11 KiB
BD Fresnel
Beam-deflection pump–probe simulator and fitting tool. A Python port of the
MATLAB BD_Fresnel_GUI suite.
The program models a weak probe beam crossing a sample that has been excited by
a strong pump, propagates the perturbed probe field to a detector by Fresnel
diffraction, and computes the transmission T and normalised beam deflection
ΔE/E as a function of pump–probe delay. Measured scans can be imported and
compared against the simulation, and the result exported as data, a log, and
publication-sized figures.
Two measurement modes are supported. Beam deflection fits both signals. Pump probe is for measurements with the probe centred on the pump, where there is no deflection: it fits the transmission alone, and needs only delay and transmission data.
Features
- Seven mechanism slots, each independently configurable, summed into the total nonlinear response.
- Instantaneous (electronic) and non-instantaneous responses, the latter convolved with the pulse envelope.
- Group-velocity mismatch between pump and probe handled through the walk-off
parameter
rho. - Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁, T₂) solved through the sample depth for a range of radial irradiances.
- Side-by-side transmission and deflection plots with imported data overlaid.
- Beam deflection and pump probe measurement modes. Pump probe reads a two-column delay/transmission scan, fixes the probe on the pump axis, and offers only the mechanisms that can change the transmission.
- Optional diagnostic figures showing each mechanism's response function before and after convolution, plus the ESA populations and beam transmissions.
- Export of the data/fit comparison, a full parameter log, and figures at 6.5 in / 300 dpi.
Requirements
- Python 3.10 or newer (developed against 3.12)
numpy,scipy,matplotlib,mpmath- Tkinter, which ships with most Python builds. On Debian/Ubuntu it is a separate package:
sudo apt install python3-tk
Install the Python dependencies with:
pip install -r requirements.txt
Running
python bd_fresnel_gui.py
The window opens with the parameter panel on the left and three tabs on the right: Fitting, Diagnostics, and Parameter log.
A typical session:
- Set the Data columns to match your file, and the delimiter.
- Choose the Mode: Beam deflection or Pump probe.
- Press Import… and choose a scan. The plots show the measured data.
- Fill in the beam, material and geometry parameters, and configure one or more mechanisms with the Params… buttons.
- Press Fit to run the simulation and overlay it on the data.
- Press Export… to write the results.
Fit stays disabled until a file is imported, and Export until a fit has completed.
Changing the mode, a column number or the delimiter re-reads the imported file. Any fit is discarded, since it belonged to the previous settings. If the file cannot be read with the new settings, its data is cleared rather than left on screen, and it is read again once the settings allow.
Parameters are saved to last_settings.json beside the scripts when they
change, and restored at the next launch. The data file itself is not restored.
Input data format
A delimited text file with one header line, then one row per delay point. Beam deflection needs three columns and pump probe two; which ones is set in the Data columns box, so extra columns can be present and ignored. Each quantity must come from a different column.
| Quantity | Units | Default column | Needed in |
|---|---|---|---|
τ_d |
fs | 1 | both modes |
ΔE/E |
fractional | 2 | Beam deflection only |
T |
fractional (1.0 = no change) | 3 | both modes |
The delimiter field takes a single character, \t for a tab, or is left blank
to split on any run of whitespace.
