# Changelog
|
||||||
|
|
||||||
|
All notable changes to Z-Scan Beam Simulation are documented in this file.
|
||||||
|
|
||||||
|
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
||||||
|
|
||||||
|
## [Unreleased]
|
||||||
|
|
||||||
|
## [1.5] - 2026-09-23
|
||||||
|
|
||||||
|
### Added
|
||||||
|
|
||||||
|
- **Operation Mode** box, above Data File: a two-button toggle selecting
|
||||||
|
**Fitting** or **Simulation**. Fitting is the default and behaves as
|
||||||
|
before.
|
||||||
|
- Simulation mode, which calculates and displays the signals with no
|
||||||
|
measured data:
|
||||||
|
- The Data File, Data Columns and Processing Flags inputs are
|
||||||
|
disabled, as are Import and Refine Fit, and the Referenced /
|
||||||
|
Normalized tab. **Max iterations** is disabled too, since it caps
|
||||||
|
Refine Fit. **Show CA (else OA/CA)** stays available, since it
|
||||||
|
selects which curve the right-hand plot shows and both are
|
||||||
|
simulated.
|
||||||
|
- Run Simulation is available without importing anything.
|
||||||
|
- The z range is set by a new **z range (sim.)** field, in Rayleigh
|
||||||
|
ranges either side of focus (default 15). It is disabled in Fitting
|
||||||
|
mode, where the range still comes from the data.
|
||||||
|
- The Fit Results plots show the simulated curves alone, with 5% of
|
||||||
|
the vertical span left clear above and below them, and the log
|
||||||
|
reports the simulated peak-to-valley values in place of the
|
||||||
|
data-versus-fit comparison and chi-squares.
|
||||||
|
- Export asks where to write the files, since there is no imported
|
||||||
|
file to name them from, and writes the simulated curves, the log and
|
||||||
|
the plot images.
|
||||||
|
- The selected mode and the simulation z range are saved with the other
|
||||||
|
settings.
|
||||||
|
|
||||||
|
### Changed
|
||||||
|
|
||||||
|
- **Show CA (else OA/CA)** now repeats the run, in either mode, so the
|
||||||
|
right-hand plot follows the tick immediately instead of waiting for
|
||||||
|
the next manual run. Nothing happens if no run has been made yet.
|
||||||
|
- Changing the operation mode clears the results on screen, which were
|
||||||
|
produced under the other mode. An imported scan is kept, so returning
|
||||||
|
to Fitting does not require importing again.
|
||||||
|
|
||||||
|