Author SHA1 Message Date
manuel 1bc882e163 Upload files to "docs" 2026-11-16 17:43:00 +00:00
manuel 50d0d27464 Upload files to "/" 2026-11-16 17:40:42 +00:00
manuel 45efc8239d Upload files to "/" 2026-11-16 17:40:21 +00:00
manuel d7ab1b823e Merge pull request 'Simulation mode' (#4) from simulation_mode into main
Reviewed-on: #4
2026-09-30 15:21:49 +00:00
manuel 98e95180cc Upload files to "/" 2026-09-30 15:20:45 +00:00
manuel 38c09a4272 Upload files to "/" 2026-09-30 15:20:31 +00:00
manuel cc67401de9 Upload files to "docs" 2026-09-30 15:19:54 +00:00
manuel 6d7996ff30 Upload files to "docs" 2026-09-30 15:17:57 +00:00
manuel 61dbd0452b Merge pull request 'Pump probe mode' (#3) from pump_probe_mode into main
Reviewed-on: #3
2026-09-23 01:20:45 +00:00
7 changed files with 1732 additions and 446 deletions
+287 -5
View File
@@ -4,7 +4,292 @@ All notable changes to BD Fresnel are documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/). The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
## [Unreleased] ## [3.0] - 2026-11-14
### Added
- **Semi-analytical** algorithm, selectable from a third toggle in the
Operation mode box alongside **Fresnel propagation**:
- Instead of propagating the exit field to the detector by FFT, it
uses closed-form expressions for the power difference and total at
the detector, already integrated over the detector plane. Only an
integral over time at each delay remains.
- The time window runs +/- 5T about each delay, where T = tau_p/tau_e.
- Transmission is the energy total normalised to its value before the
pump arrives: the first delay point when fitting, and
min(-3 rho, -3) tau_e when simulating, so a thin sample with
rho -> 0 still normalises away from the peak.
- `X_num` and `X_max` are disabled in this mode: the expressions are
already integrated over space, so there is no spatial grid.
- Applies to both measurement modes. In pump probe the probe is
centred, x_0 = 0, so the deflection term vanishes identically and
the transmission alone is calculated.
- Both algorithms are kept so results can be compared. Switching
discards the current result, which belongs to the other method.
- The algorithm is saved with the other settings and recorded in the
parameter log.
- The absorptive term in the deflection expression carries a
PROVISIONAL coefficient, `SA_ABSORPTIVE_FACTOR`. As derived, that
term matched neither the sign nor the magnitude of the Fresnel
result: a purely absorptive mechanism disagreed by a factor of
about -69, with correlation exactly -1. Dividing by
D = d / (pi w_0_p^2 / lambda_p) = d / z_0_p accounts for the distance and
wavelength dependence exactly, and is independent of sample
thickness at constant alpha_2_exp*l; the remaining -1/(1 + 2W^2) was
measured against the Fresnel path rather than derived. With it the
two methods agree to 0.5% for mechanisms with a refractive part and
4.5% for purely absorptive ones. It is isolated in one function
pending a corrected derivation.
- The parameter log's `Calculated Parameters (pump)` section reports
`sigma_e`, the normalised pump linear absorption `alpha_e * L / 2`.
It sits next to `T_lin`, which restates it: with no pump two-photon
absorption `T_lin = (1 - R_p) exp(-2 sigma_e)`. Read from the
parameters rather than the result, so it is reported for either
algorithm.
- The `Other` panel and the parameter log's `Other` section both report
`eta (peak)` and `Gamma (peak)`, the largest nonlinear phase and
absorption exponent anywhere on the grid, from whichever algorithm
produced the result. These are the only readouts in those panels that
come from the result rather than from the parameters, since they are
peaks over the whole (T, T_d) grid and cannot be had without running
the calculation. They therefore show `--` until a Fit or Simulate
completes, and return to `--` whenever that result is discarded, so a
stale phase is never displayed beside freshly edited parameters.
`eta (peak)` is the yardstick for the semi-analytical algorithm's
validity: its `dP` is first order in the response while Fresnel
propagation keeps every order, so the two agree only while the phase
is small. On the 4-layer mechanisms the peak of `DeltaEoE` sits at
the same delay to within 0.0003 tau_e at `eta (peak)` = 0.14, but
0.0035 at 1.41, 0.077 at 5.6 and 0.36 at 14.1. Holding `eta (peak)`
fixed, the agreement is unaffected by sample thickness (0.05 to
2 mm), by walk-off (`rho` 0.04 to 1.7) and by pump absorption
(`sigma_e` 0 to 10), so this one number sets the regime. Both
algorithms report it to within 2e-5 of each other.
### Changed
- **Both beams are now explicitly subscripted: the pump carries `_e`
(excitation) and the probe carries `_p`.** This restores the
convention the original MATLAB used, which the Python port had
partly inverted (`_p` for the pump) and partly dropped (no suffix
for the probe). No beam quantity is unsubscripted any more; the only
unsuffixed parameters left are the ones belonging to neither beam --
the sampling grid, the sample geometry (`l`, `d`, `shift`), the
relative offset `x_0`, and the walk-off `rho`.
| pump: was | now | | probe: was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_FWHM` | `tau_p_FWHM` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `w_0` | `w_0_p` |
| `w_0p` | `w_0_e` | | `lambda_` | `lambda_p` |
| `lambda_p` | `lambda_e` | | `R` | `R_p` |
| `R_p` | `R_e` | | `alpha` | `alpha_p` |
| `alpha_p` | `alpha_e` | | `n` | `n_p` |
| `n_p` | `n_e` | | `dndl` | `dndl_p` |
| `dndl_p` | `dndl_e` | | `tau` | `tau_p` |
| `alpha_2d` | `alpha_2d_e` | | `ng` | `ng_p` |
| `tau_p` | `tau_e` | | `z_0` | `z_0_p` |
| `sigma_p` | `sigma_e` | | `Tlin` | `Tlin_p` |
| `I_0_p` | `I_0_e` | | | |
| `ng_p` | `ng_e` | | | |
| `z_0_p` | `z_0_e` | | | |
| `Tlin_p` | `Tlin_e` | | | |
| `sigma_p2` / `sigma_p20` | `sigma_e2` / `sigma_e20` | | | |
| `a_p_0`, `W_0_p`, `I_p_pulse` | `a_e_0`, `W_0_e`, `I_e_pulse` | | | |
Note that six probe names -- `tau_p_FWHM`, `lambda_p`, `R_p`,
`alpha_p`, `n_p`, `dndl_p` -- are spelled exactly like what were
**pump** names before this release. Reading an old log or settings
file alongside a new one needs care; see the settings note below for
how the program itself is protected.
The pump pass renamed 389 identifier occurrences textually; the
probe pass was done by rewriting 116 exact AST node positions
instead, because `n`, `R`, `alpha` and `tau` are overloaded in this
codebase (lambda parameters, the author's initials in the copyright
line, the semi-analytical formula's geometric `R`, a diagnostics
dict key) and no text pattern distinguishes them.
| was | now | | was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_p` | `tau_e` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `sigma_p` | `sigma_e` |
| `w_0p` | `w_0_e` | | `I_0_p` | `I_0_e` |
| `lambda_p` | `lambda_e` | | `ng_p` | `ng_e` |
| `R_p` | `R_e` | | `z_0_p` | `z_0_e` |
| `alpha_p` | `alpha_e` | | `Tlin_p` | `Tlin_e` |
| `n_p` | `n_e` | | `sigma_p2` | `sigma_e2` |
| `dndl_p` | `dndl_e` | | `sigma_p20` | `sigma_e20` |
| `alpha_2d` | `alpha_2d_e` | | `a_p_0` | `a_e_0` |
`w_0p` gains the separating underscore it was missing, so the field
name finally matches the variable that held it (`w_0_p`) and its
siblings `z_0_e` and `I_0_e`. `alpha_2d_e` keeps the `d` for
degenerate.
- **The Electronic mechanism's parameters are renamed `alpha_2e` ->
`alpha_2el` and `n_2e` -> `n_2el`**, since their `e` meant
*electronic* and would otherwise collide with `_e` for excitation --
the pump's degenerate two-photon coefficient would have wanted the
name `alpha_2e`, which was taken. `_e` now means excitation and
nothing else.
- `BD_3_level_triplet`, `I_e_func` and `excite_prop` needed no
renaming at all: transliterated from the MATLAB, they already used
`_e` for the pump and `_p` for the probe, so `n_g_p`, `v_p` and
`I_p` inside them were correct all along. With both beams now
subscribed to that convention, the whole file reads against the
MATLAB without translation.
- **`last_settings.json` written by an earlier version is now refused
rather than misread.** Saved settings carry a `settings_schema`
stamp, and a file without the current one is rejected with a message
explaining why. This is not housekeeping: because six probe field
names are spelled exactly like former pump keys, loading an old file
by name alone would have installed the pump's wavelength, index,
reflectivity, absorption and dispersion as the *probe's* -- every
number plausible, every result wrong. Re-enter the parameters once
and they save in the new layout. Any other unrecognised key is still
dropped with a note on stderr.
- Log and panel labels follow their fields on both sides: `n_g_e`,
`sigma_e`, `T_lin_e`, `z_0_e`, `I_0_e` for the pump and `n_g_p`,
`T_lin_p`, `z_0_p` for the probe, with the beam parameters and
material blocks likewise. The GUI's pump calculated-parameters panel
also gains a `sigma_e` readout, which it had not displayed before.
- `T_lin_p` and `T_lin_e` are labelled `T_lin_p (transmission)` and
`T_lin_e (transmission)` in both the panel and the log, so the
quantity is named and not just abbreviated. The log's value column
moved from 25 to 29 to fit them, and the panel's label column from 20
to 23 characters -- which also squares up `z_0_p (Rayleigh range)`,
`z_0_e (Rayleigh range)` and `I_0_e (peak irradiance)`, all of which
had been overrunning the old 20 and pushing their own values out of
line.
- The rename is numerically inert: across 8 mechanism types x 2
algorithms x 3 pump-absorption configurations (49 cases, 3275
values), `DeltaEoE`, `T`, `Delta_n`, `eta_peak` and `Gamma_peak` are
bit-identical to the pre-rename code, and `pyflakes` reports zero
warnings before and after.
- Transmission y-axis tick labels are limited to three significant
digits, so "99.75" reads "99.8". The count is a floor rather than a
cap: a shallow scan spanning a few hundredths of a percent would
round every tick to "100", so digits are added only where that would
happen. The deflection axis is unaffected.
- The reference list in the README and the parameter log follows Optica
style: every author listed, initials first, abbreviated journal,
volume, full page range, year. Author lists and page ranges were
checked against the published papers.
- The duplicate supplementary-material citation is dropped, leaving two
references.
- The parameter log is written as UTF-8. The citations use typographic
quotes and an en dash, which the locale's encoding cannot always
represent.
### Fixed
- The instantaneous (Electronic) response for a sample with both
walk-off and pump absorption is evaluated through the scaled
complementary error function `erfcx` instead of the form in
`BD_Fresnel_func_ni.m`. That form multiplied `exp(sigma_e^2/rho^2 +
2 sigma_e u/rho)` by a difference of error functions falling to zero,
so the product was lost to cancellation well before it overflowed:
at `rho = 0.4336` (l = 0.5 mm) it was already wrong over 8.6% of the
delay axis at `sigma_e = 2.5` (alpha_e = 100 cm^-1), **returning
exactly 0.0 with no NaN to signal it**, and returned NaN above
`sigma_e = 3`. The usable ceiling on `alpha_e` for an Electronic
mechanism at that thickness was therefore about 60 cm^-1, not the
~120 where NaN first appeared. The rearrangement is algebraic, with
every surviving exponent non-positive; it reproduces the original
evaluated at 600 decimal digits to 1e-16..3e-13 relative over
`sigma_e` = 0.25 to 10 and `u` = -3 to 18, both where the original
works and where it does not.
