Files
BD_Fresnel_GUI/CHANGELOG.md
T
2026-09-23 01:15:43 +00:00

3.2 KiB

Changelog

All notable changes to BD Fresnel are documented in this file.

The format is based on Keep a Changelog.

[Unreleased]

[2.5] - 2026-09-21

Added

  • Mode box, below Data columns: a two-button toggle selecting Beam deflection or Pump probe. Beam deflection is the default and behaves as before.
  • Pump probe mode, for measurements with the probe centred on the pump:
    • Only the delay and transmission columns are required, so a two-column scan can be imported. The DeltaEoE column is ignored and its field disabled.
    • x_0 is fixed at 0 and cannot be edited.
    • Only the Transmission plot is displayed and exported. The exported image is named <name>_fit_transmission.jpg / .svg and is 3.25 in wide, a single column. The exported data table holds delay, T (data) and T (fit).
    • The mechanism pull-downs offer the absorptive (NLA) and mixed (both) mechanisms; a mixed mechanism contributes its absorptive part. The purely refractive (NLR) mechanisms, which cannot change the transmission, are excluded. Switching to pump probe empties any slot holding one; switching back restores it, provided the slot is still empty.
  • The selected mode is saved with the other settings and recorded in the parameter log.

Changed

  • Changing mode discards the current fit, which was computed with the other mode's settings, and re-reads the imported file under the new mode's column requirements. A file the new mode cannot use is cleared with an explanation, and loaded again on switching back. The mode cannot be changed while a fit runs.

Fixed

  • Values such as nan, inf or 1e999 are rejected in parameter fields. They previously turned the fit to NaN, and crashed the mechanism parameters dialog.
  • An invalid entry in a numeric field reverts to its previous value, as the integer fields and the mechanism dialog already did, instead of becoming 0.
  • Every parameter change is saved as it is made. Numeric fields, mechanism choices and the diagnostics option were previously saved only on Import, Fit, Export or Exit, so a crash lost them.
  • Changing a column number or the delimiter re-reads only a file imported in the current session. Straight after launch it could load the previous session's file, or report an error about one that had since moved.
  • When a file cannot be read with a new column number or delimiter, its data and fit are cleared. They previously stayed on screen, and could be exported, under settings that no longer described them.
  • The data columns in use must each be different. Two quantities could previously be read from the same column without any warning.
  • The x tick label at the join between the Transmission and Deflection plots is hidden when it collides with its neighbour. A rounding error let some such labels through.

Changed

  • The source files carry the GPLv3 notice.

[2.4] - 2026-09-21

First release recorded in this changelog. Earlier history is not documented here.

Fixed

  • README parameter tables corrected to match the program's window: the default T and DeltaEoE data columns were swapped, and several defaults, labels and descriptions disagreed with what the interface shows.