Compare commits
9
Commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
1bc882e163 | ||
|
|
50d0d27464 | ||
|
|
45efc8239d | ||
|
|
d7ab1b823e | ||
|
|
98e95180cc | ||
|
|
38c09a4272 | ||
|
|
cc67401de9 | ||
|
|
6d7996ff30 | ||
|
|
61dbd0452b |
+287
-5
@@ -4,7 +4,292 @@ All notable changes to BD Fresnel are documented in this file.
|
|||||||
|
|
||||||
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
||||||
|
|
||||||
## [Unreleased]
|
## [3.0] - 2026-11-14
|
||||||
|
|
||||||
|
### Added
|
||||||
|
|
||||||
|
- **Semi-analytical** algorithm, selectable from a third toggle in the
|
||||||
|
Operation mode box alongside **Fresnel propagation**:
|
||||||
|
- Instead of propagating the exit field to the detector by FFT, it
|
||||||
|
uses closed-form expressions for the power difference and total at
|
||||||
|
the detector, already integrated over the detector plane. Only an
|
||||||
|
integral over time at each delay remains.
|
||||||
|
- The time window runs +/- 5T about each delay, where T = tau_p/tau_e.
|
||||||
|
- Transmission is the energy total normalised to its value before the
|
||||||
|
pump arrives: the first delay point when fitting, and
|
||||||
|
min(-3 rho, -3) tau_e when simulating, so a thin sample with
|
||||||
|
rho -> 0 still normalises away from the peak.
|
||||||
|
- `X_num` and `X_max` are disabled in this mode: the expressions are
|
||||||
|
already integrated over space, so there is no spatial grid.
|
||||||
|
- Applies to both measurement modes. In pump probe the probe is
|
||||||
|
centred, x_0 = 0, so the deflection term vanishes identically and
|
||||||
|
the transmission alone is calculated.
|
||||||
|
- Both algorithms are kept so results can be compared. Switching
|
||||||
|
discards the current result, which belongs to the other method.
|
||||||
|
- The algorithm is saved with the other settings and recorded in the
|
||||||
|
parameter log.
|
||||||
|
- The absorptive term in the deflection expression carries a
|
||||||
|
PROVISIONAL coefficient, `SA_ABSORPTIVE_FACTOR`. As derived, that
|
||||||
|
term matched neither the sign nor the magnitude of the Fresnel
|
||||||
|
result: a purely absorptive mechanism disagreed by a factor of
|
||||||
|
about -69, with correlation exactly -1. Dividing by
|
||||||
|
D = d / (pi w_0_p^2 / lambda_p) = d / z_0_p accounts for the distance and
|
||||||
|
wavelength dependence exactly, and is independent of sample
|
||||||
|
thickness at constant alpha_2_exp*l; the remaining -1/(1 + 2W^2) was
|
||||||
|
measured against the Fresnel path rather than derived. With it the
|
||||||
|
two methods agree to 0.5% for mechanisms with a refractive part and
|
||||||
|
4.5% for purely absorptive ones. It is isolated in one function
|
||||||
|
pending a corrected derivation.
|
||||||
|
|
||||||
|
- The parameter log's `Calculated Parameters (pump)` section reports
|
||||||
|
`sigma_e`, the normalised pump linear absorption `alpha_e * L / 2`.
|
||||||
|
It sits next to `T_lin`, which restates it: with no pump two-photon
|
||||||
|
absorption `T_lin = (1 - R_p) exp(-2 sigma_e)`. Read from the
|
||||||
|
parameters rather than the result, so it is reported for either
|
||||||
|
algorithm.
|
||||||
|
|
||||||
|
- The `Other` panel and the parameter log's `Other` section both report
|
||||||
|
`eta (peak)` and `Gamma (peak)`, the largest nonlinear phase and
|
||||||
|
absorption exponent anywhere on the grid, from whichever algorithm
|
||||||
|
produced the result. These are the only readouts in those panels that
|
||||||
|
come from the result rather than from the parameters, since they are
|
||||||
|
peaks over the whole (T, T_d) grid and cannot be had without running
|
||||||
|
the calculation. They therefore show `--` until a Fit or Simulate
|
||||||
|
completes, and return to `--` whenever that result is discarded, so a
|
||||||
|
stale phase is never displayed beside freshly edited parameters.
|
||||||
|
`eta (peak)` is the yardstick for the semi-analytical algorithm's
|
||||||
|
validity: its `dP` is first order in the response while Fresnel
|
||||||
|
propagation keeps every order, so the two agree only while the phase
|
||||||
|
is small. On the 4-layer mechanisms the peak of `DeltaEoE` sits at
|
||||||
|
the same delay to within 0.0003 tau_e at `eta (peak)` = 0.14, but
|
||||||
|
0.0035 at 1.41, 0.077 at 5.6 and 0.36 at 14.1. Holding `eta (peak)`
|
||||||
|
fixed, the agreement is unaffected by sample thickness (0.05 to
|
||||||
|
2 mm), by walk-off (`rho` 0.04 to 1.7) and by pump absorption
|
||||||
|
(`sigma_e` 0 to 10), so this one number sets the regime. Both
|
||||||
|
algorithms report it to within 2e-5 of each other.
