Files
BD_Fresnel_GUI/CHANGELOG.md
2026-11-16 17:40:21 +00:00

18 KiB

Changelog

All notable changes to BD Fresnel are documented in this file.

The format is based on Keep a Changelog.

[3.0] - 2026-11-14

Added

  • Semi-analytical algorithm, selectable from a third toggle in the Operation mode box alongside Fresnel propagation:

    • Instead of propagating the exit field to the detector by FFT, it uses closed-form expressions for the power difference and total at the detector, already integrated over the detector plane. Only an integral over time at each delay remains.
    • The time window runs +/- 5T about each delay, where T = tau_p/tau_e.
    • Transmission is the energy total normalised to its value before the pump arrives: the first delay point when fitting, and min(-3 rho, -3) tau_e when simulating, so a thin sample with rho -> 0 still normalises away from the peak.
    • X_num and X_max are disabled in this mode: the expressions are already integrated over space, so there is no spatial grid.
    • Applies to both measurement modes. In pump probe the probe is centred, x_0 = 0, so the deflection term vanishes identically and the transmission alone is calculated.
    • Both algorithms are kept so results can be compared. Switching discards the current result, which belongs to the other method.
    • The algorithm is saved with the other settings and recorded in the parameter log.
    • The absorptive term in the deflection expression carries a PROVISIONAL coefficient, SA_ABSORPTIVE_FACTOR. As derived, that term matched neither the sign nor the magnitude of the Fresnel result: a purely absorptive mechanism disagreed by a factor of about -69, with correlation exactly -1. Dividing by D = d / (pi w_0_p^2 / lambda_p) = d / z_0_p accounts for the distance and wavelength dependence exactly, and is independent of sample thickness at constant alpha_2_exp*l; the remaining -1/(1 + 2W^2) was measured against the Fresnel path rather than derived. With it the two methods agree to 0.5% for mechanisms with a refractive part and 4.5% for purely absorptive ones. It is isolated in one function pending a corrected derivation.
  • The parameter log's Calculated Parameters (pump) section reports sigma_e, the normalised pump linear absorption alpha_e * L / 2. It sits next to T_lin, which restates it: with no pump two-photon absorption T_lin = (1 - R_p) exp(-2 sigma_e). Read from the parameters rather than the result, so it is reported for either algorithm.

  • The Other panel and the parameter log's Other section both report eta (peak) and Gamma (peak), the largest nonlinear phase and absorption exponent anywhere on the grid, from whichever algorithm produced the result. These are the only readouts in those panels that come from the result rather than from the parameters, since they are peaks over the whole (T, T_d) grid and cannot be had without running the calculation. They therefore show -- until a Fit or Simulate completes, and return to -- whenever that result is discarded, so a stale phase is never displayed beside freshly edited parameters. eta (peak) is the yardstick for the semi-analytical algorithm's validity: its dP is first order in the response while Fresnel propagation keeps every order, so the two agree only while the phase is small. On the 4-layer mechanisms the peak of DeltaEoE sits at the same delay to within 0.0003 tau_e at eta (peak) = 0.14, but 0.0035 at 1.41, 0.077 at 5.6 and 0.36 at 14.1. Holding eta (peak) fixed, the agreement is unaffected by sample thickness (0.05 to 2 mm), by walk-off (rho 0.04 to 1.7) and by pump absorption (sigma_e 0 to 10), so this one number sets the regime. Both algorithms report it to within 2e-5 of each other.

Changed

  • Both beams are now explicitly subscripted: the pump carries _e (excitation) and the probe carries _p. This restores the convention the original MATLAB used, which the Python port had partly inverted (_p for the pump) and partly dropped (no suffix for the probe). No beam quantity is unsubscripted any more; the only unsuffixed parameters left are the ones belonging to neither beam -- the sampling grid, the sample geometry (l, d, shift), the relative offset x_0, and the walk-off rho.