- Pump absorption is applied to non-instantaneous mechanisms when the
walk-off is exactly zero. Substituting `T1 = (T+T_d) - rho +
rho*zeta` shows the `rho != 0` branch to be a depth average over
`atten_fac`, whose `rho -> 0` limit is the response at one instant
times the *mean* of `atten_fac`; the original used the bare response.
The dropped factor is `(1 - exp(-2 sigma_e))/(2 sigma_e)` for linear
pump absorption, so the response was previously **independent of
`alpha_e` altogether** in this case -- identical at `alpha_e` = 0 and
200 cm^-1. It was 1.27x too large at `alpha_e` = 10 cm^-1 and
l = 0.5 mm, and 10x at 200 cm^-1. The two branches now agree to nine
digits across `rho = 0`. This affects only samples with `ng_p` exactly
equal to `ng_e` (for example no dispersion entered at either
wavelength) *and* non-zero pump absorption; with `alpha_e = alpha_2d_e
= 0` the mean is exactly 1 and results are bit-identical to before.
- Pump absorption through the sample depth, `atten_fac`, is computed
from the closed-form solution of
`dI_e/dz = -alpha_e I_e - alpha_2d_e I_e^2` rather than the two-branch
expression carried over from `BD_Fresnel_func_ni.m`. That expression's
pump two-photon branch, `sqrt((B1 B2)/sigma_e)`, failed three ways: it
did not reduce to its own `sigma_e2 == 0` branch as `alpha_2d_e -> 0`
(it decayed at half the correct rate), it divided by zero whenever
`alpha_e` was zero, and it took the square root of a negative number
whenever `sigma_e20 > sigma_e`. The net effect was that **every run
combining a non-zero `alpha_2d_e` with a non-instantaneous mechanism
returned NaN at every delay** -- pump two-photon absorption worked
only for the Electronic mechanism, which does not use `atten_fac`.
Dropping the stray square root recovers that expression as the
linearisation of the exact one in `sigma_e20`, which is how the
intent was identified. Results for `alpha_2d_e = 0` are bit-identical
to before; the new form agrees with numerical integration of the
pump propagation equation to 2e-12 relative over `sigma_e` and
`sigma_e20` from 0 to 20, including both limits.
- A negative `alpha_2d_e` large enough to make the pump diverge inside
the sample (two-photon gain, no finite depth average) is now refused
with a message naming the largest `|alpha_2d_e|` that works for the
current thickness and pump irradiance, rather than silently returning
a meaningless attenuation of order 1e12.
- `mpmath` is imported only where it is used, in the pump two-photon
absorption term. Importing it at module level made an optional
dependency fatal at startup, so the program would not run at all
without it. If that term is ever reached without mpmath installed,
the error now says which package is missing and why.
## [2.6] - 2026-09-30
### Added
- **Simulation** run mode: a second toggle in the Operation mode box,
offering **Fitting** and **Simulation**. Fitting is the default and
behaves as before.
- Simulation mode, for computing a signal without a measurement:
- No file is imported. **Import...** and the data column and
delimiter fields are disabled.
- The delay range is entered as `T_d_min` and `T_d_max` (in `tau_p`)
in the Simulation parameters box. In Fitting mode these are taken
from the imported scan and the fields are disabled.
- Only the calculated curves are plotted, without data markers, and
the plot legend reads **Simulated** rather than Fit.
- The **Fit** button is relabelled **Simulate**, and is enabled by
valid parameters alone rather than by an imported file.
- The export holds the calculated signals on their own delay grid,
with no data columns to pair them with. The parameter log omits the
import path and the data column section.
- The mode combines with the measurement mode: Pump probe and
Simulation together give a single Transmission panel and a
two-column table, as Pump probe does when fitting.
- The run mode is saved with the other settings and recorded in the
parameter log.
### Changed
- The **Mode** box is renamed **Operation mode** and moved to the top of
the parameter panel, above Data columns. The parameter log and status
messages use the new name, and the log records both modes on one line.
- Changing run mode discards the current result, which described the
other mode's delay range or a measurement the new mode does not show.
Switching to Simulation sets the imported scan aside and switching
back reloads it. The run mode cannot be changed while a fit runs.
- `inputs_valid` takes a `require_data` argument, so Simulation can
enable its action button without an imported file. Fitting is
unaffected.
## [2.5] - 2026-09-21 ## [2.5] - 2026-09-21
@@ -38,6 +323,7 @@ The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
mode's column requirements. A file the new mode cannot use is cleared mode's column requirements. A file the new mode cannot use is cleared
with an explanation, and loaded again on switching back. The mode with an explanation, and loaded again on switching back. The mode
cannot be changed while a fit runs. cannot be changed while a fit runs.
- The source files carry the GPLv3 notice.
### Fixed ### Fixed
@@ -61,10 +347,6 @@ The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
is hidden when it collides with its neighbour. A rounding error let some is hidden when it collides with its neighbour. A rounding error let some
such labels through. such labels through.
### Changed
- The source files carry the GPLv3 notice.
## [2.4] - 2026-09-21 ## [2.4] - 2026-09-21
First release recorded in this changelog. Earlier history is not documented First release recorded in this changelog. Earlier history is not documented
+142 -56
View File
@@ -15,6 +15,10 @@ Two measurement modes are supported. **Beam deflection** fits both signals.
there is no deflection: it fits the transmission alone, and needs only delay there is no deflection: it fits the transmission alone, and needs only delay
and transmission data. and transmission data.
The program also runs without a measurement. In **Simulation** mode nothing is
imported: the signal is computed from the parameters alone, over a delay range
entered by hand, and only the calculated curves are plotted and exported.
![BD Fresnel fitting a measured scan](docs/screenshot.png) ![BD Fresnel fitting a measured scan](docs/screenshot.png)
## Features ## Features
@@ -27,10 +31,17 @@ and transmission data.
parameter `rho`. parameter `rho`.
- Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁, - Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁,
T₂) solved through the sample depth for a range of radial irradiances. T₂) solved through the sample depth for a range of radial irradiances.
- Side-by-side transmission and deflection plots with imported data overlaid. - Side-by-side transmission and deflection plots, with imported data overlaid
when there is any.
- Beam deflection and pump probe measurement modes. Pump probe reads a - Beam deflection and pump probe measurement modes. Pump probe reads a
two-column delay/transmission scan, fixes the probe on the pump axis, and two-column delay/transmission scan, fixes the probe on the pump axis, and
offers only the mechanisms that can change the transmission. offers only the mechanisms that can change the transmission.
- Fitting and simulation run modes. Simulation computes the signal with no
data imported, over a delay range entered in the panel.
- Two interchangeable algorithms. Fresnel propagation carries the exit field to
the detector by FFT; the semi-analytical method uses closed-form detector
power expressions instead, needing no spatial grid and running about 32x
faster, at the cost of holding only to first order in the nonlinear response.
- Optional diagnostic figures showing each mechanism's response function before - Optional diagnostic figures showing each mechanism's response function before
and after convolution, plus the ESA populations and beam transmissions. and after convolution, plus the ESA populations and beam transmissions.
- Export of the data/fit comparison, a full parameter log, and figures at - Export of the data/fit comparison, a full parameter log, and figures at
@@ -62,18 +73,31 @@ python bd_fresnel_gui.py
The window opens with the parameter panel on the left and three tabs on the The window opens with the parameter panel on the left and three tabs on the
right: **Fitting**, **Diagnostics**, and **Parameter log**. right: **Fitting**, **Diagnostics**, and **Parameter log**.
A typical session: Fitting a measured scan:
1. Set the **Data columns** to match your file, and the delimiter. 1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**,
2. Choose the **Mode**: Beam deflection or Pump probe. leave the second toggle on **Fitting**, and pick an algorithm on the third:
**Fresnel propagation** or the faster **Semi-analytical**.
2. Set the **Data columns** to match your file, and the delimiter.
3. Press **Import…** and choose a scan. The plots show the measured data. 3. Press **Import…** and choose a scan. The plots show the measured data.
4. Fill in the beam, material and geometry parameters, and configure one or 4. Fill in the beam, material and geometry parameters, and configure one or
more mechanisms with the **Params…** buttons. more mechanisms with the **Params…** buttons.
5. Press **Fit** to run the simulation and overlay it on the data. 5. Press **Fit** to run the simulation and overlay it on the data.
6. Press **Export…** to write the results. 6. Press **Export…** to write the results.
**Fit** stays disabled until a file is imported, and **Export** until a fit has Simulating without a measurement:
completed.
1. Under **Operation mode**, choose **Simulation**. **Import…** and the data
column fields are disabled, and **Fit** becomes **Simulate**. The algorithm
toggle works the same way as in Fitting mode.
2. Set `T_d_min` and `T_d_max` in **Simulation parameters** to the delay range
to compute over. In Fitting mode these come from the imported file, so they
are editable only here.
3. Fill in the parameters and mechanisms as above.
4. Press **Simulate**, then **Export…**.
**Fit** stays disabled until a file is imported; **Simulate** needs only valid
parameters. **Export** stays disabled until a fit or simulation has completed.
Changing the mode, a column number or the delimiter re-reads the imported file. Changing the mode, a column number or the delimiter re-reads the imported file.
Any fit is discarded, since it belonged to the previous settings. If the file Any fit is discarded, since it belonged to the previous settings. If the file
@@ -91,7 +115,7 @@ deflection needs three columns and pump probe two; which ones is set in the
quantity must come from a different column. quantity must come from a different column.
| Quantity | Units | Default column | Needed in | | Quantity | Units | Default column | Needed in |
| --- | --- | --- | --- | |----------|------------------------------|----------------|----------------------|
| `τ_d` | fs | 1 | both modes | | `τ_d` | fs | 1 | both modes |
| `ΔE/E` | fractional | 2 | Beam deflection only | | `ΔE/E` | fractional | 2 | Beam deflection only |
| `T` | fractional (1.0 = no change) | 3 | both modes | | `T` | fractional (1.0 = no change) | 3 | both modes |
@@ -104,78 +128,137 @@ to split on any run of whitespace.
### Data columns (1-indexed) ### Data columns (1-indexed)
| Variable | Default | Column contents | | Variable | Default | Column contents |
|-------------------|---------|---------------------------------------| |-------------------|---------|---------------------------------|
| `tau_d column` | `1` | Delay column (fs) | | `tau_d column` | `1` | Delay column (fs) |
| `T column` | `3` | Transmission data column | | `T column` | `3` | Transmission data column |
| `DeltaEoE column` | `2` | Deflection data column | | `DeltaEoE column` | `2` | Deflection data column |
| `Delimiter` | `,` | Data column delimiter character | | `Delimiter` | `,` | Data column delimiter character |
### Mode ### Operation mode
| Option | Effect | Three independent toggles. Any combination is valid.
|-------------------|-------------------------------------------------|
| `Beam deflection` | Transmission and deflection, offset probe | | Toggle | Option | Effect |
| `Pump probe` | Transmission only, centered probe | |-------------|-----------------------|--------------------------------------------------|
| Measurement | `Beam deflection` | Transmission and deflection, offset probe |
| | `Pump probe` | Transmission only, centered probe |
| Run | `Fitting` | Compare the calculation against an imported scan |
| | `Simulation` | Calculate without a scan, over an entered range |
| Algorithm | `Fresnel propagation` | Propagate the exit field to the detector by FFT |
| | `Semi-analytical` | Closed-form detector power, no spatial grid |
#### Algorithm
**Fresnel propagation** is the original method. The field at the exit face is
built on an (x, y) grid, propagated to the detector by FFT, and integrated over
the detector halves to get the power difference and total at each instant.