|
||||||
|
|
||||||
|
### Changed
|
||||||
|
|
||||||
|
- **Both beams are now explicitly subscripted: the pump carries `_e`
|
||||||
|
(excitation) and the probe carries `_p`.** This restores the
|
||||||
|
convention the original MATLAB used, which the Python port had
|
||||||
|
partly inverted (`_p` for the pump) and partly dropped (no suffix
|
||||||
|
for the probe). No beam quantity is unsubscripted any more; the only
|
||||||
|
unsuffixed parameters left are the ones belonging to neither beam --
|
||||||
|
the sampling grid, the sample geometry (`l`, `d`, `shift`), the
|
||||||
|
relative offset `x_0`, and the walk-off `rho`.
|
||||||
|
|
||||||
|
| pump: was | now | | probe: was | now |
|
||||||
|
|-----|-----|-|-----|-----|
|
||||||
|
| `E_p` | `E_e` | | `tau_FWHM` | `tau_p_FWHM` |
|
||||||
|
| `tau_p_FWHM` | `tau_e_FWHM` | | `w_0` | `w_0_p` |
|
||||||
|
| `w_0p` | `w_0_e` | | `lambda_` | `lambda_p` |
|
||||||
|
| `lambda_p` | `lambda_e` | | `R` | `R_p` |
|
||||||
|
| `R_p` | `R_e` | | `alpha` | `alpha_p` |
|
||||||
|
| `alpha_p` | `alpha_e` | | `n` | `n_p` |
|
||||||
|
| `n_p` | `n_e` | | `dndl` | `dndl_p` |
|
||||||
|
| `dndl_p` | `dndl_e` | | `tau` | `tau_p` |
|
||||||
|
| `alpha_2d` | `alpha_2d_e` | | `ng` | `ng_p` |
|
||||||
|
| `tau_p` | `tau_e` | | `z_0` | `z_0_p` |
|
||||||
|
| `sigma_p` | `sigma_e` | | `Tlin` | `Tlin_p` |
|
||||||
|
| `I_0_p` | `I_0_e` | | | |
|
||||||
|
| `ng_p` | `ng_e` | | | |
|
||||||
|
| `z_0_p` | `z_0_e` | | | |
|
||||||
|
| `Tlin_p` | `Tlin_e` | | | |
|
||||||
|
| `sigma_p2` / `sigma_p20` | `sigma_e2` / `sigma_e20` | | | |
|
||||||
|
| `a_p_0`, `W_0_p`, `I_p_pulse` | `a_e_0`, `W_0_e`, `I_e_pulse` | | | |
|
||||||
|
|
||||||
|
Note that six probe names -- `tau_p_FWHM`, `lambda_p`, `R_p`,
|
||||||
|
`alpha_p`, `n_p`, `dndl_p` -- are spelled exactly like what were
|
||||||
|
**pump** names before this release. Reading an old log or settings
|
||||||
|
file alongside a new one needs care; see the settings note below for
|
||||||
|
how the program itself is protected.
|
||||||
|
|
||||||
|
The pump pass renamed 389 identifier occurrences textually; the
|
||||||
|
probe pass was done by rewriting 116 exact AST node positions
|
||||||
|
instead, because `n`, `R`, `alpha` and `tau` are overloaded in this
|
||||||
|
codebase (lambda parameters, the author's initials in the copyright
|
||||||
|
line, the semi-analytical formula's geometric `R`, a diagnostics
|
||||||
|
dict key) and no text pattern distinguishes them.
|
||||||
|
|
||||||
|
| was | now | | was | now |
|
||||||
|
|-----|-----|-|-----|-----|
|
||||||
|
| `E_p` | `E_e` | | `tau_p` | `tau_e` |
|
||||||
|
| `tau_p_FWHM` | `tau_e_FWHM` | | `sigma_p` | `sigma_e` |
|
||||||
|
| `w_0p` | `w_0_e` | | `I_0_p` | `I_0_e` |
|
||||||
|
| `lambda_p` | `lambda_e` | | `ng_p` | `ng_e` |
|
||||||
|
| `R_p` | `R_e` | | `z_0_p` | `z_0_e` |
|
||||||
|
| `alpha_p` | `alpha_e` | | `Tlin_p` | `Tlin_e` |
|
||||||
|
| `n_p` | `n_e` | | `sigma_p2` | `sigma_e2` |
|
||||||
|
| `dndl_p` | `dndl_e` | | `sigma_p20` | `sigma_e20` |
|
||||||
|
| `alpha_2d` | `alpha_2d_e` | | `a_p_0` | `a_e_0` |
|
||||||
|
|
||||||
|
`w_0p` gains the separating underscore it was missing, so the field
|
||||||
|
name finally matches the variable that held it (`w_0_p`) and its
|
||||||
|
siblings `z_0_e` and `I_0_e`. `alpha_2d_e` keeps the `d` for
|
||||||
|
degenerate.
|
||||||
|
|
||||||
|
- **The Electronic mechanism's parameters are renamed `alpha_2e` ->
|
||||||
|
`alpha_2el` and `n_2e` -> `n_2el`**, since their `e` meant
|
||||||
|
*electronic* and would otherwise collide with `_e` for excitation --
|
||||||
|
the pump's degenerate two-photon coefficient would have wanted the
|
||||||
|
name `alpha_2e`, which was taken. `_e` now means excitation and
|
||||||
|
nothing else.
