BD Fresnel
Beam-deflection pump–probe simulator and fitting tool. A Python port of the
MATLAB BD_Fresnel_GUI suite.
The program models a weak probe beam crossing a sample that has been excited by
a strong pump, propagates the perturbed probe field to a detector by Fresnel
diffraction, and computes the transmission T and normalised beam deflection
ΔE/E as a function of pump–probe delay. Measured scans can be imported and
compared against the simulation, and the result exported as data, a log, and
publication-sized figures.
Two measurement modes are supported. Beam deflection fits both signals. Pump probe is for measurements with the probe centred on the pump, where there is no deflection: it fits the transmission alone, and needs only delay and transmission data.
The program also runs without a measurement. In Simulation mode nothing is imported: the signal is computed from the parameters alone, over a delay range entered by hand, and only the calculated curves are plotted and exported.
Features
- Seven mechanism slots, each independently configurable, summed into the total nonlinear response.
- Instantaneous (electronic) and non-instantaneous responses, the latter convolved with the pulse envelope.
- Group-velocity mismatch between pump and probe handled through the walk-off
parameter
rho. - Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁, T₂) solved through the sample depth for a range of radial irradiances.
- Side-by-side transmission and deflection plots, with imported data overlaid when there is any.
- Beam deflection and pump probe measurement modes. Pump probe reads a two-column delay/transmission scan, fixes the probe on the pump axis, and offers only the mechanisms that can change the transmission.
- Fitting and simulation run modes. Simulation computes the signal with no data imported, over a delay range entered in the panel.
- Two interchangeable algorithms. Fresnel propagation carries the exit field to the detector by FFT; the semi-analytical method uses closed-form detector power expressions instead, needing no spatial grid and running about 32x faster, at the cost of holding only to first order in the nonlinear response.
- Optional diagnostic figures showing each mechanism's response function before and after convolution, plus the ESA populations and beam transmissions.
- Export of the data/fit comparison, a full parameter log, and figures at 6.5 in / 300 dpi.
Requirements
- Python 3.10 or newer (developed against 3.12)
numpy,scipy,matplotlib,mpmath- Tkinter, which ships with most Python builds. On Debian/Ubuntu it is a separate package:
sudo apt install python3-tk
Install the Python dependencies with:
pip install -r requirements.txt
Running
python bd_fresnel_gui.py
The window opens with the parameter panel on the left and three tabs on the right: Fitting, Diagnostics, and Parameter log.
Fitting a measured scan:
- Under Operation mode, choose Beam deflection or Pump probe, leave the second toggle on Fitting, and pick an algorithm on the third: Fresnel propagation or the faster Semi-analytical.
- Set the Data columns to match your file, and the delimiter.
- Press Import… and choose a scan. The plots show the measured data.
- Fill in the beam, material and geometry parameters, and configure one or more mechanisms with the Params… buttons.
- Press Fit to run the simulation and overlay it on the data.
- Press Export… to write the results.
Simulating without a measurement:
- Under Operation mode, choose Simulation. Import… and the data column fields are disabled, and Fit becomes Simulate. The algorithm toggle works the same way as in Fitting mode.
- Set
T_d_minandT_d_maxin Simulation parameters to the delay range to compute over. In Fitting mode these come from the imported file, so they are editable only here. - Fill in the parameters and mechanisms as above.
- Press Simulate, then Export….
Fit stays disabled until a file is imported; Simulate needs only valid parameters. Export stays disabled until a fit or simulation has completed.
Changing the mode, a column number or the delimiter re-reads the imported file. Any fit is discarded, since it belonged to the previous settings. If the file cannot be read with the new settings, its data is cleared rather than left on screen, and it is read again once the settings allow.
Parameters are saved to last_settings.json beside the scripts when they
change, and restored at the next launch. The data file itself is not restored.