    pump: was now probe: was now
    E_p E_e tau_FWHM tau_p_FWHM
    tau_p_FWHM tau_e_FWHM w_0 w_0_p
    w_0p w_0_e lambda_ lambda_p
    lambda_p lambda_e R R_p
    R_p R_e alpha alpha_p
    alpha_p alpha_e n n_p
    n_p n_e dndl dndl_p
    dndl_p dndl_e tau tau_p
    alpha_2d alpha_2d_e ng ng_p
    tau_p tau_e z_0 z_0_p
    sigma_p sigma_e Tlin Tlin_p
    I_0_p I_0_e
    ng_p ng_e
    z_0_p z_0_e
    Tlin_p Tlin_e
    sigma_p2 / sigma_p20 sigma_e2 / sigma_e20
    a_p_0, W_0_p, I_p_pulse a_e_0, W_0_e, I_e_pulse

    Note that six probe names -- tau_p_FWHM, lambda_p, R_p, alpha_p, n_p, dndl_p -- are spelled exactly like what were pump names before this release. Reading an old log or settings file alongside a new one needs care; see the settings note below for how the program itself is protected.

    The pump pass renamed 389 identifier occurrences textually; the probe pass was done by rewriting 116 exact AST node positions instead, because n, R, alpha and tau are overloaded in this codebase (lambda parameters, the author's initials in the copyright line, the semi-analytical formula's geometric R, a diagnostics dict key) and no text pattern distinguishes them.

    was now was now
    E_p E_e tau_p tau_e
    tau_p_FWHM tau_e_FWHM sigma_p sigma_e
    w_0p w_0_e I_0_p I_0_e
    lambda_p lambda_e ng_p ng_e
    R_p R_e z_0_p z_0_e
    alpha_p alpha_e Tlin_p Tlin_e
    n_p n_e sigma_p2 sigma_e2
    dndl_p dndl_e sigma_p20 sigma_e20
    alpha_2d alpha_2d_e a_p_0 a_e_0

    w_0p gains the separating underscore it was missing, so the field name finally matches the variable that held it (w_0_p) and its siblings z_0_e and I_0_e. alpha_2d_e keeps the d for degenerate.

  • The Electronic mechanism's parameters are renamed alpha_2e -> alpha_2el and n_2e -> n_2el, since their e meant electronic and would otherwise collide with _e for excitation -- the pump's degenerate two-photon coefficient would have wanted the name alpha_2e, which was taken. _e now means excitation and nothing else.

  • BD_3_level_triplet, I_e_func and excite_prop needed no renaming at all: transliterated from the MATLAB, they already used _e for the pump and _p for the probe, so n_g_p, v_p and I_p inside them were correct all along. With both beams now subscribed to that convention, the whole file reads against the MATLAB without translation.

  • last_settings.json written by an earlier version is now refused rather than misread. Saved settings carry a settings_schema stamp, and a file without the current one is rejected with a message explaining why. This is not housekeeping: because six probe field names are spelled exactly like former pump keys, loading an old file by name alone would have installed the pump's wavelength, index, reflectivity, absorption and dispersion as the probe's -- every number plausible, every result wrong. Re-enter the parameters once and they save in the new layout. Any other unrecognised key is still dropped with a note on stderr.

  • Log and panel labels follow their fields on both sides: n_g_e, sigma_e, T_lin_e, z_0_e, I_0_e for the pump and n_g_p, T_lin_p, z_0_p for the probe, with the beam parameters and material blocks likewise. The GUI's pump calculated-parameters panel also gains a sigma_e readout, which it had not displayed before.

  • T_lin_p and T_lin_e are labelled T_lin_p (transmission) and T_lin_e (transmission) in both the panel and the log, so the quantity is named and not just abbreviated. The log's value column moved from 25 to 29 to fit them, and the panel's label column from 20 to 23 characters -- which also squares up z_0_p (Rayleigh range), z_0_e (Rayleigh range) and I_0_e (peak irradiance), all of which had been overrunning the old 20 and pushing their own values out of line.

  • The rename is numerically inert: across 8 mechanism types x 2 algorithms x 3 pump-absorption configurations (49 cases, 3275 values), DeltaEoE, T, Delta_n, eta_peak and Gamma_peak are bit-identical to the pre-rename code, and pyflakes reports zero warnings before and after.