**Semi-analytical** skips the propagation. It evaluates closed-form expressions
for the detector power difference `dP` and total `P`, already integrated over
the detector plane, then integrates each over time at every delay to get the
energy difference `dE` and total `E`. The deflection is `dE/E` and the
transmission is `E` normalised. With no spatial grid to size, `X_num` and
`X_max` are greyed out; every other parameter, `Delta_n` included, is
unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about
**32x faster**.
The trade-off is that `dP` is **first order in the nonlinear response**, where
the Fresnel path keeps every order. The two therefore agree only while the
phase is small, which the `eta (peak)` line of the parameter log reports:
| `eta (peak)` | Peak of `DeltaEoE` displaced by |
|--------------|---------------------------------|
| 0.14 rad | 0.0003 tau_e |
| 1.41 rad | 0.0035 tau_e |
| 5.64 rad | 0.077 tau_e |
| 14.1 rad | 0.36 tau_e |
Below roughly 1 rad the two are interchangeable, and the four-layer example sits
at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a
few rad the semi-analytical curve shifts noticeably and is no longer a
substitute. Sample thickness, walk-off and pump absorption do not themselves
affect the agreement once `eta (peak)` is held fixed.
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`
is the pump amplitude profile, while the semi-analytical form uses the on-axis
`exp(-2 x_0^2)`.
One coefficient in `dP`'s absorptive term, `SA_ABSORPTIVE_FACTOR`, is at present
fitted against the Fresnel path rather than derived. It is isolated in a single
function in `bd_fresnel_core.py`, with the measurements behind it recorded
there.
The transmission needs a reference delay, taken from before the pump arrives.
In **Fitting** mode it is the first delay point of the imported scan; in
**Simulation** mode it is `min(-3 rho, -3)` tau_e, which follows the walk-off
when that is the larger scale and is three pulse widths otherwise, so a thin
sample still normalises away from the peak.
### Simulation parameters ### Simulation parameters
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|---------|---------------------------------------| |-----------|---------|-------------------------------------------------|
| `X_num` | `50` | Number of spatial points | | `X_num` | `50` | Number of spatial points, Fresnel only |
| `X_max` | `5.0` | Range of spatial sampling (w_0) | | `X_max` | `5.0` | Range of spatial sampling (w_0_p), Fresnel only |
| `T_num` | `100` | Number of temporal points | | `T_num` | `100` | Number of temporal points |
| `T_max` | `5.0` | Range of temporal sampling (tau_p) | | `T_max` | `5.0` | Range of temporal sampling (tau_e) |
| `T_d_num` | `150` | Number of delay points over range | | `T_d_num` | `150` | Number of delay points over range |
| `T_d_min` | `-5.0` | Delay range start (tau_e), Simulation only |
| `T_d_max` | `5.0` | Delay range end (tau_e), Simulation only |
`X_num` and `X_max` size the spatial grid the Fresnel method propagates, so the
semi-analytical method greys them out.
### Excitation beam parameters ### Excitation beam parameters
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|---------|---------------------------------------| |--------------|---------|----------------------------------|
| `E_p` | `1.36` | Excitation pulse energy (uJ) | | `E_e` | `1.36` | Excitation pulse energy (uJ) |
| `tau_p_FWHM` | `55.0` | Excitation pulse duration (fs) | | `tau_e_FWHM` | `55.0` | Excitation pulse duration (fs) |
| `w_0p` | `246.0` | Excitation beam waist (um) | | `w_0_e` | `246.0` | Excitation beam waist (um) |
| `lambda_p` | `800.0` | Excitation pulse wavelength (nm) | | `lambda_e` | `800.0` | Excitation pulse wavelength (nm) |
### Probe beam parameters ### Probe beam parameters
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|---------|---------------------------------------| |--------------|---------|-----------------------------|
| `tau_FWHM` | `60.0` | Probe pulse duration (fs) | | `tau_p_FWHM` | `60.0` | Probe pulse duration (fs) |
| `w_0` | `43.0` | Probe beam waist (um) | | `w_0_p` | `43.0` | Probe beam waist (um) |
| `lambda` | `650.0` | Probe pulse wavelength (nm) | | `lambda_p` | `650.0` | Probe pulse wavelength (nm) |
### Material parameters at excitation wavelength ### Material parameters at excitation wavelength
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|-------------|-----------------------------------| |--------------|-------------|--------------------------------|
| `R_p` | `0.0` | Reflectivity | | `R_e` | `0.0` | Reflectivity |
| `alpha_p` | `0.0` | Linear absorption (cm^-1) | | `alpha_e` | `0.0` | Linear absorption (cm^-1) |
| `n_p` | `1.4533` | Linear index | | `n_e` | `1.4533` | Linear index |
| `dndl_p` | `-0.017284` | First order dispersion (um^-1) | | `dndl_e` | `-0.017284` | First order dispersion (um^-1) |
| `alpha_2d` | `0.0` | 2 photon absorption (e-11 m/W) | | `alpha_2d_e` | `0.0` | 2 photon absorption (e-11 m/W) |
### Material parameters at probe wavelength ### Material parameters at probe wavelength
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|-------------|-----------------------------------| |-----------|-------------|--------------------------------|
| `R` | `0.0` | Reflectivity | | `R_p` | `0.0` | Reflectivity |
| `alpha` | `0.0` | Linear absorption (cm^-1) | | `alpha_p` | `0.0` | Linear absorption (cm^-1) |
| `n` | `1.4565` | Linear index | | `n_p` | `1.4565` | Linear index |
| `dndl` | `-0.027158` | First order dispersion (um^-1) | | `dndl_p` | `-0.027158` | First order dispersion (um^-1) |
### Measurement parameters ### Measurement parameters
| Variable | Default | Column contents | | Variable | Default | Column contents |
|----------------|-------------|-----------------------------------| |----------|---------|-------------------------------|
| `l` | `1.0` | Sample thickness (mm) | | `l` | `1.0` | Sample thickness (mm) |
| `d` | `15.0` | Distance to detector (cm) | | `d` | `15.0` | Distance to detector (cm) |
| `shift` | `0.0` | Temporal shift (fs) | | `shift` | `0.0` | Temporal shift (fs) |
| `x_0` | `0.5` | Displacement of probe (w_0p) | | `x_0` | `0.5` | Displacement of probe (w_0_e) |
## Mechanisms ## Mechanisms
| Mechanism | Parameters | | Mechanism | Parameters |
| --- | --- | |--------------------------------|------------|
| Electronic (both) | 2 | | Electronic (both) | 2 |
| Collisional (NLR) | 3 | | Collisional (NLR) | 3 |
| Librational (NLR) | 4 | | Librational (NLR) | 4 |
@@ -200,8 +283,8 @@ is still empty.
Exporting to `<name>_fit.txt` also writes, in the same directory: Exporting to `<name>_fit.txt` also writes, in the same directory:
| File | Contents | | File | Contents |
| --- | --- | |----------------------------------------|------------------------------------------------------------------------------------------------------------------------------|
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only | | `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written | | `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) | | `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) | | `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
@@ -210,15 +293,20 @@ Exporting to `<name>_fit.txt` also writes, in the same directory:
The last two appear only when *Show diagnostic plots during Fit* is ticked. The last two appear only when *Show diagnostic plots during Fit* is ticked.
The log records enough to reproduce a run: data columns and delimiter, the In Simulation mode the export is named after the file you choose rather than an
mode, the simulation grid, every beam, material and geometry value, each imported scan, and the table holds the calculated signals on their own delay
mechanism with its parameters, and the derived quantities (`n_g`, `T_lin`, grid, with no data columns to pair them with.
`z_0`, `I_0`, `rho`).
The log records enough to reproduce a run: both modes, the data columns and
delimiter, the simulation grid including the delay range, every beam, material
and geometry value, each mechanism with its parameters, and the derived
quantities (`n_g`, `T_lin`, `z_0`, `I_0`, `rho`). In Simulation mode the import
path and data column sections are omitted, having nothing to describe.
## Files ## Files
| File | Role | | File | Role |
| --- | --- | |------------------------|--------------------------------------------------------------------------------------------------------------------------|
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. | | `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. | | `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. | | `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
@@ -227,15 +315,13 @@ mechanism with its parameters, and the derived quantities (`n_g`, `T_lin`,
Please cite the following when using results from this program. Please cite the following when using results from this program.
1. Reichert, M., et al. (2014). "Temporal, spectral, and polarization 1. M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, T. R. Ensley,
dependence of the nonlinear optical response of carbon disulfide." D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and
*Optica* **1**(6): 436. E. W. Van Stryland, “Temporal, spectral, and polarization dependence of the
2. Reichert, M., et al. (2014). "Temporal, spectral, and polarization nonlinear optical response of carbon disulfide,” Optica **1**, 436–445 (2014).
dependence of the nonlinear optical response of carbon disulfide: 2. M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and E. W. Van Stryland,
supplementary material." *Optica* **1**(6): 436. “Beam deflection measurement of time and polarization resolved ultrafast
3. Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and nonlinear refraction,” Opt. Lett. **38**, 3518–3521 (2013).
polarization resolved ultrafast nonlinear refraction." *Opt. Lett.*
**38**(18): 3518–3521.
## License ## License
+597 -166
View File
File diff suppressed because it is too large Load Diff
+471 -154
View File
@@ -61,11 +61,15 @@ from bd_fresnel_core import (
MECHANISM_NAMES, MECHANISM_NAMES,
calc_beam_params, calc_beam_params,
inputs_valid, inputs_valid,
BD_Fresnel_func_ni, BD_Fresnel_run,
save_settings, save_settings,
load_settings, load_settings,
MODE_BEAM_DEFLECTION, MODE_BEAM_DEFLECTION,
MODE_PUMP_PROBE, MODE_PUMP_PROBE,
RUN_MODE_FITTING,
RUN_MODE_SIMULATION,
ALGO_FRESNEL,
ALGO_SEMI_ANALYTICAL,
mechanism_names_for_mode, mechanism_names_for_mode,
set_mode, set_mode,
) )
@@ -79,9 +83,9 @@ SETTINGS_PATH = os.path.join(os.path.dirname(os.path.abspath(__file__)), "last_s
# bd_fresnel_core.calc_beam_params for why (faithfully preserved from # bd_fresnel_core.calc_beam_params for why (faithfully preserved from
# the original, not a translation gap). # the original, not a translation gap).
CALC_BEAM_PARAMS_FIELDS = { CALC_BEAM_PARAMS_FIELDS = {
"E_p", "tau_p_FWHM", "w_0p", "lambda_p", "E_e", "tau_e_FWHM", "w_0_e", "lambda_e",
"tau_FWHM", "w_0", "lambda_", "tau_p_FWHM", "w_0_p", "lambda_p",
"R_p", "R", "alpha", "alpha_p", "n", "dndl", "n_p", "dndl_p", "alpha_2d", "R_e", "R_p", "alpha_p", "alpha_e", "n_p", "dndl_p", "n_e", "dndl_e", "alpha_2d_e",
} }
# (field, label, unit, abs_on_entry, log_name) -- mirrors each # (field, label, unit, abs_on_entry, log_name) -- mirrors each
@@ -93,34 +97,34 @@ CALC_BEAM_PARAMS_FIELDS = {
# validation there is permissive -- only NaN is actually rejected at # validation there is permissive -- only NaN is actually rejected at
