* **1**(6): 436.
2. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
dependence of the nonlinear optical response of carbon disulfide:
supplementary material." *Optica* **1**(6): 436.
3. Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and
polarization resolved ultrafast nonlinear refraction." *Opt. Lett.*
**38**(18): 3518–3521.
1. M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, T. R. Ensley,
D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and
E. W. Van Stryland, “Temporal, spectral, and polarization dependence of the
nonlinear optical response of carbon disulfide,” Optica **1**, 436–445 (2014).
2. M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and E. W. Van Stryland,
“Beam deflection measurement of time and polarization resolved ultrafast
nonlinear refraction,” Opt. Lett. **38**, 3518–3521 (2013).
## License