  • Transmission y-axis tick labels are limited to three significant digits, so "99.75" reads "99.8". The count is a floor rather than a cap: a shallow scan spanning a few hundredths of a percent would round every tick to "100", so digits are added only where that would happen. The deflection axis is unaffected.

  • The reference list in the README and the parameter log follows Optica style: every author listed, initials first, abbreviated journal, volume, full page range, year. Author lists and page ranges were checked against the published papers.

  • The duplicate supplementary-material citation is dropped, leaving two references.

  • The parameter log is written as UTF-8. The citations use typographic quotes and an en dash, which the locale's encoding cannot always represent.

Fixed

  • The instantaneous (Electronic) response for a sample with both walk-off and pump absorption is evaluated through the scaled complementary error function erfcx instead of the form in BD_Fresnel_func_ni.m. That form multiplied exp(sigma_e^2/rho^2 + 2 sigma_e u/rho) by a difference of error functions falling to zero, so the product was lost to cancellation well before it overflowed: at rho = 0.4336 (l = 0.5 mm) it was already wrong over 8.6% of the delay axis at sigma_e = 2.5 (alpha_e = 100 cm^-1), returning exactly 0.0 with no NaN to signal it, and returned NaN above sigma_e = 3. The usable ceiling on alpha_e for an Electronic mechanism at that thickness was therefore about 60 cm^-1, not the ~120 where NaN first appeared. The rearrangement is algebraic, with every surviving exponent non-positive; it reproduces the original evaluated at 600 decimal digits to 1e-16..3e-13 relative over sigma_e = 0.25 to 10 and u = -3 to 18, both where the original works and where it does not.
  • Pump absorption is applied to non-instantaneous mechanisms when the walk-off is exactly zero. Substituting T1 = (T+T_d) - rho + rho*zeta shows the rho != 0 branch to be a depth average over atten_fac, whose rho -> 0 limit is the response at one instant times the mean of atten_fac; the original used the bare response. The dropped factor is (1 - exp(-2 sigma_e))/(2 sigma_e) for linear pump absorption, so the response was previously independent of alpha_e altogether in this case -- identical at alpha_e = 0 and 200 cm^-1. It was 1.27x too large at alpha_e = 10 cm^-1 and l = 0.5 mm, and 10x at 200 cm^-1. The two branches now agree to nine digits across rho = 0. This affects only samples with ng_p exactly equal to ng_e (for example no dispersion entered at either wavelength) and non-zero pump absorption; with alpha_e = alpha_2d_e = 0 the mean is exactly 1 and results are bit-identical to before.
  • Pump absorption through the sample depth, atten_fac, is computed from the closed-form solution of dI_e/dz = -alpha_e I_e - alpha_2d_e I_e^2 rather than the two-branch expression carried over from BD_Fresnel_func_ni.m. That expression's pump two-photon branch, sqrt((B1 B2)/sigma_e), failed three ways: it did not reduce to its own sigma_e2 == 0 branch as alpha_2d_e -> 0 (it decayed at half the correct rate), it divided by zero whenever alpha_e was zero, and it took the square root of a negative number whenever sigma_e20 > sigma_e. The net effect was that every run combining a non-zero alpha_2d_e with a non-instantaneous mechanism returned NaN at every delay -- pump two-photon absorption worked only for the Electronic mechanism, which does not use atten_fac. Dropping the stray square root recovers that expression as the linearisation of the exact one in sigma_e20, which is how the intent was identified. Results for alpha_2d_e = 0 are bit-identical to before; the new form agrees with numerical integration of the pump propagation equation to 2e-12 relative over sigma_e and sigma_e20 from 0 to 20, including both limits.
  • A negative alpha_2d_e large enough to make the pump diverge inside the sample (two-photon gain, no finite depth average) is now refused with a message naming the largest |alpha_2d_e| that works for the current thickness and pump irradiance, rather than silently returning a meaningless attenuation of order 1e12.
  • mpmath is imported only where it is used, in the pump two-photon absorption term. Importing it at module level made an optional dependency fatal at startup, so the program would not run at all without it. If that term is ever reached without mpmath installed, the error now says which package is missing and why.