# entry, faithfully preserved). # entry, faithfully preserved).
PUMP_FIELDS = [ PUMP_FIELDS = [
("E_p", "E_p (pump energy)", "uJ", True), ("E_e", "E_e (pump energy)", "uJ", True),
("tau_p_FWHM", "tau_p_FWHM", "fs", True), ("tau_e_FWHM", "tau_e_FWHM", "fs", True),
("w_0p", "w_0p (pump waist)", "um", True), ("w_0_e", "w_0_e (pump waist)", "um", True),
("lambda_p", "lambda_p (pump)", "nm", True), ("lambda_e", "lambda_e (pump)", "nm", True),
] ]
PROBE_FIELDS = [ PROBE_FIELDS = [
("tau_FWHM", "tau_FWHM", "fs", True), ("tau_p_FWHM", "tau_p_FWHM", "fs", True),
("w_0", "w_0 (probe waist)", "um", True), ("w_0_p", "w_0_p (probe waist)", "um", True),
("lambda_", "lambda (probe)", "nm", True), ("lambda_p", "lambda_p (probe)", "nm", True),
] ]
MAT_PUMP_FIELDS = [ MAT_PUMP_FIELDS = [
("R_e", "R_e (reflectivity)", "0-1", True),
("alpha_e", "alpha_e (absorption)", "cm^-1", True),
("n_e", "n_e (index)", "", True),
("dndl_e", "dndl_e (dispersion)", "um^-1", False),
("alpha_2d_e", "alpha_2d_e (2PA)", "e-11 m/W", False),
]
MAT_PROBE_FIELDS = [
("R_p", "R_p (reflectivity)", "0-1", True), ("R_p", "R_p (reflectivity)", "0-1", True),
("alpha_p", "alpha_p (absorption)", "cm^-1", True), ("alpha_p", "alpha_p (absorption)", "cm^-1", True),
("n_p", "n_p (index)", "", True), ("n_p", "n_p (index)", "", True),
("dndl_p", "dndl_p (dispersion)", "um^-1", False), ("dndl_p", "dndl_p (dispersion)", "um^-1", False),
("alpha_2d", "alpha_2d (2PA)", "e-11 m/W", False),
]
MAT_PROBE_FIELDS = [
("R", "R (reflectivity)", "0-1", True),
("alpha", "alpha (absorption)", "cm^-1", True),
("n", "n (index)", "", True),
("dndl", "dndl (dispersion)", "um^-1", False),
] ]
SYSTEM_FIELDS = [ SYSTEM_FIELDS = [
("l", "l (thickness)", "mm", True), ("l", "l (thickness)", "mm", True),
("d", "d (sample->detector)", "cm", True), ("d", "d (sample->detector)", "cm", True),
("shift", "shift (delay zero)", "fs", False), ("shift", "shift (delay zero)", "fs", False),
("x_0", "x_0 (pump-probe offset)", "w_0p", False), ("x_0", "x_0 (pump-probe offset)", "w_0_e", False),
] ]
# Escape sequences accepted in the Delimiter field. A literal tab # Escape sequences accepted in the Delimiter field. A literal tab
@@ -148,14 +152,17 @@ def describe_delimiter(text: str) -> str:
# The simulation grid, in the order shown in the "Simulation # The simulation grid, in the order shown in the "Simulation
# parameters" box: (attribute, label, unit, kind). Integer fields are # parameters" box: (attribute, label, unit, kind). Integer fields are
# counts and must be >= 1; the float fields are extents and cannot be # counts and must be >= 1; the float fields are extents and cannot be
# negative. T_d_min/T_d_max are deliberately absent -- they are taken # negative. T_d_min/T_d_max are signed and are entered only in
# from the imported scan's delay range, not entered. # Simulation mode; in Fitting mode they are taken from the imported
# scan's delay range and the fields are disabled.
SIM_FIELDS = [ SIM_FIELDS = [
("X_num", "X_num (spatial pts)", "points", "int"), ("X_num", "X_num (spatial pts)", "points", "int"),
("X_max", "X_max (spatial extent)", "w_0", "float"), ("X_max", "X_max (spatial extent)", "w_0_p", "float"),
("T_num", "T_num (time pts)", "points", "int"), ("T_num", "T_num (time pts)", "points", "int"),
("T_max", "T_max (time extent)", "tau_p", "float"), ("T_max", "T_max (time extent)", "tau_e", "float"),
("T_d_num", "T_d_num (delay pts)", "points", "int"), ("T_d_num", "T_d_num (delay pts)", "points", "int"),
("T_d_min", "T_d_min (delay start)", "tau_e", "signed"),
("T_d_max", "T_d_max (delay end)", "tau_e", "signed"),
] ]
# The numeric parameter boxes, in panel order. Each entry is # The numeric parameter boxes, in panel order. Each entry is
@@ -177,7 +184,7 @@ FIELD_IS_NONNEGATIVE = {
for name, _label, _unit, nonneg in fields for name, _label, _unit, nonneg in fields
} }
FIELD_IS_NONNEGATIVE.update( FIELD_IS_NONNEGATIVE.update(
{name: True for name, _l, _u, kind in SIM_FIELDS if kind == "float"}) {name: kind == "float" for name, _l, _u, kind in SIM_FIELDS if kind != "int"})
class ColumnConflict(ValueError): class ColumnConflict(ValueError):
"""Two quantities are set to read from the same data column. Kept """Two quantities are set to read from the same data column. Kept
@@ -185,7 +192,8 @@ class ColumnConflict(ValueError):
state while swapping two column numbers, one field at a time.""" state while swapping two column numbers, one field at a time."""
# The "Mode" box's radio buttons, in display order: (mode, label). The # The "Operation mode" box's radio buttons, in display order:
# (mode, label). The
# labels are also what the parameter log records. # labels are also what the parameter log records.
MODE_CHOICES = [ MODE_CHOICES = [
(MODE_BEAM_DEFLECTION, "Beam deflection"), (MODE_BEAM_DEFLECTION, "Beam deflection"),
@@ -193,6 +201,24 @@ MODE_CHOICES = [
] ]
MODE_LABELS = dict(MODE_CHOICES) MODE_LABELS = dict(MODE_CHOICES)
# The run-mode toggle, drawn below the measurement-mode one in the same
# box. Fitting compares against an imported scan; Simulation computes
# the signal from the parameters alone.
RUN_MODE_CHOICES = [
(RUN_MODE_FITTING, "Fitting"),
(RUN_MODE_SIMULATION, "Simulation"),
]
RUN_MODE_LABELS = dict(RUN_MODE_CHOICES)
# The algorithm toggle, drawn below the run-mode one. Fresnel
# propagation is the original method; Semi-analytical uses closed-form
# detector expressions and integrates only over time.
ALGO_CHOICES = [
(ALGO_FRESNEL, "Fresnel propagation"),
(ALGO_SEMI_ANALYTICAL, "Semi-analytical"),
]
ALGO_LABELS = dict(ALGO_CHOICES)
# Which column of the imported file feeds each quantity. 1-based, in # Which column of the imported file feeds each quantity. 1-based, in
# the order they are shown in the "Data columns" box. # the order they are shown in the "Data columns" box.
DATA_COLUMN_FIELDS = [ DATA_COLUMN_FIELDS = [
@@ -271,11 +297,19 @@ class LabeledEntry(ttk.Frame):
class LabeledStatic(ttk.Frame): class LabeledStatic(ttk.Frame):
"""Read-only calculated-value display (e.g. rho, I_0_p).""" """Read-only calculated-value display (e.g. rho, I_0_e)."""
# Widest label in use is "I_0_e (peak irradiance)" at 23
# characters. The width is a minimum request, not a clip, so a
# label longer than this does not truncate -- it pushes its own
# value right and breaks the column alignment, which is what
# happened when the T_lin labels gained "(transmission)".
LABEL_WIDTH = 23
def __init__(self, parent, label): def __init__(self, parent, label):
super().__init__(parent) super().__init__(parent)
ttk.Label(self, text=label, width=20, anchor="w").pack(side="left") ttk.Label(self, text=label, width=self.LABEL_WIDTH,
anchor="w").pack(side="left")
self.var = tk.StringVar(value="--") self.var = tk.StringVar(value="--")
ttk.Label(self, textvariable=self.var, width=16, anchor="w", ttk.Label(self, textvariable=self.var, width=16, anchor="w",
foreground="black").pack(side="left") foreground="black").pack(side="left")
@@ -383,7 +417,7 @@ class BDFresnelApp(tk.Tk):
self.params = self._load_or_default_params() self.params = self._load_or_default_params()
self.data = None # dict with tau_d, tau_d_shifted, T, DeltaEoE, Delta_n self.data = None # dict with tau_d, tau_d_shifted, T, DeltaEoE, Delta_n
self.fit = None # dict, output of BD_Fresnel_func_ni self.fit = None # dict, output of BD_Fresnel_run
# The file loaded this session, if any. A mode change re-reads # The file loaded this session, if any. A mode change re-reads
# it, since the two modes need different columns. Kept even if # it, since the two modes need different columns. Kept even if
# that re-read fails, so switching back can load it again. # that re-read fails, so switching back can load it again.
@@ -537,6 +571,23 @@ class BDFresnelApp(tk.Tk):
def _build_param_fields(self, parent): def _build_param_fields(self, parent):
self._field_widgets = {} self._field_widgets = {}
sec = add_section(parent, "Operation mode")
self._configure_mode_toggle_style()
# Two toggles stacked in one box: what is being measured, then
# whether a measurement is being fitted at all. Each row is its
# own frame so the pairs stack rather than running together.
self.mode_var = tk.StringVar(value=self.params.mode)
self._mode_buttons = self._build_toggle_row(
sec, MODE_CHOICES, self.mode_var, self._on_mode_change)
self.run_mode_var = tk.StringVar(value=self.params.run_mode)
self._run_mode_buttons = self._build_toggle_row(
sec, RUN_MODE_CHOICES, self.run_mode_var, self._on_run_mode_change,
pady=(3, 0))
self.algorithm_var = tk.StringVar(value=self.params.algorithm)
self._algorithm_buttons = self._build_toggle_row(
sec, ALGO_CHOICES, self.algorithm_var, self._on_algorithm_change,
pady=(3, 0))
sec = add_section(parent, "Data columns") sec = add_section(parent, "Data columns")
for name, label in DATA_COLUMN_FIELDS: for name, label in DATA_COLUMN_FIELDS:
w = LabeledEntry(sec, label, getattr(self.params, name), width=6, w = LabeledEntry(sec, label, getattr(self.params, name), width=6,
@@ -549,21 +600,16 @@ class BDFresnelApp(tk.Tk):
w.pack(fill="x", pady=2) w.pack(fill="x", pady=2)
self._field_widgets["delimiter"] = w self._field_widgets["delimiter"] = w
sec = add_section(parent, "Mode")
self._configure_mode_toggle_style()
self.mode_var = tk.StringVar(value=self.params.mode)
self._mode_buttons = []
width = max(len(label) for _, label in MODE_CHOICES)
for mode, label in MODE_CHOICES:
b = ttk.Radiobutton(sec, text=label, value=mode, variable=self.mode_var,
command=self._on_mode_change, style="Mode.Toolbutton",
width=width)
b.pack(side="left") # abutting, so the pair reads as one control
self._mode_buttons.append(b)
sec = add_section(parent, "Simulation parameters") sec = add_section(parent, "Simulation parameters")
for name, label, unit, kind in SIM_FIELDS: for name, label, unit, kind in SIM_FIELDS:
if kind == "int": if kind == "signed":
# Delay range: entered only in Simulation mode, where
# there is no file to take it from. T_d_min is normally
# negative, so no sign restriction here.
w = LabeledEntry(sec, label, getattr(self.params, name),
width=6, unit=unit,
on_change=lambda n=name: self._on_field_change(n))
elif kind == "int":
w = LabeledEntry(sec, label, getattr(self.params, name), w = LabeledEntry(sec, label, getattr(self.params, name),
width=6, unit=unit, integer=True, width=6, unit=unit, integer=True,
on_change=lambda n=name: self._on_int_field_change(n)) on_change=lambda n=name: self._on_int_field_change(n))
@@ -596,26 +642,42 @@ class BDFresnelApp(tk.Tk):
command=self._on_diagnostics_change).pack(anchor="w") command=self._on_diagnostics_change).pack(anchor="w")
sec = add_section(parent, "Calculated Parameters (probe)") sec = add_section(parent, "Calculated Parameters (probe)")
self.calc_ng = LabeledStatic(sec, "n_g (group index)") self.calc_ng_p = LabeledStatic(sec, "n_g_p (group index)")
self.calc_ng.pack(fill="x", pady=1) self.calc_ng_p.pack(fill="x", pady=1)
self.calc_Tlin = LabeledStatic(sec, "T_lin") self.calc_Tlin_p = LabeledStatic(sec, "T_lin_p (transmission)")
self.calc_Tlin.pack(fill="x", pady=1) self.calc_Tlin_p.pack(fill="x", pady=1)
self.calc_z0 = LabeledStatic(sec, "z_0 (Rayleigh range)") self.calc_z0_p = LabeledStatic(sec, "z_0_p (Rayleigh range)")
self.calc_z0.pack(fill="x", pady=1) self.calc_z0_p.pack(fill="x", pady=1)
