Author SHA1 Message Date
manuel cb12b8cfc7 Update README.md 2026-09-12 20:30:39 +00:00
manuel 67dbda7c19 Merge pull request 'Add readme' (#1) from add_readme into main
Reviewed-on: #1
2026-09-12 20:27:44 +00:00
-22
View File
@@ -128,28 +128,6 @@ its parameters, and the derived quantities (`n_g`, `T_lin`, `z_0`, `I_0`,
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
## Notes on the port
The translation follows the MATLAB closely, including its array axis order, so
that intermediate results can be compared directly. Places where this port
deliberately differs are commented at the point of departure. The substantive
ones:
- **Physical constants** are taken from `scipy.constants` rather than
transcribed. The original hard-coded `c = 299797548` in `calc_beam_params`, a
digit transposition of the correct value used elsewhere in the same codebase,
and truncated Planck's constant to seven figures. Correcting the former
shifts `rho` by about 1.7 × 10⁻⁵ relative.
- **Delay-frame consistency**: the delay grid is derived from the shifted
`τ_d`, matching what the plots and export compare against. The original used
the unshifted values, a mismatch whenever `shift ≠ 0`.
- **Diagnostic instantaneous response**: the original's diagnostic plot used
`n_2e` where its four physics branches all used `2·n_2e`, so the plotted
electronic curve was half the simulated one. The plot now matches the
simulation.
- **Dialog close**: closing the parameter dialog with the window button is
treated as OK. In the original it left the caller's `uiwait` blocked forever.
## References
Please cite the following when using results from this program.