[2.6] - 2026-09-30

Added

  • Simulation run mode: a second toggle in the Operation mode box, offering Fitting and Simulation. Fitting is the default and behaves as before.
  • Simulation mode, for computing a signal without a measurement:
    • No file is imported. Import... and the data column and delimiter fields are disabled.
    • The delay range is entered as T_d_min and T_d_max (in tau_p) in the Simulation parameters box. In Fitting mode these are taken from the imported scan and the fields are disabled.
    • Only the calculated curves are plotted, without data markers, and the plot legend reads Simulated rather than Fit.
    • The Fit button is relabelled Simulate, and is enabled by valid parameters alone rather than by an imported file.
    • The export holds the calculated signals on their own delay grid, with no data columns to pair them with. The parameter log omits the import path and the data column section.
    • The mode combines with the measurement mode: Pump probe and Simulation together give a single Transmission panel and a two-column table, as Pump probe does when fitting.
  • The run mode is saved with the other settings and recorded in the parameter log.

Changed

  • The Mode box is renamed Operation mode and moved to the top of the parameter panel, above Data columns. The parameter log and status messages use the new name, and the log records both modes on one line.
  • Changing run mode discards the current result, which described the other mode's delay range or a measurement the new mode does not show. Switching to Simulation sets the imported scan aside and switching back reloads it. The run mode cannot be changed while a fit runs.
  • inputs_valid takes a require_data argument, so Simulation can enable its action button without an imported file. Fitting is unaffected.

[2.5] - 2026-09-21

Added

  • Mode box, below Data columns: a two-button toggle selecting Beam deflection or Pump probe. Beam deflection is the default and behaves as before.
  • Pump probe mode, for measurements with the probe centred on the pump:
    • Only the delay and transmission columns are required, so a two-column scan can be imported. The DeltaEoE column is ignored and its field disabled.
    • x_0 is fixed at 0 and cannot be edited.
    • Only the Transmission plot is displayed and exported. The exported image is named <name>_fit_transmission.jpg / .svg and is 3.25 in wide, a single column. The exported data table holds delay, T (data) and T (fit).
    • The mechanism pull-downs offer the absorptive (NLA) and mixed (both) mechanisms; a mixed mechanism contributes its absorptive part. The purely refractive (NLR) mechanisms, which cannot change the transmission, are excluded. Switching to pump probe empties any slot holding one; switching back restores it, provided the slot is still empty.
  • The selected mode is saved with the other settings and recorded in the parameter log.

Changed

  • Changing mode discards the current fit, which was computed with the other mode's settings, and re-reads the imported file under the new mode's column requirements. A file the new mode cannot use is cleared with an explanation, and loaded again on switching back. The mode cannot be changed while a fit runs.
  • The source files carry the GPLv3 notice.

Fixed

  • Values such as nan, inf or 1e999 are rejected in parameter fields. They previously turned the fit to NaN, and crashed the mechanism parameters dialog.
  • An invalid entry in a numeric field reverts to its previous value, as the integer fields and the mechanism dialog already did, instead of becoming 0.
  • Every parameter change is saved as it is made. Numeric fields, mechanism choices and the diagnostics option were previously saved only on Import, Fit, Export or Exit, so a crash lost them.
  • Changing a column number or the delimiter re-reads only a file imported in the current session. Straight after launch it could load the previous session's file, or report an error about one that had since moved.
  • When a file cannot be read with a new column number or delimiter, its data and fit are cleared. They previously stayed on screen, and could be exported, under settings that no longer described them.
  • The data columns in use must each be different. Two quantities could previously be read from the same column without any warning.
  • The x tick label at the join between the Transmission and Deflection plots is hidden when it collides with its neighbour. A rounding error let some such labels through.

[2.4] - 2026-09-21

First release recorded in this changelog. Earlier history is not documented here.

Fixed

  • README parameter tables corrected to match the program's window: the default T and DeltaEoE data columns were swapped, and several defaults, labels and descriptions disagreed with what the interface shows.