|
||||||
|
|
||||||
|
- `BD_3_level_triplet`, `I_e_func` and `excite_prop` needed no
|
||||||
|
renaming at all: transliterated from the MATLAB, they already used
|
||||||
|
`_e` for the pump and `_p` for the probe, so `n_g_p`, `v_p` and
|
||||||
|
`I_p` inside them were correct all along. With both beams now
|
||||||
|
subscribed to that convention, the whole file reads against the
|
||||||
|
MATLAB without translation.
|
||||||
|
|
||||||
|
- **`last_settings.json` written by an earlier version is now refused
|
||||||
|
rather than misread.** Saved settings carry a `settings_schema`
|
||||||
|
stamp, and a file without the current one is rejected with a message
|
||||||
|
explaining why. This is not housekeeping: because six probe field
|
||||||
|
names are spelled exactly like former pump keys, loading an old file
|
||||||
|
by name alone would have installed the pump's wavelength, index,
|
||||||
|
reflectivity, absorption and dispersion as the *probe's* -- every
|
||||||
|
number plausible, every result wrong. Re-enter the parameters once
|
||||||
|
and they save in the new layout. Any other unrecognised key is still
|
||||||
|
dropped with a note on stderr.
|
||||||
|
|
||||||
|
- Log and panel labels follow their fields on both sides: `n_g_e`,
|
||||||
|
`sigma_e`, `T_lin_e`, `z_0_e`, `I_0_e` for the pump and `n_g_p`,
|
||||||
|
`T_lin_p`, `z_0_p` for the probe, with the beam parameters and
|
||||||
|
material blocks likewise. The GUI's pump calculated-parameters panel
|
||||||
|
also gains a `sigma_e` readout, which it had not displayed before.
|
||||||
|
|
||||||
|
- `T_lin_p` and `T_lin_e` are labelled `T_lin_p (transmission)` and
|
||||||
|
`T_lin_e (transmission)` in both the panel and the log, so the
|
||||||
|
quantity is named and not just abbreviated. The log's value column
|
||||||
|
moved from 25 to 29 to fit them, and the panel's label column from 20
|
||||||
|
to 23 characters -- which also squares up `z_0_p (Rayleigh range)`,
|
||||||
|
`z_0_e (Rayleigh range)` and `I_0_e (peak irradiance)`, all of which
|
||||||
|
had been overrunning the old 20 and pushing their own values out of
|
||||||
|
line.
|
||||||
|
|
||||||
|
- The rename is numerically inert: across 8 mechanism types x 2
|
||||||
|
algorithms x 3 pump-absorption configurations (49 cases, 3275
|
||||||
|
values), `DeltaEoE`, `T`, `Delta_n`, `eta_peak` and `Gamma_peak` are
|
||||||
|
bit-identical to the pre-rename code, and `pyflakes` reports zero
|
||||||
|
warnings before and after.
|
||||||
|
|
||||||
|
- Transmission y-axis tick labels are limited to three significant
|
||||||
|
digits, so "99.75" reads "99.8". The count is a floor rather than a
|
||||||
|
cap: a shallow scan spanning a few hundredths of a percent would
|
||||||
|
round every tick to "100", so digits are added only where that would
|
||||||
|
happen. The deflection axis is unaffected.
|
||||||
|
|
||||||
|
- The reference list in the README and the parameter log follows Optica
|
||||||
|
style: every author listed, initials first, abbreviated journal,
|
||||||
|
volume, full page range, year. Author lists and page ranges were
|
||||||
|
checked against the published papers.
|
||||||
|
- The duplicate supplementary-material citation is dropped, leaving two
|
||||||
|
references.
|
||||||
|
- The parameter log is written as UTF-8. The citations use typographic
|
||||||
|
quotes and an en dash, which the locale's encoding cannot always
|
||||||
|
represent.
|
||||||
|
|
||||||
|
### Fixed
|
||||||
|
|
||||||
|
- The instantaneous (Electronic) response for a sample with both
|
||||||
|
walk-off and pump absorption is evaluated through the scaled
|
||||||
|
complementary error function `erfcx` instead of the form in
|
||||||
|
`BD_Fresnel_func_ni.m`. That form multiplied `exp(sigma_e^2/rho^2 +
|
||||||
|
2 sigma_e u/rho)` by a difference of error functions falling to zero,
|
||||||
|
so the product was lost to cancellation well before it overflowed:
|
||||||
|
at `rho = 0.4336` (l = 0.5 mm) it was already wrong over 8.6% of the
|
||||||
|
delay axis at `sigma_e = 2.5` (alpha_e = 100 cm^-1), **returning
|
||||||
|
exactly 0.0 with no NaN to signal it**, and returned NaN above
|
||||||
|
`sigma_e = 3`. The usable ceiling on `alpha_e` for an Electronic
|
||||||
|
mechanism at that thickness was therefore about 60 cm^-1, not the
|
||||||
|
~120 where NaN first appeared. The rearrangement is algebraic, with
|
||||||
|
every surviving exponent non-positive; it reproduces the original
|
||||||
|
evaluated at 600 decimal digits to 1e-16..3e-13 relative over
|
||||||
|
`sigma_e` = 0.25 to 10 and `u` = -3 to 18, both where the original
|
||||||
|
works and where it does not.