# Pump side is subscripted _e, probe side bare, matching the
# field names and the log.
sec = add_section(parent, "Calculated Parameters (pump)") sec = add_section(parent, "Calculated Parameters (pump)")
self.calc_ngp = LabeledStatic(sec, "n_g (group index)") self.calc_ng_e = LabeledStatic(sec, "n_g_e (group index)")
self.calc_ngp.pack(fill="x", pady=1) self.calc_ng_e.pack(fill="x", pady=1)
self.calc_Tlinp = LabeledStatic(sec, "T_lin") self.calc_sigma_e = LabeledStatic(sec, "sigma_e (absorption)")
self.calc_Tlinp.pack(fill="x", pady=1) self.calc_sigma_e.pack(fill="x", pady=1)
self.calc_z0p = LabeledStatic(sec, "z_0 (Rayleigh range)") self.calc_Tlin_e = LabeledStatic(sec, "T_lin_e (transmission)")
self.calc_z0p.pack(fill="x", pady=1) self.calc_Tlin_e.pack(fill="x", pady=1)
self.calc_I0p = LabeledStatic(sec, "I_0 (peak irradiance)") self.calc_z0_e = LabeledStatic(sec, "z_0_e (Rayleigh range)")
self.calc_I0p.pack(fill="x", pady=1) self.calc_z0_e.pack(fill="x", pady=1)
self.calc_I0_e = LabeledStatic(sec, "I_0_e (peak irradiance)")
self.calc_I0_e.pack(fill="x", pady=1)
sec = add_section(parent, "Other") sec = add_section(parent, "Other")
self.calc_rho = LabeledStatic(sec, "rho (GVM parameter)") self.calc_rho = LabeledStatic(sec, "rho (GVM parameter)")
self.calc_rho.pack(fill="x", pady=1) self.calc_rho.pack(fill="x", pady=1)
# Unlike every other value in these panels, which is derived
# from the parameters alone and so updates as they are typed,
# eta and Gamma come from the result: they are peaks over the
# whole (T, T_d) grid, which there is no way to get without
# running the calculation. They therefore read "--" until a Fit
# or Simulate completes, and go back to "--" whenever that
# result is discarded, so a stale phase is never shown beside
# freshly edited parameters. See _refresh_result_values.
self.calc_eta = LabeledStatic(sec, "eta (peak)")
self.calc_eta.pack(fill="x", pady=1)
self.calc_Gamma = LabeledStatic(sec, "Gamma (peak)")
self.calc_Gamma.pack(fill="x", pady=1)
# ------------------------------------------------------------------ # ------------------------------------------------------------------
# Field / state synchronization # Field / state synchronization
@@ -636,24 +698,70 @@ class BDFresnelApp(tk.Tk):
# ------------------------------------------------------------------ # ------------------------------------------------------------------
def _apply_mode_to_widgets(self): def _apply_mode_to_widgets(self):
"""Makes the panel reflect self.params.mode: the selected radio """Makes the panel reflect self.params.mode and .run_mode: the
button, whether x_0 can be edited (pump probe fixes it at 0), selected radio buttons, whether x_0 can be edited (pump probe
and which mechanisms each pull-down offers.""" fixes it at 0), which mechanisms each pull-down offers, and
which inputs Simulation mode takes over or gives up."""
mode = self.params.mode mode = self.params.mode
simulating = self.params.run_mode == RUN_MODE_SIMULATION
self.mode_var.set(mode) self.mode_var.set(mode)
self.run_mode_var.set(self.params.run_mode)
self._field_widgets["x_0"].set_enabled(mode == MODE_BEAM_DEFLECTION) self._field_widgets["x_0"].set_enabled(mode == MODE_BEAM_DEFLECTION)
# Pump probe reads no deflection column, so its number is moot.
self._field_widgets["col_DeltaEoE"].set_enabled(mode == MODE_BEAM_DEFLECTION)
choices = mechanism_names_for_mode(mode) choices = mechanism_names_for_mode(mode)
for row in self._mechanism_rows: for row in self._mechanism_rows:
row.set_choices(choices) row.set_choices(choices)
# Simulation reads no file, so the column numbers and delimiter
# have nothing to describe.
for name in ("col_tau_d", "col_T", "delimiter"):
self._field_widgets[name].set_enabled(not simulating)
# Pump probe reads no deflection column, so its number is moot.
self._field_widgets["col_DeltaEoE"].set_enabled(
mode == MODE_BEAM_DEFLECTION and not simulating)
# The delay range is entered only when there is no scan to take
# it from; in Fitting mode it is overwritten at fit time.
for name in ("T_d_min", "T_d_max"):
self._field_widgets[name].set_enabled(simulating)
# The semi-analytical expressions are already integrated over
# the detector plane, so there is no spatial grid to size.
for name in ("X_num", "X_max"):
self._field_widgets[name].set_enabled(
self.params.algorithm != ALGO_SEMI_ANALYTICAL)
self.algorithm_var.set(self.params.algorithm)
self.import_button.config(state="disabled" if simulating else "normal")
self.fit_button.config(text=self.run_action_label)
# Selection colour of Tk's "default" theme (its radio-button # Selection colour of Tk's "default" theme (its radio-button
# indicator), so the toggle matches the rest of the panel. # indicator), so the toggle matches the rest of the panel.
MODE_SELECTED_BG = "#4a6984" MODE_SELECTED_BG = "#4a6984"
@staticmethod
def _build_toggle_row(parent, choices, variable, command, pady=0):
"""One segmented toggle: equal-width buttons packed edge to edge
so the pair reads as a single control. Returns the buttons.
The width is taken across both toggles' labels, not just this
row's, so the two rows line up as one block."""
row = ttk.Frame(parent)
row.pack(anchor="w", pady=pady)
width = max(len(label)
for group in (MODE_CHOICES, RUN_MODE_CHOICES, ALGO_CHOICES)
for _, label in group)
buttons = []
for value, label in choices:
b = ttk.Radiobutton(row, text=label, value=value, variable=variable,
command=command, style="Mode.Toolbutton",
width=width)
b.pack(side="left")
buttons.append(b)
return buttons
def _configure_mode_toggle_style(self): def _configure_mode_toggle_style(self):
"""The Mode box's two radio buttons drawn as a segmented toggle: """The Operation mode box's two radio buttons drawn as a segmented toggle:
a pair of equal-width buttons, the selected one filled. a pair of equal-width buttons, the selected one filled.
Built on ttk's Toolbutton, but with a border on both states. Built on ttk's Toolbutton, but with a border on both states.
@@ -678,9 +786,72 @@ class BDFresnelApp(tk.Tk):
("disabled", "#a3a3a3"), ("disabled", "#a3a3a3"),
("selected", "white")]) ("selected", "white")])
@property
def run_action_label(self):
"""What the Fit button is called in the current run mode."""
return ("Simulate" if self.params.run_mode == RUN_MODE_SIMULATION
else "Fit")
def _on_mode_change(self): def _on_mode_change(self):
self._set_mode(self.mode_var.get()) self._set_mode(self.mode_var.get())
def _on_run_mode_change(self):
self._set_run_mode(self.run_mode_var.get())
def _on_algorithm_change(self):
self._set_algorithm(self.algorithm_var.get())
def _set_algorithm(self, algorithm):
"""Switches between Fresnel propagation and the semi-analytical
expressions. Any result on screen is discarded: it was computed
by the other method, and the point of having both is to compare
them deliberately rather than to leave one mislabelled."""
if algorithm == self.params.algorithm:
return # Tk fires on every click, re-selection included
self.params.algorithm = algorithm
self.params.data_fit = False
self.fit = None
self._refresh_param_fields_from_state()
self._refresh_plots()
self._refresh_diagnostics()
self._update_action_buttons()
self._save_settings()
message = f"Algorithm: {ALGO_LABELS[algorithm]}."
self.status_var.set(message)
print(f"bd_fresnel_gui: {message}")
def _set_run_mode(self, run_mode):
"""Switches between fitting an imported scan and simulating
without one. Any result on screen is discarded: a fit describes
a measurement that Simulation mode does not show, and a
simulation was computed over a hand-entered delay range that
Fitting mode replaces with the file's."""
if run_mode == self.params.run_mode:
return # Tk fires on every click, re-selection included
self.params.run_mode = run_mode
simulating = run_mode == RUN_MODE_SIMULATION
# The imported scan is kept in params while simulating, so
# switching back restores it rather than asking for it again.
if simulating:
self.data = None
else:
self._reread_session_file("could not be read again")
self.params.data_fit = False
self.fit = None
self._refresh_param_fields_from_state()
self._refresh_plots()
self._refresh_diagnostics()
self._update_action_buttons()
self._save_settings()
message = f"Operation mode: {RUN_MODE_LABELS[run_mode]}."
if simulating:
message += " No data is imported; the delay range is set by T_d_min/T_d_max."
self.status_var.set(message)
print(f"bd_fresnel_gui: {message}")
def _set_mode(self, mode): def _set_mode(self, mode):
"""Switches mode, then brings the panel, plots and buttons into """Switches mode, then brings the panel, plots and buttons into
line with it. Any fit on screen is discarded: it was computed line with it. Any fit on screen is discarded: it was computed
@@ -701,7 +872,7 @@ class BDFresnelApp(tk.Tk):
self._update_action_buttons() self._update_action_buttons()
self._save_settings() self._save_settings()
message = f"Mode: {MODE_LABELS[mode]}." message = f"Operation mode: {MODE_LABELS[mode]}."
if cleared: if cleared:
slots = ", ".join(str(i + 1) for i in cleared) slots = ", ".join(str(i + 1) for i in cleared)
message += (f" Purely refractive mechanism(s) in slot {slots} set aside;" message += (f" Purely refractive mechanism(s) in slot {slots} set aside;"
@@ -714,8 +885,8 @@ class BDFresnelApp(tk.Tk):
def _set_mode_buttons_enabled(self, enabled: bool): def _set_mode_buttons_enabled(self, enabled: bool):
"""The fit runs on a worker thread that reads self.params """The fit runs on a worker thread that reads self.params
throughout, so the mode must not change underneath it.""" throughout, so neither mode must change underneath it."""
for b in self._mode_buttons: for b in self._mode_buttons + self._run_mode_buttons + self._algorithm_buttons:
b.state(["!disabled"] if enabled else ["disabled"]) b.state(["!disabled"] if enabled else ["disabled"])
def _on_field_change(self, field_name): def _on_field_change(self, field_name):
@@ -870,32 +1041,54 @@ class BDFresnelApp(tk.Tk):
def _recalc_beam_params(self, refresh_display=False): def _recalc_beam_params(self, refresh_display=False):
calc_beam_params(self.params) calc_beam_params(self.params)
if refresh_display: if refresh_display:
self.calc_ng.set(f"{self.params.ng:.3f}") self.calc_ng_p.set(f"{self.params.ng_p:.3f}")
self.calc_Tlin.set(f"{self.params.Tlin:.3f}") self.calc_Tlin_p.set(f"{self.params.Tlin_p:.3f}")
self.calc_z0.set(f"{self.params.z_0 * 1e3:.3f} mm") self.calc_z0_p.set(f"{self.params.z_0_p * 1e3:.3f} mm")
self.calc_ngp.set(f"{self.params.ng_p:.3f}") self.calc_ng_e.set(f"{self.params.ng_e:.3f}")
self.calc_Tlinp.set(f"{self.params.Tlin_p:.3f}") self.calc_sigma_e.set(f"{self.params.sigma_e:.3f}")
self.calc_z0p.set(f"{self.params.z_0_p * 1e3:.3f} mm") self.calc_Tlin_e.set(f"{self.params.Tlin_e:.3f}")
self.calc_I0p.set(f"{self.params.I_0_p * 1e-13:.3f} GW/cm^2") self.calc_z0_e.set(f"{self.params.z_0_e * 1e3:.3f} mm")
self.calc_I0_e.set(f"{self.params.I_0_e * 1e-13:.3f} GW/cm^2")
self.calc_rho.set(f"{self.params.rho:.3f}") self.calc_rho.set(f"{self.params.rho:.3f}")
def _update_fit_button_state(self): def _update_fit_button_state(self):
"""Fit needs both a data file (it takes its delay range from """Fit needs a data file (it takes its delay range from the
the imported scan) and a valid set of beam/material inputs.""" imported scan) and a valid set of beam/material inputs.