Parameters
Data columns (1-indexed)
| Variable | Default | Column contents |
|---|---|---|
tau_d column |
1 |
Delay column (fs) |
T column |
3 |
Transmission data column |
DeltaEoE column |
2 |
Deflection data column |
Delimiter |
, |
Data column delimiter character |
Mode
| Option | Effect |
|---|---|
Beam deflection |
Transmission and deflection, offset probe |
Pump probe |
Transmission only, centered probe |
Simulation parameters
| Variable | Default | Column contents |
|---|---|---|
X_num |
50 |
Number of spatial points |
X_max |
5.0 |
Range of spatial sampling (w_0) |
T_num |
100 |
Number of temporal points |
T_max |
5.0 |
Range of temporal sampling (tau_p) |
T_d_num |
150 |
Number of delay points over range |
Excitation beam parameters
| Variable | Default | Column contents |
|---|---|---|
E_p |
1.36 |
Excitation pulse energy (uJ) |
tau_p_FWHM |
55.0 |
Excitation pulse duration (fs) |
w_0p |
246.0 |
Excitation beam waist (um) |
lambda_p |
800.0 |
Excitation pulse wavelength (nm) |
Probe beam parameters
| Variable | Default | Column contents |
|---|---|---|
tau_FWHM |
60.0 |
Probe pulse duration (fs) |
w_0 |
43.0 |
Probe beam waist (um) |
lambda |
650.0 |
Probe pulse wavelength (nm) |
Material parameters at excitation wavelength
| Variable | Default | Column contents |
|---|---|---|
R_p |
0.0 |
Reflectivity |
alpha_p |
0.0 |
Linear absorption (cm^-1) |
n_p |
1.4533 |
Linear index |
dndl_p |
-0.017284 |
First order dispersion (um^-1) |
alpha_2d |
0.0 |
2 photon absorption (e-11 m/W) |
Material parameters at probe wavelength
| Variable | Default | Column contents |
|---|---|---|
R |
0.0 |
Reflectivity |
alpha |
0.0 |
Linear absorption (cm^-1) |
n |
1.4565 |
Linear index |
dndl |
-0.027158 |
First order dispersion (um^-1) |
Measurement parameters
| Variable | Default | Column contents |
|---|---|---|
l |
1.0 |
Sample thickness (mm) |
d |
15.0 |
Distance to detector (cm) |
shift |
0.0 |
Temporal shift (fs) |
x_0 |
0.5 |
Displacement of probe (w_0p) |
Mechanisms
| Mechanism | Parameters |
|---|---|
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
NLR denotes a purely refractive response, NLA a purely absorptive one, and
both a mechanism carrying each.
Pump probe offers only the NLA and both mechanisms: with the probe centred,
a both mechanism contributes its absorptive part, and an NLR mechanism
cannot change the transmission at all. Switching to Pump probe sets aside any
NLR mechanism already chosen; switching back restores it, provided its slot
is still empty.
Export output
Exporting to <name>_fit.txt also writes, in the same directory:
| File | Contents |
|---|---|
<name>_fit.txt |
delay, data and fit for T, ΔE/E and Δn; in Pump probe, delay and T only |
<name>_fit_log.txt |
every parameter, plus a manifest of the files written |
<name>_fit_combined.jpg / .svg |
transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
<name>_fit_transmission.jpg / .svg |
transmission only, 3.25 in at 300 dpi (Pump probe) |
<name>_fit_raw_response.jpg |
each mechanism's R[t] and A[t] |
<name>_fit_convolved_response.jpg |
the same after convolution, plus the total |
The last two appear only when Show diagnostic plots during Fit is ticked.
The log records enough to reproduce a run: data columns and delimiter, the
mode, the simulation grid, every beam, material and geometry value, each
mechanism with its parameters, and the derived quantities (n_g, T_lin,
z_0, I_0, rho).
Files
| File | Role |
|---|---|
bd_fresnel_core.py |
physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
bd_fresnel_gui.py |
Tkinter interface, plotting, import/export, logging. Entry point. |
set_params_dialog.py |
modal dialog for entering one mechanism's parameters. |
References
Please cite the following when using results from this program.
- Reichert, M., et al. (2014). "Temporal, spectral, and polarization dependence of the nonlinear optical response of carbon disulfide." Optica 1(6): 436.
- Reichert, M., et al. (2014). "Temporal, spectral, and polarization dependence of the nonlinear optical response of carbon disulfide: supplementary material." Optica 1(6): 436.
- Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and polarization resolved ultrafast nonlinear refraction." Opt. Lett. 38(18): 3518–3521.
License
Copyright (C) 2019-2026 Manuel R. Ferdinandus
This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with this program. If not, see https://www.gnu.org/licenses/.
NumPy, SciPy, Matplotlib and mpmath are all BSD-licensed, so distributing this program under the GPL alongside them poses no conflict.