|
||||||
|
- Pump absorption is applied to non-instantaneous mechanisms when the
|
||||||
|
walk-off is exactly zero. Substituting `T1 = (T+T_d) - rho +
|
||||||
|
rho*zeta` shows the `rho != 0` branch to be a depth average over
|
||||||
|
`atten_fac`, whose `rho -> 0` limit is the response at one instant
|
||||||
|
times the *mean* of `atten_fac`; the original used the bare response.
|
||||||
|
The dropped factor is `(1 - exp(-2 sigma_e))/(2 sigma_e)` for linear
|
||||||
|
pump absorption, so the response was previously **independent of
|
||||||
|
`alpha_e` altogether** in this case -- identical at `alpha_e` = 0 and
|
||||||
|
200 cm^-1. It was 1.27x too large at `alpha_e` = 10 cm^-1 and
|
||||||
|
l = 0.5 mm, and 10x at 200 cm^-1. The two branches now agree to nine
|
||||||
|
digits across `rho = 0`. This affects only samples with `ng_p` exactly
|
||||||
|
equal to `ng_e` (for example no dispersion entered at either
|
||||||
|
wavelength) *and* non-zero pump absorption; with `alpha_e = alpha_2d_e
|
||||||
|
= 0` the mean is exactly 1 and results are bit-identical to before.
|
||||||
|
- Pump absorption through the sample depth, `atten_fac`, is computed
|
||||||
|
from the closed-form solution of
|
||||||
|
`dI_e/dz = -alpha_e I_e - alpha_2d_e I_e^2` rather than the two-branch
|
||||||
|
expression carried over from `BD_Fresnel_func_ni.m`. That expression's
|
||||||
|
pump two-photon branch, `sqrt((B1 B2)/sigma_e)`, failed three ways: it
|
||||||
|
did not reduce to its own `sigma_e2 == 0` branch as `alpha_2d_e -> 0`
|
||||||
|
(it decayed at half the correct rate), it divided by zero whenever
|
||||||
|
`alpha_e` was zero, and it took the square root of a negative number
|
||||||
|
whenever `sigma_e20 > sigma_e`. The net effect was that **every run
|
||||||
|
combining a non-zero `alpha_2d_e` with a non-instantaneous mechanism
|
||||||
|
returned NaN at every delay** -- pump two-photon absorption worked
|
||||||
|
only for the Electronic mechanism, which does not use `atten_fac`.
|
||||||
|
Dropping the stray square root recovers that expression as the
|
||||||
|
linearisation of the exact one in `sigma_e20`, which is how the
|
||||||
|
intent was identified. Results for `alpha_2d_e = 0` are bit-identical
|
||||||
|
to before; the new form agrees with numerical integration of the
|
||||||
|
pump propagation equation to 2e-12 relative over `sigma_e` and
|
||||||
|
`sigma_e20` from 0 to 20, including both limits.
|
||||||
|
- A negative `alpha_2d_e` large enough to make the pump diverge inside
|
||||||
|
the sample (two-photon gain, no finite depth average) is now refused
|
||||||
|
with a message naming the largest `|alpha_2d_e|` that works for the
|
||||||
|
current thickness and pump irradiance, rather than silently returning
|
||||||
|
a meaningless attenuation of order 1e12.
|
||||||
|
- `mpmath` is imported only where it is used, in the pump two-photon
|
||||||
|
absorption term. Importing it at module level made an optional
|
||||||
|
dependency fatal at startup, so the program would not run at all
|
||||||
|
without it. If that term is ever reached without mpmath installed,
|
||||||
|
the error now says which package is missing and why.
|
||||||
|
|
||||||
|
## [2.6] - 2026-09-30
|
||||||
|
|
||||||
|
### Added
|
||||||
|
|
||||||
|
- **Simulation** run mode: a second toggle in the Operation mode box,
|
||||||
|
offering **Fitting** and **Simulation**. Fitting is the default and
|
||||||
|
behaves as before.
|
||||||
|
- Simulation mode, for computing a signal without a measurement:
|
||||||
|
- No file is imported. **Import...** and the data column and
|
||||||
|
delimiter fields are disabled.
|
||||||
|
- The delay range is entered as `T_d_min` and `T_d_max` (in `tau_p`)
|
||||||
|
in the Simulation parameters box. In Fitting mode these are taken
|
||||||
|
from the imported scan and the fields are disabled.
|
||||||
|
- Only the calculated curves are plotted, without data markers, and
|
||||||
|
the plot legend reads **Simulated** rather than Fit.
|
||||||
|
- The **Fit** button is relabelled **Simulate**, and is enabled by
|
||||||
|
valid parameters alone rather than by an imported file.
|
||||||
|
- The export holds the calculated signals on their own delay grid,
|
||||||
|
with no data columns to pair them with. The parameter log omits the
|
||||||
|
import path and the data column section.
|
||||||
|
- The mode combines with the measurement mode: Pump probe and
|
||||||
|
Simulation together give a single Transmission panel and a
|
||||||
|
two-column table, as Pump probe does when fitting.
|
||||||
|
- The run mode is saved with the other settings and recorded in the
|
||||||
|
parameter log.
|
||||||
|
|
||||||
|
### Changed
|
||||||
|
|
||||||
|
- The **Mode** box is renamed **Operation mode** and moved to the top of
|
||||||
|
the parameter panel, above Data columns. The parameter log and status
|
||||||
|
messages use the new name, and the log records both modes on one line.
