BD Fresnel

Beam-deflection pump–probe simulator and fitting tool. A Python port of the MATLAB BD_Fresnel_GUI suite.

The program models a weak probe beam crossing a sample that has been excited by a strong pump, propagates the perturbed probe field to a detector by Fresnel diffraction, and computes the transmission T and normalised beam deflection ΔE/E as a function of pump–probe delay. Measured scans can be imported and compared against the simulation, and the result exported as data, a log, and publication-sized figures.

Two measurement modes are supported. Beam deflection fits both signals. Pump probe is for measurements with the probe centred on the pump, where there is no deflection: it fits the transmission alone, and needs only delay and transmission data.

The program also runs without a measurement. In Simulation mode nothing is imported: the signal is computed from the parameters alone, over a delay range entered by hand, and only the calculated curves are plotted and exported.

BD Fresnel fitting a measured scan

Features

  • Seven mechanism slots, each independently configurable, summed into the total nonlinear response.
  • Instantaneous (electronic) and non-instantaneous responses, the latter convolved with the pulse envelope.
  • Group-velocity mismatch between pump and probe handled through the walk-off parameter rho.
  • Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁, T₂) solved through the sample depth for a range of radial irradiances.
  • Side-by-side transmission and deflection plots, with imported data overlaid when there is any.
  • Beam deflection and pump probe measurement modes. Pump probe reads a two-column delay/transmission scan, fixes the probe on the pump axis, and offers only the mechanisms that can change the transmission.
  • Fitting and simulation run modes. Simulation computes the signal with no data imported, over a delay range entered in the panel.
  • Optional diagnostic figures showing each mechanism's response function before and after convolution, plus the ESA populations and beam transmissions.
  • Export of the data/fit comparison, a full parameter log, and figures at 6.5 in / 300 dpi.

Requirements

  • Python 3.10 or newer (developed against 3.12)
  • numpy, scipy, matplotlib, mpmath
  • Tkinter, which ships with most Python builds. On Debian/Ubuntu it is a separate package:
sudo apt install python3-tk

Install the Python dependencies with:

pip install -r requirements.txt

Running

python bd_fresnel_gui.py

The window opens with the parameter panel on the left and three tabs on the right: Fitting, Diagnostics, and Parameter log.

Fitting a measured scan:

  1. Under Operation mode, choose Beam deflection or Pump probe, and leave the second toggle on Fitting.
  2. Set the Data columns to match your file, and the delimiter.
  3. Press Import… and choose a scan. The plots show the measured data.
  4. Fill in the beam, material and geometry parameters, and configure one or more mechanisms with the Params… buttons.
  5. Press Fit to run the simulation and overlay it on the data.
  6. Press Export… to write the results.

Simulating without a measurement:

  1. Under Operation mode, choose Simulation. Import… and the data column fields are disabled, and Fit becomes Simulate.
  2. Set T_d_min and T_d_max in Simulation parameters to the delay range to compute over. In Fitting mode these come from the imported file, so they are editable only here.
  3. Fill in the parameters and mechanisms as above.
  4. Press Simulate, then Export….

Fit stays disabled until a file is imported; Simulate needs only valid parameters. Export stays disabled until a fit or simulation has completed.

Changing the mode, a column number or the delimiter re-reads the imported file. Any fit is discarded, since it belonged to the previous settings. If the file cannot be read with the new settings, its data is cleared rather than left on screen, and it is read again once the settings allow.

Parameters are saved to last_settings.json beside the scripts when they change, and restored at the next launch. The data file itself is not restored.

Input data format

A delimited text file with one header line, then one row per delay point. Beam deflection needs three columns and pump probe two; which ones is set in the Data columns box, so extra columns can be present and ignored. Each quantity must come from a different column.

Quantity Units Default column Needed in
τ_d fs 1 both modes
ΔE/E fractional 2 Beam deflection only
T fractional (1.0 = no change) 3 both modes

The delimiter field takes a single character, \t for a tab, or is left blank to split on any run of whitespace.