ready = self.data is not None and inputs_valid(self.params) Simulate needs only the inputs -- its delay range is entered."""
simulating = self.params.run_mode == RUN_MODE_SIMULATION
ready = (inputs_valid(self.params, require_data=not simulating)
and (simulating or self.data is not None))
self.fit_button.config(state="normal" if ready else "disabled") self.fit_button.config(state="normal" if ready else "disabled")
def _update_export_button_state(self): def _update_export_button_state(self):
"""Export writes the data/fit comparison table and the plot """Export writes the plot image and a data table, so it stays
image, so it stays disabled until a fit has actually disabled until a fit or simulation has actually completed.
completed. Importing a new file clears the fit and disables it Importing a new file, or changing mode, clears the result and
again.""" disables it again."""
ready = self.data is not None and self.fit is not None ready = self.fit is not None and (
self.params.run_mode == RUN_MODE_SIMULATION or self.data is not None)
self.export_button.config(state="normal" if ready else "disabled") self.export_button.config(state="normal" if ready else "disabled")
def _update_action_buttons(self): def _update_action_buttons(self):
self._update_fit_button_state() self._update_fit_button_state()
self._update_export_button_state() self._update_export_button_state()
self._refresh_result_values()
def _refresh_result_values(self):
"""Fills the result-derived readouts in the "Other" panel, or
blanks them when there is no current result.
Hooked to _update_action_buttons rather than to
_recalc_beam_params because the latter fires only for fields in
CALC_BEAM_PARAMS_FIELDS -- editing a mechanism coefficient
changes eta substantially and would have left a stale value on
screen. Every site that assigns self.fit, including every one
that clears it, already calls _update_action_buttons, so this
cannot be bypassed by a path that forgets to call it."""
fit = self.fit or {}
eta, gamma = fit.get("eta_peak"), fit.get("Gamma_peak")
self.calc_eta.set("--" if eta is None else f"{eta:.3f} rad")
self.calc_Gamma.set("--" if gamma is None else f"{gamma:.3f}")
# ------------------------------------------------------------------ # ------------------------------------------------------------------
# Import # Import
@@ -966,12 +1159,12 @@ class BDFresnelApp(tk.Tk):
T=T, DeltaEoE=None, Delta_n=None) T=T, DeltaEoE=None, Delta_n=None)
DeltaEoE = raw[:, col_DeltaEoE - 1] DeltaEoE = raw[:, col_DeltaEoE - 1]
lambda_ = self.params.lambda_ * 1e-9 lambda_p = self.params.lambda_p * 1e-9
l = self.params.l * 1e-3 l = self.params.l * 1e-3
w_0 = self.params.w_0 * 1e-6 w_0_p = self.params.w_0_p * 1e-6
w_0_p = self.params.w_0p * 1e-6 w_0_e = self.params.w_0_e * 1e-6
k_0 = 2 * np.pi / lambda_ k_0 = 2 * np.pi / lambda_p
Delta_n = DeltaEoE / (k_0 * l * np.sqrt(2 / np.e) * (w_0 / w_0_p) * (2 / np.sqrt(np.pi))) Delta_n = DeltaEoE / (k_0 * l * np.sqrt(2 / np.e) * (w_0_p / w_0_e) * (2 / np.sqrt(np.pi)))
return dict( return dict(
tau_d=tau_d, tau_d=tau_d,
@@ -1017,7 +1210,8 @@ class BDFresnelApp(tk.Tk):
# ------------------------------------------------------------------ # ------------------------------------------------------------------
def _on_fit(self): def _on_fit(self):
if self.data is None: simulating = self.params.run_mode == RUN_MODE_SIMULATION
if self.data is None and not simulating:
return return
self.fit_button.config(state="disabled", text="Processing...") self.fit_button.config(state="disabled", text="Processing...")
self.import_button.config(state="disabled") self.import_button.config(state="disabled")
@@ -1035,8 +1229,12 @@ class BDFresnelApp(tk.Tk):
# since refresh_plots.m/pb_Export_Callback.m both compare # since refresh_plots.m/pb_Export_Callback.m both compare
# against the shifted values. This is a deliberate correction, # against the shifted values. This is a deliberate correction,
# not a faithfulness gap.) # not a faithfulness gap.)
self.params.T_d_min = float(np.min(self.data["tau_d_shifted"])) / self.params.tau_p # In Simulation mode there is no scan to take the range from:
self.params.T_d_max = float(np.max(self.data["tau_d_shifted"])) / self.params.tau_p # T_d_min/T_d_max are the values entered in the panel and are
# left exactly as they are.
if not simulating:
self.params.T_d_min = float(np.min(self.data["tau_d_shifted"])) / self.params.tau_e
self.params.T_d_max = float(np.max(self.data["tau_d_shifted"])) / self.params.tau_e
# T_d_num is no longer forced here -- it is an input in the # T_d_num is no longer forced here -- it is an input in the
# Simulation Parameters box, defaulting to the 150 this line # Simulation Parameters box, defaulting to the 150 this line
# used to hard-code. # used to hard-code.
@@ -1047,7 +1245,7 @@ class BDFresnelApp(tk.Tk):
def _fit_worker(self): def _fit_worker(self):
t0 = time.time() t0 = time.time()
try: try:
fit = BD_Fresnel_func_ni(self.params) fit = BD_Fresnel_run(self.params)
elapsed = time.time() - t0 elapsed = time.time() - t0
self.after(0, self._on_fit_success, fit, elapsed) self.after(0, self._on_fit_success, fit, elapsed)
except Exception: except Exception:
@@ -1063,18 +1261,22 @@ class BDFresnelApp(tk.Tk):
self.log_text.delete("1.0", "end") self.log_text.delete("1.0", "end")
self.log_text.insert("1.0", self._build_log_text()) self.log_text.insert("1.0", self._build_log_text())
self.fit_button.config(text="Fit") self.fit_button.config(text=self.run_action_label)
self.import_button.config(state="normal") self.import_button.config(
state="disabled" if self.params.run_mode == RUN_MODE_SIMULATION else "normal")
self._set_mode_buttons_enabled(True) self._set_mode_buttons_enabled(True)
self._update_action_buttons() self._update_action_buttons()
self.progress.stop() self.progress.stop()
self.status_var.set(f"Fit complete in {elapsed:.2f} s.") done = ("Simulation" if self.params.run_mode == RUN_MODE_SIMULATION
print(f"bd_fresnel_gui: fitting complete. Elapsed time: {elapsed:.2f} s.") else "Fit")
self.status_var.set(f"{done} complete in {elapsed:.2f} s.")
print(f"bd_fresnel_gui: {done.lower()} complete. Elapsed time: {elapsed:.2f} s.")
self._save_settings() self._save_settings()
def _on_fit_error(self, tb_text): def _on_fit_error(self, tb_text):
self.fit_button.config(text="Fit") self.fit_button.config(text=self.run_action_label)
self.import_button.config(state="normal") self.import_button.config(
state="disabled" if self.params.run_mode == RUN_MODE_SIMULATION else "normal")
self._set_mode_buttons_enabled(True) self._set_mode_buttons_enabled(True)
# Export stays available only if an earlier fit succeeded and # Export stays available only if an earlier fit succeeded and
# is still on screen; _update_export_button_state decides. # is still on screen; _update_export_button_state decides.
@@ -1094,6 +1296,12 @@ class BDFresnelApp(tk.Tk):
"""Computes the data/fit arrays, axis scale, and shared axis """Computes the data/fit arrays, axis scale, and shared axis
ranges used by every plot (the two live tabs and the combined ranges used by every plot (the two live tabs and the combined
export image), so they all stay perfectly consistent.""" export image), so they all stay perfectly consistent."""
# Simulation mode has no measurement: the calculated curve
# supplies the delay axis, and there are no markers to size.
simulating = self.data is None
if simulating:
tau_d = tau_d_shifted = self.fit["tau_d"]
else:
tau_d = self.data["tau_d"] tau_d = self.data["tau_d"]
tau_d_shifted = self.data["tau_d_shifted"] tau_d_shifted = self.data["tau_d_shifted"]
n_pts = len(tau_d) n_pts = len(tau_d)
@@ -1118,10 +1326,15 @@ class BDFresnelApp(tk.Tk):
tau_d_disp = tau_d_shifted / scale tau_d_disp = tau_d_shifted / scale
has_fit = self.fit is not None and self.params.data_fit has_fit = self.fit is not None and self.params.data_fit
# Pump-probe data carries no deflection column, and has no # Pump probe carries no deflection column, and has no Deflection
# Deflection panel to size. # panel to size.
has_deflection = self.data["DeltaEoE"] is not None has_deflection = (self.params.mode == MODE_BEAM_DEFLECTION if simulating
if has_fit: else self.data["DeltaEoE"] is not None)
if simulating:
fit_tau_d_disp = self.fit["tau_d"] / scale
T_points = self.fit["T"]
DeltaEoE_points = self.fit["DeltaEoE"] if has_deflection else None
elif has_fit:
fit_tau_d_disp = self.fit["tau_d"] / scale fit_tau_d_disp = self.fit["tau_d"] / scale
T_points = np.concatenate([self.data["T"], self.fit["T"]]) T_points = np.concatenate([self.data["T"], self.fit["T"]])
DeltaEoE_points = (np.concatenate([self.data["DeltaEoE"], self.fit["DeltaEoE"]]) DeltaEoE_points = (np.concatenate([self.data["DeltaEoE"], self.fit["DeltaEoE"]])
@@ -1142,6 +1355,7 @@ class BDFresnelApp(tk.Tk):
return dict( return dict(
tau_d_disp=tau_d_disp, fit_tau_d_disp=fit_tau_d_disp, has_fit=has_fit, tau_d_disp=tau_d_disp, fit_tau_d_disp=fit_tau_d_disp, has_fit=has_fit,
has_data=not simulating,
marker_size=marker_size, marker_size=marker_size,
T_points=T_points, DeltaEoE_points=DeltaEoE_points, T_points=T_points, DeltaEoE_points=DeltaEoE_points,
x_min=x_min, x_max=x_max, scale_label=scale_label, x_min=x_min, x_max=x_max, scale_label=scale_label,
@@ -1326,7 +1540,9 @@ class BDFresnelApp(tk.Tk):
"""Legend entries listed as Data over Fit, independent of the """Legend entries listed as Data over Fit, independent of the
order the artists were drawn in (the fit is plotted first so order the artists were drawn in (the fit is plotted first so
the data markers sit on top of it).""" the data markers sit on top of it)."""
handles = [data_line] + ([fit_line] if fit_line is not None else []) handles = [h for h in (data_line, fit_line) if h is not None]
if not handles:
return
ax.legend(handles=handles, labels=[h.get_label() for h in handles], ax.legend(handles=handles, labels=[h.get_label() for h in handles],
loc="lower right") loc="lower right")
@@ -1336,10 +1552,11 @@ class BDFresnelApp(tk.Tk):
# and drawn by one method. # and drawn by one method.
PANELS = { PANELS = {
"T": dict(key="T", color=TRANSMISSION_COLOR, ylabel="T (%)", "T": dict(key="T", color=TRANSMISSION_COLOR, ylabel="T (%)",
title="Transmission", range_key="T_points"), title="Transmission", range_key="T_points",
y_sig_figs=3),
"DeltaEoE": dict(key="DeltaEoE", color=DEFLECTION_COLOR, "DeltaEoE": dict(key="DeltaEoE", color=DEFLECTION_COLOR,
ylabel=r"$\Delta E/E$ (%)", title="Deflection", ylabel=r"$\Delta E/E$ (%)", title="Deflection",
range_key="DeltaEoE_points"), range_key="DeltaEoE_points", y_sig_figs=None),
} }
def _plot_signal_axis(self, ax, ctx, which, y_on_right=False): def _plot_signal_axis(self, ax, ctx, which, y_on_right=False):
@@ -1351,15 +1568,24 @@ class BDFresnelApp(tk.Tk):
the data's delay range and should be cut off at the border the data's delay range and should be cut off at the border
rather than overflow it. rather than overflow it.
