# Z-Scan Beam Simulation [![License: GPLv3](docs/license-gplv3.svg)](LICENSE) A desktop application for fitting **Z-scan** measurements of nonlinear optical materials. It loads raw open-aperture (OA) and closed-aperture (CA) scan data, applies reference-channel correction and baseline normalization, simulates the expected transmittance from a set of nonlinear coefficients, and fits those coefficients to the measurement. The Z-scan technique measures nonlinear refraction and absorption by translating a thin sample through the focus of a pulsed laser beam and recording transmitted energy as a function of position. This program models the beam propagating through the sample and on to a far-field aperture, and refines the nonlinear coefficients until the simulated curves match the measured ones. The method follows Ferdinandus *et al.*, *Measuring small solute nonlinearities in solution by dual-arm Z-Scan technique* ([FiO 2012, paper FM4I.6](https://doi.org/10.1364/FIO.2012.FM4I.6)) — see [Citing this work](#citing-this-work). ![Fit results with measured data](docs/fit_results.png) ## Features - **Load raw scan files** with configurable 1-indexed column mapping, so data from different acquisition setups can be read without editing the file. A header row is skipped. Leaving the delimiter blank splits on whitespace, which covers tab- and space-separated exports; set it explicitly (`,`) for CSV. - **Reference-channel correction** to divide out shot-to-shot laser fluctuation, plus an optional frequency channel. - **Baseline normalization** by a linear fit through the wings of the scan, where the sample is far from focus and the response should be flat. The fraction of points taken from each end is adjustable. - **Nonlinear refraction and absorption to third order**: n₂, n₃, n₄ and α₂, α₃, α₄. - **Full beam simulation**: Gaussian beam with M² correction, temporal pulse integration, radial propagation to the aperture, and both open- and closed-aperture transmittance. - **Automatic fitting** — tick any subset of the six nonlinear coefficients and refine them by Nelder-Mead simplex against the measured curves. - **Fit quality reporting**: chi-square per curve, peak-to-valley comparisons between data and fit, and a propagated uncertainty estimate from the energy, spot-size and pulse-width errors. - **Export** the fit, a full parameter log, and publication-ready plots. - **Settings persistence** — every field is saved on exit and restored on the next launch. ## Screenshots The left panel holds every processing and physical parameter; results appear in three tabs — the referenced/normalized input data, the fit, and a log of all parameters and fit-quality numbers. **Referenced / normalized data.** Raw and reference-corrected traces with the baseline fit drawn over them. The correction visibly removes laser fluctuation from both channels. ![Reference plot](docs/reference.png) **Log.** Every parameter that produced the fit, plus the fit-quality numbers. ![Log tab](docs/log.png) ## Installation Requires Python 3.8+ and: ``` numpy scipy matplotlib ``` Tkinter ships with most Python installs. On some Linux distributions it is a separate package: ```bash sudo apt install python3-tk # Debian / Ubuntu sudo dnf install python3-tkinter # Fedora ``` Then: ```bash pip install numpy scipy matplotlib python zscan_gui.py ``` ## Usage 1. **Browse** to a scan file and set the column numbers for position, CA, OA and the reference channel. Columns are 1-indexed, matching how they are usually numbered in acquisition software. 2. **Import.** The Referenced / Normalized tab shows the raw and corrected traces with the baseline fit drawn over them, so you can confirm the columns and flags are right before simulating. Changing a column or a processing flag re-reads the file and redraws immediately. 3. **Enter the measurement parameters** — pulse energy, wavelength, beam waist, pulse width, sample thickness and refractive index, aperture transmittance. 4. **Run Simulation** to overlay the simulated curves on the data. 5. **Refine Fit** — tick the coefficients to vary and let the optimizer adjust them. It runs in the background with a live iteration count. 6. **Export** to write the fit data, log and images next to the input file. ### Exported files Written alongside the input file, with an optional extra label in the name: | File | Contents | |---|---| | `_fit.` | CSV of position, data and fit for the OA, CA and CA/OA curves | | `_fit_log.txt` | Every parameter, fit-quality metric and output path | | `_fit.jpg` / `.svg` | Fit figure, raster and vector | | `_fit_ref.jpg` / `.svg` | Referenced/normalized figure | ## Project structure The program is split so the physics can be used without the interface: - **`zscan_core.py`** — the simulation engine. No GUI or pyplot state; figures are built as `matplotlib.figure.Figure` objects so any front end can embed them. Import it directly to drive the simulation from a script or notebook: ```python from dataclasses import replace from zscan_core import load_settings, load_and_normalize_data, run_simulation cfg = replace(load_settings("last_settings.json"), import_filepath="scan.txt") DATA, norm_OA, norm_CA = load_and_normalize_data(cfg) results = run_simulation(cfg, DATA) print(results["OA_chi_square"], results["deltaOAcomp"]) ``` Every parameter lives in a single `ZScanConfig` dataclass, which serializes to and from JSON, so a fit is fully reproducible from its settings file. - **`zscan_gui.py`** — the Tkinter interface. Simulation and fitting run on