Input data format
A delimited text file with one header line, then one row per delay point. Beam deflection needs three columns and pump probe two; which ones is set in the Data columns box, so extra columns can be present and ignored. Each quantity must come from a different column.
| Quantity | Units | Default column | Needed in |
|---|---|---|---|
τ_d |
fs | 1 | both modes |
ΔE/E |
fractional | 2 | Beam deflection only |
T |
fractional (1.0 = no change) | 3 | both modes |
The delimiter field takes a single character, \t for a tab, or is left blank
to split on any run of whitespace.
Parameters
Data columns (1-indexed)
| Variable | Default | Column contents |
|---|---|---|
tau_d column |
1 |
Delay column (fs) |
T column |
3 |
Transmission data column |
DeltaEoE column |
2 |
Deflection data column |
Delimiter |
, |
Data column delimiter character |
Operation mode
Three independent toggles. Any combination is valid.
| Toggle | Option | Effect |
|---|---|---|
| Measurement | Beam deflection |
Transmission and deflection, offset probe |
Pump probe |
Transmission only, centered probe | |
| Run | Fitting |
Compare the calculation against an imported scan |
Simulation |
Calculate without a scan, over an entered range | |
| Algorithm | Fresnel propagation |
Propagate the exit field to the detector by FFT |
Semi-analytical |
Closed-form detector power, no spatial grid |
Algorithm
Fresnel propagation is the original method. The field at the exit face is built on an (x, y) grid, propagated to the detector by FFT, and integrated over the detector halves to get the power difference and total at each instant.
Semi-analytical skips the propagation. It evaluates closed-form expressions
for the detector power difference dP and total P, already integrated over
the detector plane, then integrates each over time at every delay to get the
energy difference dE and total E. The deflection is dE/E and the
transmission is E normalised. With no spatial grid to size, X_num and
X_max are greyed out; every other parameter, Delta_n included, is
unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about
32x faster.
The trade-off is that dP is first order in the nonlinear response, where
the Fresnel path keeps every order. The two therefore agree only while the
phase is small, which the eta (peak) line of the parameter log reports:
eta (peak) |
Peak of DeltaEoE displaced by |
|---|---|
| 0.14 rad | 0.0003 tau_e |
| 1.41 rad | 0.0035 tau_e |
| 5.64 rad | 0.077 tau_e |
| 14.1 rad | 0.36 tau_e |
Below roughly 1 rad the two are interchangeable, and the four-layer example sits
at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a
few rad the semi-analytical curve shifts noticeably and is no longer a
substitute. Sample thickness, walk-off and pump absorption do not themselves
affect the agreement once eta (peak) is held fixed.
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
path attenuates by exp(-2 a_e^2 Gamma) across the probe profile, where a_e
is the pump amplitude profile, while the semi-analytical form uses the on-axis
exp(-2 x_0^2).
One coefficient in dP's absorptive term, SA_ABSORPTIVE_FACTOR, is at present
fitted against the Fresnel path rather than derived. It is isolated in a single
function in bd_fresnel_core.py, with the measurements behind it recorded
there.
The transmission needs a reference delay, taken from before the pump arrives.
In Fitting mode it is the first delay point of the imported scan; in
Simulation mode it is min(-3 rho, -3) tau_e, which follows the walk-off
when that is the larger scale and is three pulse widths otherwise, so a thin
sample still normalises away from the peak.
Simulation parameters
| Variable | Default | Column contents |
|---|---|---|
X_num |
50 |
Number of spatial points, Fresnel only |
X_max |
5.0 |
Range of spatial sampling (w_0_p), Fresnel only |
T_num |
100 |
Number of temporal points |
T_max |
5.0 |
Range of temporal sampling (tau_e) |
T_d_num |
150 |
Number of delay points over range |
T_d_min |
-5.0 |
Delay range start (tau_e), Simulation only |
T_d_max |
5.0 |
Delay range end (tau_e), Simulation only |
X_num and X_max size the spatial grid the Fresnel method propagates, so the
semi-analytical method greys them out.
