Update README.md
This commit is contained in:
@@ -4,11 +4,11 @@ Beam-deflection pump–probe simulator and fitting tool. A Python port of the
|
||||
MATLAB `BD_Fresnel_GUI` suite.
|
||||
|
||||
The program models a weak probe beam crossing a sample that has been excited by
|
||||
a strong pump, propagates the perturbed probe field to a detector by Fresnel
|
||||
diffraction, and computes the transmission `T` and normalised beam deflection
|
||||
`ΔE/E` as a function of pump–probe delay. Measured scans can be imported and
|
||||
compared against the simulation, and the result exported as data, a log, and
|
||||
publication-sized figures.
|
||||
a strong pump, propagates the perturbed probe field to the detector and computes
|
||||
the transmission `T` and normalised beam deflection `ΔE/E` as a function of
|
||||
pump–probe delay. Measured scans can be imported and compared against the
|
||||
simulation, and the result exported as data, a log, and publication-sized
|
||||
figures.
|
||||
|
||||
Two measurement modes are supported. **Beam deflection** fits both signals.
|
||||
**Pump probe** is for measurements with the probe centred on the pump, where
|
||||
@@ -159,8 +159,8 @@ the detector plane, then integrates each over time at every delay to get the
|
||||
energy difference `dE` and total `E`. The deflection is `dE/E` and the
|
||||
transmission is `E` normalised. With no spatial grid to size, `X_num` and
|
||||
`X_max` are greyed out; every other parameter, `Delta_n` included, is
|
||||
unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about
|
||||
**32x faster**.
|
||||
unaffected. On the four-layer graphene example it runs in 0.11 s against 3.65 s,
|
||||
about **32x faster**.
|
||||
|
||||
The trade-off is that `dP` is **first order in the nonlinear response**, where
|
||||
the Fresnel path keeps every order. The two therefore agree only while the
|
||||
@@ -173,11 +173,11 @@ phase is small, which the `eta (peak)` line of the parameter log reports:
|
||||
| 5.64 rad | 0.077 tau_e |
|
||||
| 14.1 rad | 0.36 tau_e |
|
||||
|
||||
Below roughly 1 rad the two are interchangeable, and the four-layer example sits
|
||||
at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a
|
||||
few rad the semi-analytical curve shifts noticeably and is no longer a
|
||||
substitute. Sample thickness, walk-off and pump absorption do not themselves
|
||||
affect the agreement once `eta (peak)` is held fixed.
|
||||
Below roughly 1 rad the two are interchangeable, and the four-layer graphene
|
||||
example sits at 0.049 rad with a correlation of 1.000000 and amplitudes within
|
||||
0.5%. Above a few rad the semi-analytical curve shifts noticeably and is no
|
||||
longer a substitute. Sample thickness, walk-off and pump absorption do not
|
||||
themselves affect the agreement once `eta (peak)` is held fixed.
|
||||
|
||||
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
|
||||
path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`
|
||||
|
||||
Reference in New Issue