""" """
from matplotlib.ticker import FuncFormatter
spec = self.PANELS[which] spec = self.PANELS[which]
key, color = spec["key"], spec["color"] key, color = spec["key"], spec["color"]
fit_line = None fit_line = None
if ctx["has_fit"]: if ctx["has_fit"]:
# "Simulated" rather than "Fit" when there is no
# measurement it could be a fit to.
fit_line, = ax.plot(ctx["fit_tau_d_disp"], 100 * self.fit[key], fit_line, = ax.plot(ctx["fit_tau_d_disp"], 100 * self.fit[key],
linestyle="-", color=color, label="Fit") linestyle="-", color=color,
label="Fit" if ctx["has_data"] else "Simulated")
fit_line.set_clip_on(True) fit_line.set_clip_on(True)
fit_line.set_clip_path(ax.patch) fit_line.set_clip_path(ax.patch)
# Simulation mode plots the calculated curve alone -- there is
# no measurement, so no markers and no "Data" legend entry.
data_line = None
if ctx["has_data"]:
data_line, = ax.plot(ctx["tau_d_disp"], 100 * self.data[key], data_line, = ax.plot(ctx["tau_d_disp"], 100 * self.data[key],
linestyle="none", marker="o", color=color, linestyle="none", marker="o", color=color,
markeredgewidth=0, markeredgewidth=0,
@@ -1373,13 +1599,37 @@ class BDFresnelApp(tk.Tk):
ax.set_xlabel(rf"$\tau_d$ ({ctx['scale_label']})") ax.set_xlabel(rf"$\tau_d$ ({ctx['scale_label']})")
ax.set_ylabel(spec["ylabel"]) ax.set_ylabel(spec["ylabel"])
ax.set_title(spec["title"]) # size from rc context ax.set_title(spec["title"]) # size from rc context
sig = spec.get("y_sig_figs")
if sig is not None:
# Transmission sits near 100%, so the default formatter
# spends most of its digits on the leading "99." and the
# labels get wide. "%.<n>g" keeps the stated number of
# significant digits instead.
#
# The requested count is a floor, not a cap: a shallow scan
# spanning, say, 99.94 to 100% rounds every tick to "100"
# at three figures, leaving an unreadable axis. Digits are
# added only when that would happen, so an ordinary scan
# gets exactly the figures asked for.
ticks = [t for t in ax.get_yticks()
if min(ax.get_ylim()) <= t <= max(ax.get_ylim())]
while sig < 10 and len({f"{t:.{sig}g}" for t in ticks}) < len(ticks):
sig += 1
ax.yaxis.set_major_formatter(
FuncFormatter(lambda value, _pos, n=sig: f"{value:.{n}g}"))
if y_on_right: if y_on_right:
ax.yaxis.tick_right() ax.yaxis.tick_right()
ax.yaxis.set_label_position("right") ax.yaxis.set_label_position("right")
self._order_legend(ax, data_line, fit_line) self._order_legend(ax, data_line, fit_line)
def _refresh_plots(self): def _refresh_plots(self):
if self.data is None: # Fitting shows the measurement as soon as it is imported;
# Simulation has nothing to show until it has been run.
if self.data is None and self.fit is None:
for child in self.plot_holder.winfo_children():
child.destroy()
self._plot_view = None
return return
fig = self._build_combined_figure() fig = self._build_combined_figure()
@@ -1472,10 +1722,10 @@ class BDFresnelApp(tk.Tk):
# Axis labels as matplotlib mathtext, so Greek letters render as # Axis labels as matplotlib mathtext, so Greek letters render as
# Greek and sub/superscripts sit where they belong rather than # Greek and sub/superscripts sit where they belong rather than
# showing the literal "tau_p" / "m^2" source. Figure *titles* keep # showing the literal "tau_e" / "m^2" source. Figure *titles* keep
# their plain-text form: they double as the Tk frame label and the # their plain-text form: they double as the Tk frame label and the
# export filename, neither of which can render mathtext. # export filename, neither of which can render mathtext.
DIAG_LABEL_T = r"$t$ ($\tau_p$)" DIAG_LABEL_T = r"$t$ ($\tau_e$)"
DIAG_LABEL_R = r"$R[t]$ (m$^2$/W)" DIAG_LABEL_R = r"$R[t]$ (m$^2$/W)"
DIAG_LABEL_A = r"$A[t]$ (m/W)" DIAG_LABEL_A = r"$A[t]$ (m/W)"
DIAG_LABEL_DN = r"$\Delta n$ (unitless)" DIAG_LABEL_DN = r"$\Delta n$ (unitless)"
@@ -1701,11 +1951,15 @@ class BDFresnelApp(tk.Tk):
# ------------------------------------------------------------------ # ------------------------------------------------------------------
def _on_export(self): def _on_export(self):
if self.data is None or self.fit is None: simulating = self.params.run_mode == RUN_MODE_SIMULATION
if self.fit is None or (self.data is None and not simulating):
return return
default_name = self.params.filename.replace(".txt", "_fit.txt") # Simulation has no imported file to name the output after.
default_name = (self.params.filename.replace(".txt", "_fit.txt")
if not simulating else "simulation.txt")
path = filedialog.asksaveasfilename( path = filedialog.asksaveasfilename(
title="Select filename for fit export", title="Select filename for simulation export" if simulating
else "Select filename for fit export",
initialdir=self.params.pathname or os.getcwd(), initialdir=self.params.pathname or os.getcwd(),
initialfile=default_name, initialfile=default_name,
defaultextension=".txt", defaultextension=".txt",
@@ -1716,6 +1970,27 @@ class BDFresnelApp(tk.Tk):
return return
try: try:
if simulating:
# Nothing to interpolate onto and no data columns to
# pair with: the calculated signal is written on its
# own delay grid.
if self.params.mode == MODE_PUMP_PROBE:
export_data = np.column_stack([self.fit["tau_d"], self.fit["T"]])
header = "Delay (fs), T (Simulated)"
else:
export_data = np.column_stack([
self.fit["tau_d"], self.fit["DeltaEoE"],
self.fit["T"], self.fit["Delta_n"]])
header = ("Delay (fs), DeltaE / E (Simulated), "
"T (Simulated), Delta_n (simulated)")
np.savetxt(path, export_data, delimiter=",", fmt="%.8g",
header=header, comments="", newline="\r\n")
image_paths = self._export_plot_images(path)
self._write_export_log(path, image_paths)
print(f"bd_fresnel_gui: export of {path} complete.")
self._save_settings()
return
T_interp = np.interp(self.data["tau_d_shifted"], self.fit["tau_d"], self.fit["T"]) T_interp = np.interp(self.data["tau_d_shifted"], self.fit["tau_d"], self.fit["T"])
if self.params.mode == MODE_PUMP_PROBE: if self.params.mode == MODE_PUMP_PROBE:
# No deflection was imported, so none is exported: the # No deflection was imported, so none is exported: the
@@ -1754,7 +2029,7 @@ class BDFresnelApp(tk.Tk):
pump probe -- plus every diagnostic figure as .jpg when the fit pump probe -- plus every diagnostic figure as .jpg when the fit
was run with diagnostics enabled. Returns the paths written, in was run with diagnostics enabled. Returns the paths written, in
the order written.""" the order written."""
if self.data is None: if self.data is None and self.fit is None:
return [] return []
# Built fresh here rather than reusing the on-screen figure: # Built fresh here rather than reusing the on-screen figure:
@@ -1849,10 +2124,10 @@ class BDFresnelApp(tk.Tk):
omitted). omitted).
Section order matches the GUI's left-panel field order top to Section order matches the GUI's left-panel field order top to
bottom: Data Columns -> Mode -> Simulation grid (not itself a GUI bottom: Operation mode -> Data Columns -> Simulation grid (not
field, kept as a preamble) -> Pump (Excitation) Beam -> Probe itself a GUI field, kept as a preamble) -> Pump (Excitation)
Beam -> Material @ Pump Wavelength -> Material @ Probe Beam -> Probe Beam -> Material @ Pump Wavelength -> Material @
Wavelength -> System Geometry -> Mechanisms -> Calculated Probe Wavelength -> System Geometry -> Mechanisms -> Calculated
Parameters (probe) -> Calculated Parameters (pump) -> Other Parameters (probe) -> Calculated Parameters (pump) -> Other
(rho). The column numbers are 1-based, as entered in the GUI. (rho). The column numbers are 1-based, as entered in the GUI.
""" """
@@ -1861,9 +2136,16 @@ class BDFresnelApp(tk.Tk):
p = self.params p = self.params
lines = [] lines = []
lines.append(f"{datetime.datetime.now()}: Begin beam deflection program (bd_fresnel_gui.py).\n") lines.append(f"{datetime.datetime.now()}: Begin beam deflection program (bd_fresnel_gui.py).\n")
simulating = p.run_mode == RUN_MODE_SIMULATION
# Simulation reads no file, so there is no path and no column
# layout to record.
if not simulating:
lines.append(f"Import data file {p.import_filepath}.\n") lines.append(f"Import data file {p.import_filepath}.\n")
lines.append(f"Mode: {MODE_LABELS[p.mode]}\n") lines.append(f"Operation mode: {MODE_LABELS[p.mode]}, "
f"{RUN_MODE_LABELS[p.run_mode]}\n")
lines.append(f"Algorithm: {ALGO_LABELS[p.algorithm]}\n")
if not simulating:
lines.append("Data Columns:") lines.append("Data Columns:")
lines.append(f" tau_d column: {p.col_tau_d}") lines.append(f" tau_d column: {p.col_tau_d}")
lines.append(f" T column: {p.col_T}") lines.append(f" T column: {p.col_T}")
@@ -1874,49 +2156,50 @@ class BDFresnelApp(tk.Tk):
lines.append(f" Delimiter: {describe_delimiter(p.delimiter)}\n") lines.append(f" Delimiter: {describe_delimiter(p.delimiter)}\n")
# The delay grid is included so a run is reproducible from the # The delay grid is included so a run is reproducible from the
# log alone: T_d_min/T_d_max are not entered but derived from # log alone: in Fitting mode T_d_min/T_d_max are derived from
