@@ -15,6 +15,10 @@ Two measurement modes are supported. **Beam deflection** fits both signals.
|
||||
there is no deflection: it fits the transmission alone, and needs only delay
|
||||
and transmission data.
|
||||
|
||||
The program also runs without a measurement. In **Simulation** mode nothing is
|
||||
imported: the signal is computed from the parameters alone, over a delay range
|
||||
entered by hand, and only the calculated curves are plotted and exported.
|
||||
|
||||

|
||||
|
||||
## Features
|
||||
@@ -27,10 +31,13 @@ and transmission data.
|
||||
parameter `rho`.
|
||||
- Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁,
|
||||
T₂) solved through the sample depth for a range of radial irradiances.
|
||||
- Side-by-side transmission and deflection plots with imported data overlaid.
|
||||
- Side-by-side transmission and deflection plots, with imported data overlaid
|
||||
when there is any.
|
||||
- Beam deflection and pump probe measurement modes. Pump probe reads a
|
||||
two-column delay/transmission scan, fixes the probe on the pump axis, and
|
||||
offers only the mechanisms that can change the transmission.
|
||||
- Fitting and simulation run modes. Simulation computes the signal with no
|
||||
data imported, over a delay range entered in the panel.
|
||||
- Optional diagnostic figures showing each mechanism's response function before
|
||||
and after convolution, plus the ESA populations and beam transmissions.
|
||||
- Export of the data/fit comparison, a full parameter log, and figures at
|
||||
@@ -62,18 +69,29 @@ python bd_fresnel_gui.py
|
||||
The window opens with the parameter panel on the left and three tabs on the
|
||||
right: **Fitting**, **Diagnostics**, and **Parameter log**.
|
||||
|
||||
A typical session:
|
||||
Fitting a measured scan:
|
||||
|
||||
1. Set the **Data columns** to match your file, and the delimiter.
|
||||
2. Choose the **Mode**: Beam deflection or Pump probe.
|
||||
1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**, and
|
||||
leave the second toggle on **Fitting**.
|
||||
2. Set the **Data columns** to match your file, and the delimiter.
|
||||
3. Press **Import…** and choose a scan. The plots show the measured data.
|
||||
4. Fill in the beam, material and geometry parameters, and configure one or
|
||||
more mechanisms with the **Params…** buttons.
|
||||
5. Press **Fit** to run the simulation and overlay it on the data.
|
||||
6. Press **Export…** to write the results.
|
||||
|
||||
**Fit** stays disabled until a file is imported, and **Export** until a fit has
|
||||
completed.
|
||||
Simulating without a measurement:
|
||||
|
||||
1. Under **Operation mode**, choose **Simulation**. **Import…** and the data
|
||||
column fields are disabled, and **Fit** becomes **Simulate**.
|
||||
2. Set `T_d_min` and `T_d_max` in **Simulation parameters** to the delay range
|
||||
to compute over. In Fitting mode these come from the imported file, so they
|
||||
are editable only here.
|
||||
3. Fill in the parameters and mechanisms as above.
|
||||
4. Press **Simulate**, then **Export…**.
|
||||
|
||||
**Fit** stays disabled until a file is imported; **Simulate** needs only valid
|
||||
parameters. **Export** stays disabled until a fit or simulation has completed.
|
||||
|
||||
Changing the mode, a column number or the delimiter re-reads the imported file.
|
||||
Any fit is discarded, since it belonged to the previous settings. If the file
|
||||
@@ -110,12 +128,14 @@ to split on any run of whitespace.
|
||||
| `DeltaEoE column` | `2` | Deflection data column |
|
||||
| `Delimiter` | `,` | Data column delimiter character |
|
||||
|
||||
### Mode
|
||||
### Operation mode
|
||||
|
||||
| Option | Effect |
|
||||
|-------------------|-------------------------------------------------|
|
||||
| `Beam deflection` | Transmission and deflection, offset probe |
|
||||
| `Pump probe` | Transmission only, centered probe |
|
||||
| `Fitting` | Compare the calculation against an imported scan |
|
||||
| `Simulation` | Calculate without a scan, over an entered range |
|
||||
|
||||
### Simulation parameters
|
||||
|
||||
@@ -126,6 +146,8 @@ to split on any run of whitespace.
|
||||
| `T_num` | `100` | Number of temporal points |
|
||||
| `T_max` | `5.0` | Range of temporal sampling (tau_p) |
|
||||
| `T_d_num` | `150` | Number of delay points over range |
|
||||
| `T_d_min` | `-5.0` | Delay range start (tau_p), Simulation only |
|
||||
| `T_d_max` | `5.0` | Delay range end (tau_p), Simulation only |
|
||||
|
||||
### Excitation beam parameters
|
||||
|
||||
@@ -201,7 +223,7 @@ Exporting to `<name>_fit.txt` also writes, in the same directory:
|
||||
|
||||
| File | Contents |
|
||||
| --- | --- |
|
||||
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only |
|
||||
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
|
||||
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
|
||||
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
|
||||
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
|
||||
@@ -210,10 +232,15 @@ Exporting to `<name>_fit.txt` also writes, in the same directory:
|
||||
|
||||
The last two appear only when *Show diagnostic plots during Fit* is ticked.
|
||||
|
||||
The log records enough to reproduce a run: data columns and delimiter, the
|
||||
mode, the simulation grid, every beam, material and geometry value, each
|
||||
mechanism with its parameters, and the derived quantities (`n_g`, `T_lin`,
|
||||
`z_0`, `I_0`, `rho`).
|
||||
In Simulation mode the export is named after the file you choose rather than an
|
||||
imported scan, and the table holds the calculated signals on their own delay
|
||||
grid, with no data columns to pair them with.
|
||||
|
||||
The log records enough to reproduce a run: both modes, the data columns and
|
||||
delimiter, the simulation grid including the delay range, every beam, material
|
||||
and geometry value, each mechanism with its parameters, and the derived
|
||||
quantities (`n_g`, `T_lin`, `z_0`, `I_0`, `rho`). In Simulation mode the import
|
||||
path and data column sections are omitted, having nothing to describe.
|
||||
|
||||