Parameters

Data columns (1-indexed)

Variable Default Column contents
tau_d column 1 Delay column (fs)
T column 3 Transmission data column
DeltaEoE column 2 Deflection data column
Delimiter , Data column delimiter character

Operation mode

Option Effect
Beam deflection Transmission and deflection, offset probe
Pump probe Transmission only, centered probe
Fitting Compare the calculation against an imported scan
Simulation Calculate without a scan, over an entered range

Simulation parameters

Variable Default Column contents
X_num 50 Number of spatial points
X_max 5.0 Range of spatial sampling (w_0)
T_num 100 Number of temporal points
T_max 5.0 Range of temporal sampling (tau_p)
T_d_num 150 Number of delay points over range
T_d_min -5.0 Delay range start (tau_p), Simulation only
T_d_max 5.0 Delay range end (tau_p), Simulation only

Excitation beam parameters

Variable Default Column contents
E_p 1.36 Excitation pulse energy (uJ)
tau_p_FWHM 55.0 Excitation pulse duration (fs)
w_0p 246.0 Excitation beam waist (um)
lambda_p 800.0 Excitation pulse wavelength (nm)

Probe beam parameters

Variable Default Column contents
tau_FWHM 60.0 Probe pulse duration (fs)
w_0 43.0 Probe beam waist (um)
lambda 650.0 Probe pulse wavelength (nm)

Material parameters at excitation wavelength

Variable Default Column contents
R_p 0.0 Reflectivity
alpha_p 0.0 Linear absorption (cm^-1)
n_p 1.4533 Linear index
dndl_p -0.017284 First order dispersion (um^-1)
alpha_2d 0.0 2 photon absorption (e-11 m/W)

Material parameters at probe wavelength

Variable Default Column contents
R 0.0 Reflectivity
alpha 0.0 Linear absorption (cm^-1)
n 1.4565 Linear index
dndl -0.027158 First order dispersion (um^-1)

Measurement parameters

Variable Default Column contents
l 1.0 Sample thickness (mm)
d 15.0 Distance to detector (cm)
shift 0.0 Temporal shift (fs)
x_0 0.5 Displacement of probe (w_0p)

Mechanisms

Mechanism Parameters
Electronic (both) 2
Collisional (NLR) 3
Librational (NLR) 4
Reorientational (NLR) 3
Vibrational (NLR) 3
ESA – 3 level + triplet (both) 10
Exponential rise/decay (NLA) 3
Exponential rise/decay (NLR) 3
Exponential rise/decay (both) 4

NLR denotes a purely refractive response, NLA a purely absorptive one, and both a mechanism carrying each.

Pump probe offers only the NLA and both mechanisms: with the probe centred, a both mechanism contributes its absorptive part, and an NLR mechanism cannot change the transmission at all. Switching to Pump probe sets aside any NLR mechanism already chosen; switching back restores it, provided its slot is still empty.

Export output

Exporting to <name>_fit.txt also writes, in the same directory:

File Contents
<name>_fit.txt delay, data and fit for T, ΔE/E and Δn; in Pump probe, delay and T only. In Simulation, the calculated signals alone
<name>_fit_log.txt every parameter, plus a manifest of the files written
<name>_fit_combined.jpg / .svg transmission and deflection, 6.5 in at 300 dpi (Beam deflection)
<name>_fit_transmission.jpg / .svg transmission only, 3.25 in at 300 dpi (Pump probe)
<name>_fit_raw_response.jpg each mechanism's R[t] and A[t]
<name>_fit_convolved_response.jpg the same after convolution, plus the total

The last two appear only when Show diagnostic plots during Fit is ticked.

In Simulation mode the export is named after the file you choose rather than an imported scan, and the table holds the calculated signals on their own delay grid, with no data columns to pair them with.

The log records enough to reproduce a run: both modes, the data columns and delimiter, the simulation grid including the delay range, every beam, material and geometry value, each mechanism with its parameters, and the derived quantities (n_g, T_lin, z_0, I_0, rho). In Simulation mode the import path and data column sections are omitted, having nothing to describe.

Files

File Role
bd_fresnel_core.py physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies.
bd_fresnel_gui.py Tkinter interface, plotting, import/export, logging. Entry point.
set_params_dialog.py modal dialog for entering one mechanism's parameters.

References

Please cite the following when using results from this program.

  1. Reichert, M., et al. (2014). "Temporal, spectral, and polarization dependence of the nonlinear optical response of carbon disulfide." Optica 1(6): 436.
  2. Reichert, M., et al. (2014). "Temporal, spectral, and polarization dependence of the nonlinear optical response of carbon disulfide: supplementary material." Optica 1(6): 436.
  3. Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and polarization resolved ultrafast nonlinear refraction." Opt. Lett. 38(18): 3518–3521.

License

Copyright (C) 2019-2026 Manuel R. Ferdinandus

This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version.

This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

You should have received a copy of the GNU General Public License along with this program. If not, see https://www.gnu.org/licenses/.

NumPy, SciPy, Matplotlib and mpmath are all BSD-licensed, so distributing this program under the GPL alongside them poses no conflict.

S
Description
No description provided
Readme GPL-3.0
1.1 MiB
Languages
Python 100%