@@ -141,7 +141,7 @@ The program is split so the physics can be used without the interface:
|
||||
|
||||
## Parameters
|
||||
|
||||
## Data columns (1-indexed)
|
||||
### Data columns (1-indexed)
|
||||
|
||||
| Variable | Default | Column contents |
|
||||
|------------|---------|---------------------------------------|
|
||||
@@ -152,7 +152,7 @@ The program is split so the physics can be used without the interface:
|
||||
| `REF_col` | `7` | Reference detector signal (V) |
|
||||
| `FREQ_col` | `9` | Lock-in frequency column (V) |
|
||||
|
||||
## Processing flags
|
||||
### Processing flags
|
||||
|
||||
| Parameter | Meaning |
|
||||
|--------------------------------------|-------------------------------------------------------------|
|
||||
@@ -164,7 +164,7 @@ The program is split so the physics can be used without the interface:
|
||||
| `flip_OA_disp`, `flip_CA_disp` | Invert the normalized traces about 1 for display/fitting |
|
||||
| `show_CA` | Plot CA in the right panel; if `False`, plot CA/OA instead |
|
||||
|
||||
## Nonlinear coefficients
|
||||
### Nonlinear coefficients
|
||||
|
||||
| Parameter | Meaning | Units | Log units |
|
||||
|-----------|----------------------------------------|----------|------------|
|
||||
@@ -175,13 +175,13 @@ The program is split so the physics can be used without the interface:
|
||||
| `alpha_3` | Three-photon absorption coefficient | m³/W² | cm³/GW² |
|
||||
| `alpha_4` | Four-photon absorption coefficient | m⁵/W³ | cm⁵/GW³ |
|
||||
|
||||
## z-position offsets
|
||||
### z-position offsets
|
||||
|
||||
`Delta_z_OA`, `Delta_z_CA`, `Delta_z_OACA` (mm) shift the OA, CA, and CA/OA
|
||||
z-axes independently so that measured and simulated curves line up when the two
|
||||
detector arms are not perfectly co-registered.
|
||||
|
||||
## Sample parameters
|
||||
### Sample parameters
|
||||
|
||||
| Parameter | Meaning | Units |
|
||||
|-------------|---------------------------------------------|-------|
|
||||
@@ -189,7 +189,7 @@ detector arms are not perfectly co-registered.
|
||||
| `L` | Sample thickness | m |
|
||||
| `T_lin` | Linear transmittance | — |
|
||||
|
||||
## Laser parameters
|
||||
### Laser parameters
|
||||
|
||||
| Parameter | Meaning | Units |
|
||||
|-------------|---------------------------------------------|-------|
|
||||
@@ -199,14 +199,14 @@ detector arms are not perfectly co-registered.
|
||||
| `tau_FWHM` | Pulse duration, FWHM of irradiance | s |
|
||||
| `M2` | Beam quality parameter M² | — |
|
||||
|
||||
## Measurement parameters
|
||||
### Measurement parameters
|
||||
|
||||
| Parameter | Meaning | Units |
|
||||
|-------------|---------------------------------------------|-------|
|
||||
| `S` | Linear transmission of the aperture | — |
|
||||
| `d` | Distance from focus to aperture | m |
|
||||
|
||||
## Error estimates
|
||||
### Error estimates
|
||||
|
||||
`E_err`, `w_err`, and `tau_err` are fractional uncertainties on the energy,
|
||||
waist, and pulse duration; they are combined in quadrature into `Tot_err` and
|
||||
@@ -214,7 +214,7 @@ written to the log as the systematic uncertainty on the extracted coefficients.
|
||||
— `E_err`, `w_err`, `tau_err`, as fractions, propagated into the reported
|
||||
uncertainty
|
||||
|
||||
## Simulation parameters
|
||||
### Simulation parameters
|
||||
|
||||
| Parameter | Default | Meaning |
|
||||
|-------------|---------|-----------------------------------------------------|
|
||||
|
||||
Reference in New Issue
Block a user