|
||||||
|
- Changing run mode discards the current result, which described the
|
||||||
|
other mode's delay range or a measurement the new mode does not show.
|
||||||
|
Switching to Simulation sets the imported scan aside and switching
|
||||||
|
back reloads it. The run mode cannot be changed while a fit runs.
|
||||||
|
- `inputs_valid` takes a `require_data` argument, so Simulation can
|
||||||
|
enable its action button without an imported file. Fitting is
|
||||||
|
unaffected.
|
||||||
|
|
||||||
## [2.5] - 2026-09-21
|
## [2.5] - 2026-09-21
|
||||||
|
|
||||||
@@ -38,6 +323,7 @@ The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
|||||||
mode's column requirements. A file the new mode cannot use is cleared
|
mode's column requirements. A file the new mode cannot use is cleared
|
||||||
with an explanation, and loaded again on switching back. The mode
|
with an explanation, and loaded again on switching back. The mode
|
||||||
cannot be changed while a fit runs.
|
cannot be changed while a fit runs.
|
||||||
|
- The source files carry the GPLv3 notice.
|
||||||
|
|
||||||
### Fixed
|
### Fixed
|
||||||
|
|
||||||
@@ -61,10 +347,6 @@ The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
|
|||||||
is hidden when it collides with its neighbour. A rounding error let some
|
is hidden when it collides with its neighbour. A rounding error let some
|
||||||
such labels through.
|
such labels through.
|
||||||
|
|
||||||
### Changed
|
|
||||||
|
|
||||||
- The source files carry the GPLv3 notice.
|
|
||||||
|
|
||||||
## [2.4] - 2026-09-21
|
## [2.4] - 2026-09-21
|
||||||
|
|
||||||
First release recorded in this changelog. Earlier history is not documented
|
First release recorded in this changelog. Earlier history is not documented
|
||||||
|
|||||||
@@ -15,6 +15,10 @@ Two measurement modes are supported. **Beam deflection** fits both signals.
|
|||||||
there is no deflection: it fits the transmission alone, and needs only delay
|
there is no deflection: it fits the transmission alone, and needs only delay
|
||||||
and transmission data.
|
and transmission data.
|
||||||
|
|
||||||
|
The program also runs without a measurement. In **Simulation** mode nothing is
|
||||||
|
imported: the signal is computed from the parameters alone, over a delay range
|
||||||
|
entered by hand, and only the calculated curves are plotted and exported.
|
||||||
|
|
||||||

|

|
||||||
|
|
||||||
## Features
|
## Features
|
||||||
@@ -27,10 +31,17 @@ and transmission data.
|
|||||||
parameter `rho`.
|
parameter `rho`.
|
||||||
- Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁,
|
- Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁,
|
||||||
T₂) solved through the sample depth for a range of radial irradiances.
|
T₂) solved through the sample depth for a range of radial irradiances.
|
||||||
- Side-by-side transmission and deflection plots with imported data overlaid.
|
- Side-by-side transmission and deflection plots, with imported data overlaid
|
||||||
|
when there is any.
|
||||||
- Beam deflection and pump probe measurement modes. Pump probe reads a
|
- Beam deflection and pump probe measurement modes. Pump probe reads a
|
||||||
two-column delay/transmission scan, fixes the probe on the pump axis, and
|
two-column delay/transmission scan, fixes the probe on the pump axis, and
|
||||||
offers only the mechanisms that can change the transmission.
|
offers only the mechanisms that can change the transmission.
|
||||||
|
- Fitting and simulation run modes. Simulation computes the signal with no
|
||||||
|
data imported, over a delay range entered in the panel.
|
||||||
|
- Two interchangeable algorithms. Fresnel propagation carries the exit field to
|
||||||
|
the detector by FFT; the semi-analytical method uses closed-form detector
|
||||||
|
power expressions instead, needing no spatial grid and running about 32x
|
||||||
|
faster, at the cost of holding only to first order in the nonlinear response.
|
||||||
- Optional diagnostic figures showing each mechanism's response function before
|
- Optional diagnostic figures showing each mechanism's response function before
|
||||||
and after convolution, plus the ESA populations and beam transmissions.
|
and after convolution, plus the ESA populations and beam transmissions.
|
||||||
- Export of the data/fit comparison, a full parameter log, and figures at
|
- Export of the data/fit comparison, a full parameter log, and figures at
|
||||||
@@ -62,18 +73,31 @@ python bd_fresnel_gui.py
|
|||||||
The window opens with the parameter panel on the left and three tabs on the
|
The window opens with the parameter panel on the left and three tabs on the
|
||||||
right: **Fitting**, **Diagnostics**, and **Parameter log**.
|
right: **Fitting**, **Diagnostics**, and **Parameter log**.
|
||||||
|
|
||||||
A typical session:
|
Fitting a measured scan:
|
||||||
|
|
||||||
1. Set the **Data columns** to match your file, and the delimiter.
|
1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**,
|
||||||
2. Choose the **Mode**: Beam deflection or Pump probe.
|
leave the second toggle on **Fitting**, and pick an algorithm on the third:
|
||||||
|
**Fresnel propagation** or the faster **Semi-analytical**.
|
||||||
|
2. Set the **Data columns** to match your file, and the delimiter.
|
||||||
3. Press **Import…** and choose a scan. The plots show the measured data.
|
3. Press **Import…** and choose a scan. The plots show the measured data.
|
||||||
4. Fill in the beam, material and geometry parameters, and configure one or
|
4. Fill in the beam, material and geometry parameters, and configure one or
|
||||||
more mechanisms with the **Params…** buttons.
