78 lines
3.2 KiB
Markdown
78 lines
3.2 KiB
Markdown
# Changelog
|
|
|
|
All notable changes to BD Fresnel are documented in this file.
|
|
|
|
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
|
|
|
## [Unreleased]
|
|
|
|
## [2.5] - 2026-09-21
|
|
|
|
### Added
|
|
|
|
- **Mode** box, below Data columns: a two-button toggle selecting
|
|
**Beam deflection** or **Pump probe**. Beam deflection is the default
|
|
and behaves as before.
|
|
- Pump probe mode, for measurements with the probe centred on the pump:
|
|
- Only the delay and transmission columns are required, so a
|
|
two-column scan can be imported. The DeltaEoE column is ignored and
|
|
its field disabled.
|
|
- `x_0` is fixed at 0 and cannot be edited.
|
|
- Only the Transmission plot is displayed and exported. The exported
|
|
image is named `<name>_fit_transmission.jpg` / `.svg` and is 3.25 in
|
|
wide, a single column. The exported data table holds delay, T (data)
|
|
and T (fit).
|
|
- The mechanism pull-downs offer the absorptive (NLA) and mixed
|
|
(both) mechanisms; a mixed mechanism contributes its absorptive
|
|
part. The purely refractive (NLR) mechanisms, which cannot change
|
|
the transmission, are excluded. Switching to pump probe empties any
|
|
slot holding one; switching back restores it, provided the slot is
|
|
still empty.
|
|
- The selected mode is saved with the other settings and recorded in the
|
|
parameter log.
|
|
|
|
### Changed
|
|
|
|
- Changing mode discards the current fit, which was computed with the
|
|
other mode's settings, and re-reads the imported file under the new
|
|
mode's column requirements. A file the new mode cannot use is cleared
|
|
with an explanation, and loaded again on switching back. The mode
|
|
cannot be changed while a fit runs.
|
|
|
|
### Fixed
|
|
|
|
- Values such as `nan`, `inf` or `1e999` are rejected in parameter fields.
|
|
They previously turned the fit to NaN, and crashed the mechanism
|
|
parameters dialog.
|
|
- An invalid entry in a numeric field reverts to its previous value, as the
|
|
integer fields and the mechanism dialog already did, instead of becoming 0.
|
|
- Every parameter change is saved as it is made. Numeric fields, mechanism
|
|
choices and the diagnostics option were previously saved only on Import,
|
|
Fit, Export or Exit, so a crash lost them.
|
|
- Changing a column number or the delimiter re-reads only a file imported in
|
|
the current session. Straight after launch it could load the previous
|
|
session's file, or report an error about one that had since moved.
|
|
- When a file cannot be read with a new column number or delimiter, its data
|
|
and fit are cleared. They previously stayed on screen, and could be
|
|
exported, under settings that no longer described them.
|
|
- The data columns in use must each be different. Two quantities could
|
|
previously be read from the same column without any warning.
|
|
- The x tick label at the join between the Transmission and Deflection plots
|
|
is hidden when it collides with its neighbour. A rounding error let some
|
|
such labels through.
|
|
|
|
### Changed
|
|
|
|
- The source files carry the GPLv3 notice.
|
|
|
|
## [2.4] - 2026-09-21
|
|
|
|
First release recorded in this changelog. Earlier history is not documented
|
|
here.
|
|
|
|
### Fixed
|
|
|
|
- README parameter tables corrected to match the program's window: the
|
|
default T and DeltaEoE data columns were swapped, and several defaults,
|
|
labels and descriptions disagreed with what the interface shows.
|