background threads so the window stays responsive, and plots rescale with it. ## Parameters ## Data columns (1-indexed) | Variable | Default | Column contents | |------------|---------|---------------------------------------| | `z_col` | `0` | Sample position *z* (mm) | | `CA_col` | `1` | Closed-aperture detector signal (V) | | `FREQ_col` | `3` | Frequency / shot-index channel | | `OA_col` | `4` | Open-aperture detector signal (V) | | `REF_col` | `7` | Reference detector signal (V) | | `FREQ_col` | `9` | Lock-in frequency column (V) | ## Processing flags | Parameter | Meaning | |--------------------------------------|-------------------------------------------------------------| | `use_ref` | Apply the reference-channel correction | | `use_freq` | Appliy the frequency-channel correction | | `flip_z` | `1` reverses the sign of the z axis | | `do_norm_OA`, `do_norm_CA` | Fit and divide out the linear wing baseline | | `flip_OA`, `flip_CA`, `flip_REF` | Invert a raw channel about its median (`0` or `1`) | | `flip_OA_disp`, `flip_CA_disp` | Invert the normalized traces about 1 for display/fitting | | `show_CA` | Plot CA in the right panel; if `False`, plot CA/OA instead | ## Nonlinear coefficients | Parameter | Meaning | Units | Log units | |-----------|----------------------------------------|----------|------------| | `n_2` | 3rd-order nonlinear refractive index | m²/W | cm²/GW | | `n_3` | 5th-order nonlinear refractive index | m⁴/W² | cm⁴/GW² | | `n_4` | 7th-order nonlinear refractive index | m⁶/W³ | cm⁶/GW³ | | `alpha_2` | Two-photon absorption coefficient | m/W | cm/GW | | `alpha_3` | Three-photon absorption coefficient | m³/W² | cm³/GW² | | `alpha_4` | Four-photon absorption coefficient | m⁵/W³ | cm⁵/GW³ | ## z-position offsets `Delta_z_OA`, `Delta_z_CA`, `Delta_z_OACA` (mm) shift the OA, CA, and CA/OA z-axes independently so that measured and simulated curves line up when the two detector arms are not perfectly co-registered. ## Sample parameters | Parameter | Meaning | Units | |-------------|---------------------------------------------|-------| | `n` | Linear refractive index | — | | `L` | Sample thickness | m | | `T_lin` | Linear transmittance | — | ## Laser parameters | Parameter | Meaning | Units | |-------------|---------------------------------------------|-------| | `E` | Pulse energy | J | | `lambda` | Wavelength | m | | `w_0` | Beam waist, HW1/e² of irradiance | m | | `tau_FWHM` | Pulse duration, FWHM of irradiance | s | | `M2` | Beam quality parameter M² | — | ## Measurement parameters | Parameter | Meaning | Units | |-------------|---------------------------------------------|-------| | `S` | Linear transmission of the aperture | — | | `d` | Distance from focus to aperture | m | ## Error estimates `E_err`, `w_err`, and `tau_err` are fractional uncertainties on the energy, waist, and pulse duration; they are combined in quadrature into `Tot_err` and written to the log as the systematic uncertainty on the extracted coefficients. — `E_err`, `w_err`, `tau_err`, as fractions, propagated into the reported uncertainty ## Simulation parameters | Parameter | Default | Meaning | |-------------|---------|-----------------------------------------------------| | `z_points` | `75` | Number of z-scan points (must be even) | | `r_points` | `500` | Radial points at the sample | | `r_max` | `3` | Radial integration limit, in beam radii *w* | | `t_points` | `50` | Temporal points | | `t_max` | `3` | Temporal integration limit, in pulse widths *τ* | | `ra_points` | `50` | Radial points at the closed aperture | | `endpts_%` | `10` | Percentage of edge points to use for normalization | | `max_iter` | `100` | Maximum iterations for the parameter refinement | Memory use scales as `r_points x ra_points x t_points x z_points`, so raising the grid resolution raises RAM sharply; the interface shows the estimate as you edit those fields. ## Citing this work If this program contributes to work you publish, please cite the paper the method comes from: > M. R. Ferdinandus, M. Reichert, T. R. Ensley, D. A. Fishman, S. Webster, > D. J. Hagan, and E. W. Van Stryland, "Measuring small solute nonlinearities in > solution by dual-arm Z-Scan technique," in *Frontiers in Optics 2012/Laser > Science XXVIII*, OSA Technical Digest (online) (Optica Publishing Group, > 2012), paper FM4I.6. ```bibtex @inproceedings{Ferdinandus2012DualArmZScan, author = {Ferdinandus, Manuel R. and Reichert, Matthew and Ensley, Trenton R. and Fishman, Dmitry A. and Webster, Scott and Hagan, David J. and Van Stryland, Eric W.}, title = {Measuring small solute nonlinearities in solution by dual-arm {Z}-Scan technique}, booktitle = {Frontiers in Optics 2012/Laser Science XXVIII}, series = {OSA Technical Digest (online)}, publisher = {Optica Publishing Group}, year = {2012}, pages = {FM4I.6}, doi = {10.1364/FIO.2012.FM4I.6}, } ``` The code was written by the paper's first author. It was ported from a MATLAB implementation of this method, then restructured into a separate simulation engine and interface; the physics and array shapes follow the original derivation. ## License Copyright (C) 2019-2026 Manuel R. Ferdinandus This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with this program. If not, see . The full license text is in [LICENSE](LICENSE) — download it from and save it as `LICENSE` in the repository root. Both source files carry the corresponding notice at the top. NumPy, SciPy and Matplotlib are all BSD-licensed, so distributing this program under the GPL alongside them poses no conflict.