|
more mechanisms with the **Params…** buttons.
|
||||||
5. Press **Fit** to run the simulation and overlay it on the data.
|
5. Press **Fit** to run the simulation and overlay it on the data.
|
||||||
6. Press **Export…** to write the results.
|
6. Press **Export…** to write the results.
|
||||||
|
|
||||||
**Fit** stays disabled until a file is imported, and **Export** until a fit has
|
Simulating without a measurement:
|
||||||
completed.
|
|
||||||
|
1. Under **Operation mode**, choose **Simulation**. **Import…** and the data
|
||||||
|
column fields are disabled, and **Fit** becomes **Simulate**. The algorithm
|
||||||
|
toggle works the same way as in Fitting mode.
|
||||||
|
2. Set `T_d_min` and `T_d_max` in **Simulation parameters** to the delay range
|
||||||
|
to compute over. In Fitting mode these come from the imported file, so they
|
||||||
|
are editable only here.
|
||||||
|
3. Fill in the parameters and mechanisms as above.
|
||||||
|
4. Press **Simulate**, then **Export…**.
|
||||||
|
|
||||||
|
**Fit** stays disabled until a file is imported; **Simulate** needs only valid
|
||||||
|
parameters. **Export** stays disabled until a fit or simulation has completed.
|
||||||
|
|
||||||
Changing the mode, a column number or the delimiter re-reads the imported file.
|
Changing the mode, a column number or the delimiter re-reads the imported file.
|
||||||
Any fit is discarded, since it belonged to the previous settings. If the file
|
Any fit is discarded, since it belonged to the previous settings. If the file
|
||||||
@@ -90,11 +114,11 @@ deflection needs three columns and pump probe two; which ones is set in the
|
|||||||
**Data columns** box, so extra columns can be present and ignored. Each
|
**Data columns** box, so extra columns can be present and ignored. Each
|
||||||
quantity must come from a different column.
|
quantity must come from a different column.
|
||||||
|
|
||||||
| Quantity | Units | Default column | Needed in |
|
| Quantity | Units | Default column | Needed in |
|
||||||
| --- | --- | --- | --- |
|
|----------|------------------------------|----------------|----------------------|
|
||||||
| `τ_d` | fs | 1 | both modes |
|
| `τ_d` | fs | 1 | both modes |
|
||||||
| `ΔE/E` | fractional | 2 | Beam deflection only |
|
| `ΔE/E` | fractional | 2 | Beam deflection only |
|
||||||
| `T` | fractional (1.0 = no change) | 3 | both modes |
|
| `T` | fractional (1.0 = no change) | 3 | both modes |
|
||||||
|
|
||||||
The delimiter field takes a single character, `\t` for a tab, or is left blank
|
The delimiter field takes a single character, `\t` for a tab, or is left blank
|
||||||
to split on any run of whitespace.
|
to split on any run of whitespace.
|
||||||
@@ -103,88 +127,147 @@ to split on any run of whitespace.
|
|||||||
|
|
||||||
### Data columns (1-indexed)
|
### Data columns (1-indexed)
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|-------------------|---------|---------------------------------------|
|
|-------------------|---------|---------------------------------|
|
||||||
| `tau_d column` | `1` | Delay column (fs) |
|
| `tau_d column` | `1` | Delay column (fs) |
|
||||||
| `T column` | `3` | Transmission data column |
|
| `T column` | `3` | Transmission data column |
|
||||||
| `DeltaEoE column` | `2` | Deflection data column |
|
| `DeltaEoE column` | `2` | Deflection data column |
|
||||||
| `Delimiter` | `,` | Data column delimiter character |
|
| `Delimiter` | `,` | Data column delimiter character |
|
||||||
|
|
||||||
### Mode
|
### Operation mode
|
||||||
|
|
||||||
| Option | Effect |
|
Three independent toggles. Any combination is valid.
|
||||||
|-------------------|-------------------------------------------------|
|
|
||||||
| `Beam deflection` | Transmission and deflection, offset probe |
|
| Toggle | Option | Effect |
|
||||||
| `Pump probe` | Transmission only, centered probe |
|
|-------------|-----------------------|--------------------------------------------------|
|
||||||
|
| Measurement | `Beam deflection` | Transmission and deflection, offset probe |
|
||||||
|
| | `Pump probe` | Transmission only, centered probe |
|
||||||
|
| Run | `Fitting` | Compare the calculation against an imported scan |
|
||||||
|
| | `Simulation` | Calculate without a scan, over an entered range |
|
||||||
|
| Algorithm | `Fresnel propagation` | Propagate the exit field to the detector by FFT |
|
||||||
|
| | `Semi-analytical` | Closed-form detector power, no spatial grid |
|
||||||
|
|
||||||
|
#### Algorithm
|
||||||
|
|
||||||
|
**Fresnel propagation** is the original method. The field at the exit face is
|
||||||
|
built on an (x, y) grid, propagated to the detector by FFT, and integrated over
|
||||||
|
the detector halves to get the power difference and total at each instant.