# the imported scan's delay range at fit time. # the imported scan's delay range at fit time, in Simulation
# mode they are entered directly.
lines.append("Simulation Parameters:") lines.append("Simulation Parameters:")
lines.append(f" X_num: {p.X_num}") lines.append(f" X_num: {p.X_num}")
lines.append(f" X_max: {p.X_max} w_0") lines.append(f" X_max: {p.X_max} w_0")
lines.append(f" T_num: {p.T_num}") lines.append(f" T_num: {p.T_num}")
lines.append(f" T_min: {p.T_min} tau_p") lines.append(f" T_min: {p.T_min} tau_e")
lines.append(f" T_max: {p.T_max} tau_p") lines.append(f" T_max: {p.T_max} tau_e")
lines.append(f" T_d_num: {p.T_d_num}") lines.append(f" T_d_num: {p.T_d_num}")
lines.append(f" T_d_min: {p.T_d_min:.6g} tau_p") lines.append(f" T_d_min: {p.T_d_min:.6g} tau_e")
lines.append(f" T_d_max: {p.T_d_max:.6g} tau_p\n") lines.append(f" T_d_max: {p.T_d_max:.6g} tau_e\n")
lines.append("Pump (Excitation) Beam:") lines.append("Pump (Excitation) Beam:")
lines.append(f" E_p: {p.E_p} uJ") lines.append(f" E_e: {p.E_e} uJ")
lines.append(f" tau_p_FWHM: {p.tau_p_FWHM} fs") lines.append(f" tau_e_FWHM: {p.tau_e_FWHM} fs")
lines.append(f" tau_p (HW1/eM): {p.tau_p:6.3f} fs") lines.append(f" tau_e (HW1/eM): {p.tau_e:6.3f} fs")
lines.append(f" w_0p: {p.w_0p} um") lines.append(f" w_0_e: {p.w_0_e} um")
lines.append(f" lambda_p: {p.lambda_p} nm\n") lines.append(f" lambda_e: {p.lambda_e} nm\n")
lines.append("Probe Beam:") lines.append("Probe Beam:")
lines.append(f" tau_FWHM: {p.tau_FWHM} fs") lines.append(f" tau_p_FWHM: {p.tau_p_FWHM} fs")
lines.append(f" tau (HW1/eM): {p.tau:6.3f} fs") lines.append(f" tau_p (HW1/eM): {p.tau_p:6.3f} fs")
lines.append(f" w_0: {p.w_0} um") lines.append(f" w_0_p: {p.w_0_p} um")
lines.append(f" lambda: {p.lambda_} nm\n") lines.append(f" lambda_p: {p.lambda_p} nm\n")
lines.append("Material @ Pump Wavelength:") lines.append("Material @ Pump Wavelength:")
lines.append(f" R_e: {p.R_e * 100:6.3f} %")
lines.append(f" alpha_e: {p.alpha_e:6.3f} cm^-1")
lines.append(f" n_e: {p.n_e}")
lines.append(f" dndl_e: {p.dndl_e:6.6f} um^-1")
lines.append(f" alpha_2d_e: {p.alpha_2d_e} e-11 m/W\n")
lines.append("Material @ Probe Wavelength:")
lines.append(f" R_p: {p.R_p * 100:6.3f} %") lines.append(f" R_p: {p.R_p * 100:6.3f} %")
lines.append(f" alpha_p: {p.alpha_p:6.3f} cm^-1") lines.append(f" alpha_p: {p.alpha_p:6.3f} cm^-1")
lines.append(f" n_p: {p.n_p}") lines.append(f" n_p: {p.n_p}")
lines.append(f" dndl_p: {p.dndl_p:6.6f} um^-1") lines.append(f" dndl_p: {p.dndl_p:6.6f} um^-1\n")
lines.append(f" alpha_2d: {p.alpha_2d} e-11 m/W\n")
lines.append("Material @ Probe Wavelength:")
lines.append(f" R: {p.R * 100:6.3f} %")
lines.append(f" alpha: {p.alpha:6.3f} cm^-1")
lines.append(f" n: {p.n}")
lines.append(f" dndl: {p.dndl:6.6f} um^-1\n")
lines.append("System Geometry:") lines.append("System Geometry:")
lines.append(f" l: {p.l} mm") lines.append(f" l: {p.l} mm")
lines.append(f" d: {p.d} cm") lines.append(f" d: {p.d} cm")
lines.append(f" shift: {p.shift} fs") lines.append(f" shift: {p.shift} fs")
lines.append(f" x_0: {p.x_0} w_0_p\n") lines.append(f" x_0: {p.x_0} w_0_e\n")
for i, mech in enumerate(p.mech): for i, mech in enumerate(p.mech):
if mech.name == "None (both)": if mech.name == "None (both)":
@@ -1930,18 +2213,39 @@ class BDFresnelApp(tk.Tk):
lines.append("") lines.append("")
lines.append("Calculated Parameters (probe):") lines.append("Calculated Parameters (probe):")
lines.append(f" n_g: {p.ng:6.3f}") lines.append(f" n_g_p: {p.ng_p:6.3f}")
lines.append(f" T_lin: {p.Tlin * 100:6.3f} %") lines.append(f" T_lin_p (transmission): {p.Tlin_p * 100:6.3f} %")
lines.append(f" z_0: {p.z_0 * 1e3:6.3f} mm\n") lines.append(f" z_0_p: {p.z_0_p * 1e3:6.3f} mm\n")
# Pump-side labels carry _e, matching their field names and the
# program-wide convention that the pump is subscripted and the
# probe is bare. The probe block above therefore stays n_g,
# T_lin, z_0. sigma_e sits next to T_lin_e because the two are
# the same statement: with no pump two-photon absorption
# T_lin_e = (1 - R_e) exp(-2 sigma_e). All five read from the
# parameters, not the result, so they report for either
# algorithm.
lines.append("Calculated Parameters (pump):") lines.append("Calculated Parameters (pump):")
lines.append(f" n_g: {p.ng_p:6.3f}") lines.append(f" n_g_e: {p.ng_e:6.3f}")
lines.append(f" T_lin: {p.Tlin_p * 100:6.3f} %") lines.append(f" sigma_e: {p.sigma_e:6.3f}")
lines.append(f" z_0: {p.z_0_p * 1e3:6.3f} mm") lines.append(f" T_lin_e (transmission): {p.Tlin_e * 100:6.3f} %")
lines.append(f" I_0: {p.I_0_p * 1e-13:6.3f} GW/cm^2\n") lines.append(f" z_0_e: {p.z_0_e * 1e3:6.3f} mm")
lines.append(f" I_0_e: {p.I_0_e * 1e-13:6.3f} GW/cm^2\n")
lines.append("Other:") lines.append("Other:")
lines.append(f" rho: {p.rho:6.3f}\n") lines.append(f" rho: {p.rho:6.3f}")
# Peak nonlinear phase and absorption exponent over the whole
# grid, from whichever algorithm produced the current result.
# eta_peak is the small-signal yardstick: the semi-analytical
# dP is first order in the response while Fresnel propagation
# keeps every order, so the two agree only while eta_peak stays
# small. Guarded because a result from an older session's saved
# state may predate these keys.
fit = self.fit or {}
if "eta_peak" in fit:
lines.append(f" eta (peak): {fit['eta_peak']:6.3f} rad")
lines.append(f" Gamma (peak): {fit['Gamma_peak']:6.3f}")
lines.append("")
if exported_files: if exported_files:
# Every file this export run produced. They all land in one # Every file this export run produced. They all land in one
@@ -1956,13 +2260,21 @@ class BDFresnelApp(tk.Tk):
lines.append(f" {os.path.basename(path)}") lines.append(f" {os.path.basename(path)}")
lines.append("") lines.append("")
lines.append("Please cite the following references when using products from this program.\n") lines.append("Please cite the following references when using products from this program.\n")
lines.append(' 1: Reichert, M., et al. (2014). "Temporal, spectral, and polarization ' # Optica style: every author, initials first, abbreviated
'dependence of the nonlinear optical response of carbon disulfide." Optica 1(6): 436.\n') # journal, volume, page range, year. Wrapped with a hanging
lines.append(' 2: Reichert, M., et al. (2014). "Temporal, spectral, and polarization ' # indent rather than run onto one very long line.
'dependence of the nonlinear optical response of carbon disulfide: supplementary ' lines.append(' 1: M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, '
'material." Optica 1(6): 436.\n') 'T. R. Ensley,\n'
lines.append(' 3: Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time ' ' D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and\n'
'and polarization resolved ultrafast nonlinear refraction." Opt Lett 38(18): 3518-3521.\n') ' E. W. Van Stryland, \u201cTemporal, spectral, and polarization '
'dependence of\n'
' the nonlinear optical response of carbon disulfide,\u201d '
'Optica 1, 436\u2013445 (2014).\n')
lines.append(' 2: M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and '
'E. W. Van Stryland,\n'
' \u201cBeam deflection measurement of time and polarization resolved '
'ultrafast\n'
' nonlinear refraction,\u201d Opt. Lett. 38, 3518\u20133521 (2013).\n')
return "\n".join(lines) return "\n".join(lines)
@@ -1972,7 +2284,12 @@ class BDFresnelApp(tk.Tk):
# itself -- everything the export run produced. # itself -- everything the export run produced.
exported = [export_path, *image_paths, log_path] exported = [export_path, *image_paths, log_path]
text = self._build_log_text(exported_files=exported) text = self._build_log_text(exported_files=exported)
with open(log_path, "w+", newline="\r\n") as f: # encoding is explicit: the citation block uses typographic
# quotes and an en dash, and open() otherwise writes in the
# locale's encoding. Windows-1252 happens to contain those
# characters, but latin-1, cp437/cp850 and the CJK code pages
# do not, and would raise UnicodeEncodeError mid-export.
with open(log_path, "w+", newline="\r\n", encoding="utf-8") as f:
f.write(text) f.write(text)
# ------------------------------------------------------------------ # ------------------------------------------------------------------
Binary file not shown.

Before

Width:  |  Height:  |  Size: 124 KiB

After

Width:  |  Height:  |  Size: 355 KiB

+165
View File
@@ -0,0 +1,165 @@
{
"E_e": 1.0,
"tau_e_FWHM": 45.0,
"w_0_e": 142.83,
"lambda_e": 800.0,
"tau_p_FWHM": 100.0,
"w_0_p": 22.253,
"lambda_p": 650.0,
"R_e": 0.0,
"alpha_e": 0.0,
"n_e": 1.4533,
"dndl_e": -0.017284,
"alpha_2d_e": 0.0,
"R_p": 0.0,
"alpha_p": 0.0,
"n_p": 1.4565,
"dndl_p": -0.027158,
"l": 1.72e-06,
"d": 15.0,
"shift": 70.0,
"x_0": 0.5,
"tau_e": 27.025254197695123,
"tau_p": 60.05612043932249,
"sigma_e": 0.0,
"I_0_e": 651473158047437.0,
"ng_e": 1.4671272,
"ng_p": 1.4741526999999999,
"rho": 0.8671350632529666,
"z_0_p": 0.0023933909907098232,
"z_0_e": 0.0801122184130848,
"Tlin_p": 1.0,
"Tlin_e": 1.0,
"X_max": 5.0,
"X_num": 50,
"T_min": -5.0,
"T_max": 5.0,
"T_num": 100,
"T_d_min": -9.579367435592124,
"T_d_max": 39.791355601447556,
"T_d_num": 150,
"n_mech": 7,
"mech": [
{
"name": "Exponential rise/decay (both)",
"param": [
3600.0,
-200000.0,
1.0,
170.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "Exponential rise/decay (both)",
"param": [
15000.0,
-500000.0,
0.1,
10000.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
}
],
"col_tau_d": 1,
"col_DeltaEoE": 2,
"col_T": 3,
"delimiter": ",",
"diagnostics": true,
"data_imported": true,
"data_fit": true,
"mode": "beam_deflection",
"run_mode": "fitting",
"algorithm": "semi_analytical",
"x_0_beam_deflection": 0.5,
"mech_beam_deflection": [],
"filename": "20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
"pathname": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/",
"import_filepath": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
"settings_schema": 3
}
+5
View File
@@ -9,4 +9,9 @@
numpy>=2.0 numpy>=2.0
scipy>=1.6 scipy>=1.6
matplotlib>=3.4 matplotlib>=3.4
# Optional. Only needed for the pump two-photon absorption term
# (alpha_2d_e != 0), which uses the polylogarithm Li_3/2. The core
# imports it lazily, so the program runs without it until that term is
# used, and then says so.
mpmath>=1.2 mpmath>=1.2