# Changelog
All notable changes to BD Fresnel are documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
## [Unreleased]
## [2.5] - 2026-09-21
### Added
- **Mode** box, below Data columns: a two-button toggle selecting
**Beam deflection** or **Pump probe**. Beam deflection is the default
and behaves as before.
- Pump probe mode, for measurements with the probe centred on the pump:
- Only the delay and transmission columns are required, so a
two-column scan can be imported. The DeltaEoE column is ignored and
its field disabled.
- `x_0` is fixed at 0 and cannot be edited.
- Only the Transmission plot is displayed and exported. The exported
image is named `<name>_fit_transmission.jpg` / `.svg` and is 3.25 in
wide, a single column. The exported data table holds delay, T (data)
and T (fit).
- The mechanism pull-downs offer the absorptive (NLA) and mixed
(both) mechanisms; a mixed mechanism contributes its absorptive
part. The purely refractive (NLR) mechanisms, which cannot change
the transmission, are excluded. Switching to pump probe empties any
slot holding one; switching back restores it, provided the slot is
still empty.
- The selected mode is saved with the other settings and recorded in the
parameter log.
### Changed
- Changing mode discards the current fit, which was computed with the
other mode's settings, and re-reads the imported file under the new
mode's column requirements. A file the new mode cannot use is cleared
with an explanation, and loaded again on switching back. The mode
cannot be changed while a fit runs.
### Fixed
- Values such as `nan`, `inf` or `1e999` are rejected in parameter fields.
They previously turned the fit to NaN, and crashed the mechanism
parameters dialog.
- An invalid entry in a numeric field reverts to its previous value, as the
integer fields and the mechanism dialog already did, instead of becoming 0.
- Every parameter change is saved as it is made. Numeric fields, mechanism
choices and the diagnostics option were previously saved only on Import,
Fit, Export or Exit, so a crash lost them.
- Changing a column number or the delimiter re-reads only a file imported in
the current session. Straight after launch it could load the previous
session's file, or report an error about one that had since moved.
- When a file cannot be read with a new column number or delimiter, its data
and fit are cleared. They previously stayed on screen, and could be
exported, under settings that no longer described them.
- The data columns in use must each be different. Two quantities could
previously be read from the same column without any warning.
- The x tick label at the join between the Transmission and Deflection plots
is hidden when it collides with its neighbour. A rounding error let some
such labels through.
### Changed
- The source files carry the GPLv3 notice.
## [2.4] - 2026-09-21
First release recorded in this changelog. Earlier history is not documented
here.
### Fixed
- README parameter tables corrected to match the program's window: the
default T and DeltaEoE data columns were swapped, and several defaults,
labels and descriptions disagreed with what the interface shows.