|
||||||
|
|
||||||
|
**Semi-analytical** skips the propagation. It evaluates closed-form expressions
|
||||||
|
for the detector power difference `dP` and total `P`, already integrated over
|
||||||
|
the detector plane, then integrates each over time at every delay to get the
|
||||||
|
energy difference `dE` and total `E`. The deflection is `dE/E` and the
|
||||||
|
transmission is `E` normalised. With no spatial grid to size, `X_num` and
|
||||||
|
`X_max` are greyed out; every other parameter, `Delta_n` included, is
|
||||||
|
unaffected. On the four-layer example it runs in 0.11 s against 3.65 s, about
|
||||||
|
**32x faster**.
|
||||||
|
|
||||||
|
The trade-off is that `dP` is **first order in the nonlinear response**, where
|
||||||
|
the Fresnel path keeps every order. The two therefore agree only while the
|
||||||
|
phase is small, which the `eta (peak)` line of the parameter log reports:
|
||||||
|
|
||||||
|
| `eta (peak)` | Peak of `DeltaEoE` displaced by |
|
||||||
|
|--------------|---------------------------------|
|
||||||
|
| 0.14 rad | 0.0003 tau_e |
|
||||||
|
| 1.41 rad | 0.0035 tau_e |
|
||||||
|
| 5.64 rad | 0.077 tau_e |
|
||||||
|
| 14.1 rad | 0.36 tau_e |
|
||||||
|
|
||||||
|
Below roughly 1 rad the two are interchangeable, and the four-layer example sits
|
||||||
|
at 0.049 rad with a correlation of 1.000000 and amplitudes within 0.5%. Above a
|
||||||
|
few rad the semi-analytical curve shifts noticeably and is no longer a
|
||||||
|
substitute. Sample thickness, walk-off and pump absorption do not themselves
|
||||||
|
affect the agreement once `eta (peak)` is held fixed.
|
||||||
|
|
||||||
|
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
|
||||||
|
path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`
|
||||||
|
is the pump amplitude profile, while the semi-analytical form uses the on-axis
|
||||||
|
`exp(-2 x_0^2)`.
|
||||||
|
|
||||||
|
One coefficient in `dP`'s absorptive term, `SA_ABSORPTIVE_FACTOR`, is at present
|
||||||
|
fitted against the Fresnel path rather than derived. It is isolated in a single
|
||||||
|
function in `bd_fresnel_core.py`, with the measurements behind it recorded
|
||||||
|
there.
|
||||||
|
|
||||||
|
The transmission needs a reference delay, taken from before the pump arrives.
|
||||||
|
In **Fitting** mode it is the first delay point of the imported scan; in
|
||||||
|
**Simulation** mode it is `min(-3 rho, -3)` tau_e, which follows the walk-off
|
||||||
|
when that is the larger scale and is three pulse widths otherwise, so a thin
|
||||||
|
sample still normalises away from the peak.
|
||||||
|
|
||||||
### Simulation parameters
|
### Simulation parameters
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|---------|---------------------------------------|
|
|-----------|---------|-------------------------------------------------|
|
||||||
| `X_num` | `50` | Number of spatial points |
|
| `X_num` | `50` | Number of spatial points, Fresnel only |
|
||||||
| `X_max` | `5.0` | Range of spatial sampling (w_0) |
|
| `X_max` | `5.0` | Range of spatial sampling (w_0_p), Fresnel only |
|
||||||
| `T_num` | `100` | Number of temporal points |
|
| `T_num` | `100` | Number of temporal points |
|
||||||
| `T_max` | `5.0` | Range of temporal sampling (tau_p) |
|
| `T_max` | `5.0` | Range of temporal sampling (tau_e) |
|
||||||
| `T_d_num` | `150` | Number of delay points over range |
|
| `T_d_num` | `150` | Number of delay points over range |
|
||||||
|
| `T_d_min` | `-5.0` | Delay range start (tau_e), Simulation only |
|
||||||
|
| `T_d_max` | `5.0` | Delay range end (tau_e), Simulation only |
|
||||||
|
|
||||||
|
`X_num` and `X_max` size the spatial grid the Fresnel method propagates, so the
|
||||||
|
semi-analytical method greys them out.