Excitation beam parameters
| Variable | Default | Column contents |
|---|---|---|
E_e |
1.36 |
Excitation pulse energy (uJ) |
tau_e_FWHM |
55.0 |
Excitation pulse duration (fs) |
w_0_e |
246.0 |
Excitation beam waist (um) |
lambda_e |
800.0 |
Excitation pulse wavelength (nm) |
Probe beam parameters
| Variable | Default | Column contents |
|---|---|---|
tau_p_FWHM |
60.0 |
Probe pulse duration (fs) |
w_0_p |
43.0 |
Probe beam waist (um) |
lambda_p |
650.0 |
Probe pulse wavelength (nm) |
Material parameters at excitation wavelength
| Variable | Default | Column contents |
|---|---|---|
R_e |
0.0 |
Reflectivity |
alpha_e |
0.0 |
Linear absorption (cm^-1) |
n_e |
1.4533 |
Linear index |
dndl_e |
-0.017284 |
First order dispersion (um^-1) |
alpha_2d_e |
0.0 |
2 photon absorption (e-11 m/W) |
Material parameters at probe wavelength
| Variable | Default | Column contents |
|---|---|---|
R_p |
0.0 |
Reflectivity |
alpha_p |
0.0 |
Linear absorption (cm^-1) |
n_p |
1.4565 |
Linear index |
dndl_p |
-0.027158 |
First order dispersion (um^-1) |
Measurement parameters
| Variable | Default | Column contents |
|---|---|---|
l |
1.0 |
Sample thickness (mm) |
d |
15.0 |
Distance to detector (cm) |
shift |
0.0 |
Temporal shift (fs) |
x_0 |
0.5 |
Displacement of probe (w_0_e) |
Mechanisms
| Mechanism | Parameters |
|---|---|
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
NLR denotes a purely refractive response, NLA a purely absorptive one, and
both a mechanism carrying each.
Pump probe offers only the NLA and both mechanisms: with the probe centred,
a both mechanism contributes its absorptive part, and an NLR mechanism
cannot change the transmission at all. Switching to Pump probe sets aside any
NLR mechanism already chosen; switching back restores it, provided its slot
is still empty.
Export output
Exporting to <name>_fit.txt also writes, in the same directory:
| File | Contents |
|---|---|
<name>_fit.txt |
delay, data and fit for T, ΔE/E and Δn; in Pump probe, delay and T only. In Simulation, the calculated signals alone |
<name>_fit_log.txt |
every parameter, plus a manifest of the files written |
<name>_fit_combined.jpg / .svg |
transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
<name>_fit_transmission.jpg / .svg |
transmission only, 3.25 in at 300 dpi (Pump probe) |
<name>_fit_raw_response.jpg |
each mechanism's R[t] and A[t] |
<name>_fit_convolved_response.jpg |
the same after convolution, plus the total |
The last two appear only when Show diagnostic plots during Fit is ticked.
In Simulation mode the export is named after the file you choose rather than an imported scan, and the table holds the calculated signals on their own delay grid, with no data columns to pair them with.
The log records enough to reproduce a run: both modes, the data columns and
delimiter, the simulation grid including the delay range, every beam, material
and geometry value, each mechanism with its parameters, and the derived
quantities (n_g, T_lin, z_0, I_0, rho). In Simulation mode the import
path and data column sections are omitted, having nothing to describe.
Files
| File | Role |
|---|---|
bd_fresnel_core.py |
physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
bd_fresnel_gui.py |
Tkinter interface, plotting, import/export, logging. Entry point. |
set_params_dialog.py |
modal dialog for entering one mechanism's parameters. |
References
Please cite the following when using results from this program.
- M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, T. R. Ensley, D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and E. W. Van Stryland, “Temporal, spectral, and polarization dependence of the nonlinear optical response of carbon disulfide,” Optica 1, 436–445 (2014).
- M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and E. W. Van Stryland, “Beam deflection measurement of time and polarization resolved ultrafast nonlinear refraction,” Opt. Lett. 38, 3518–3521 (2013).
License
Copyright (C) 2019-2026 Manuel R. Ferdinandus
This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with this program. If not, see https://www.gnu.org/licenses/.
NumPy, SciPy, Matplotlib and mpmath are all BSD-licensed, so distributing this program under the GPL alongside them poses no conflict.