|
||||||
|
|
||||||
### Excitation beam parameters
|
### Excitation beam parameters
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|---------|---------------------------------------|
|
|--------------|---------|----------------------------------|
|
||||||
| `E_p` | `1.36` | Excitation pulse energy (uJ) |
|
| `E_e` | `1.36` | Excitation pulse energy (uJ) |
|
||||||
| `tau_p_FWHM` | `55.0` | Excitation pulse duration (fs) |
|
| `tau_e_FWHM` | `55.0` | Excitation pulse duration (fs) |
|
||||||
| `w_0p` | `246.0` | Excitation beam waist (um) |
|
| `w_0_e` | `246.0` | Excitation beam waist (um) |
|
||||||
| `lambda_p` | `800.0` | Excitation pulse wavelength (nm) |
|
| `lambda_e` | `800.0` | Excitation pulse wavelength (nm) |
|
||||||
|
|
||||||
### Probe beam parameters
|
### Probe beam parameters
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|---------|---------------------------------------|
|
|--------------|---------|-----------------------------|
|
||||||
| `tau_FWHM` | `60.0` | Probe pulse duration (fs) |
|
| `tau_p_FWHM` | `60.0` | Probe pulse duration (fs) |
|
||||||
| `w_0` | `43.0` | Probe beam waist (um) |
|
| `w_0_p` | `43.0` | Probe beam waist (um) |
|
||||||
| `lambda` | `650.0` | Probe pulse wavelength (nm) |
|
| `lambda_p` | `650.0` | Probe pulse wavelength (nm) |
|
||||||
|
|
||||||
### Material parameters at excitation wavelength
|
### Material parameters at excitation wavelength
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|-------------|-----------------------------------|
|
|--------------|-------------|--------------------------------|
|
||||||
| `R_p` | `0.0` | Reflectivity |
|
| `R_e` | `0.0` | Reflectivity |
|
||||||
| `alpha_p` | `0.0` | Linear absorption (cm^-1) |
|
| `alpha_e` | `0.0` | Linear absorption (cm^-1) |
|
||||||
| `n_p` | `1.4533` | Linear index |
|
| `n_e` | `1.4533` | Linear index |
|
||||||
| `dndl_p` | `-0.017284` | First order dispersion (um^-1) |
|
| `dndl_e` | `-0.017284` | First order dispersion (um^-1) |
|
||||||
| `alpha_2d` | `0.0` | 2 photon absorption (e-11 m/W) |
|
| `alpha_2d_e` | `0.0` | 2 photon absorption (e-11 m/W) |
|
||||||
|
|
||||||
### Material parameters at probe wavelength
|
### Material parameters at probe wavelength
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|-------------|-----------------------------------|
|
|-----------|-------------|--------------------------------|
|
||||||
| `R` | `0.0` | Reflectivity |
|
| `R_p` | `0.0` | Reflectivity |
|
||||||
| `alpha` | `0.0` | Linear absorption (cm^-1) |
|
| `alpha_p` | `0.0` | Linear absorption (cm^-1) |
|
||||||
| `n` | `1.4565` | Linear index |
|
| `n_p` | `1.4565` | Linear index |
|
||||||
| `dndl` | `-0.027158` | First order dispersion (um^-1) |
|
| `dndl_p` | `-0.027158` | First order dispersion (um^-1) |
|
||||||
|
|
||||||
### Measurement parameters
|
### Measurement parameters
|
||||||
|
|
||||||
| Variable | Default | Column contents |
|
| Variable | Default | Column contents |
|
||||||
|----------------|-------------|-----------------------------------|
|
|----------|---------|-------------------------------|
|
||||||
| `l` | `1.0` | Sample thickness (mm) |
|
| `l` | `1.0` | Sample thickness (mm) |
|
||||||
| `d` | `15.0` | Distance to detector (cm) |
|
| `d` | `15.0` | Distance to detector (cm) |
|
||||||
| `shift` | `0.0` | Temporal shift (fs) |
|
| `shift` | `0.0` | Temporal shift (fs) |
|
||||||
| `x_0` | `0.5` | Displacement of probe (w_0p) |
|
| `x_0` | `0.5` | Displacement of probe (w_0_e) |
|
||||||
|
|
||||||
## Mechanisms
|
## Mechanisms
|
||||||
|
|
||||||
| Mechanism | Parameters |
|
| Mechanism | Parameters |
|
||||||
| --- | --- |
|
|--------------------------------|------------|
|
||||||
| Electronic (both) | 2 |
|
| Electronic (both) | 2 |
|
||||||
| Collisional (NLR) | 3 |
|
| Collisional (NLR) | 3 |
|
||||||
| Librational (NLR) | 4 |
|
| Librational (NLR) | 4 |
|
||||||
| Reorientational (NLR) | 3 |
|
| Reorientational (NLR) | 3 |
|
||||||
| Vibrational (NLR) | 3 |
|
| Vibrational (NLR) | 3 |
|
||||||
| ESA – 3 level + triplet (both) | 10 |
|
| ESA – 3 level + triplet (both) | 10 |
|
||||||
| Exponential rise/decay (NLA) | 3 |
|
| Exponential rise/decay (NLA) | 3 |
|
||||||
| Exponential rise/decay (NLR) | 3 |
|
| Exponential rise/decay (NLR) | 3 |
|
||||||
| Exponential rise/decay (both) | 4 |
|
| Exponential rise/decay (both) | 4 |
|
||||||
|
|
||||||
`NLR` denotes a purely refractive response, `NLA` a purely absorptive one, and
|
`NLR` denotes a purely refractive response, `NLA` a purely absorptive one, and
|
||||||
`both` a mechanism carrying each.
|
`both` a mechanism carrying each.
|
||||||
@@ -199,43 +282,46 @@ is still empty.
|
|||||||
|
|
||||||
Exporting to `<name>_fit.txt` also writes, in the same directory:
|
Exporting to `<name>_fit.txt` also writes, in the same directory:
|
||||||
|
|
||||||
| File | Contents |
|
| File | Contents |
|
||||||
| --- | --- |
|
|----------------------------------------|------------------------------------------------------------------------------------------------------------------------------|
|
||||||
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only |
|
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
|
||||||
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
|
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
|
||||||
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
|
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
|
||||||
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
|
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
|
||||||
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
|
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
|
||||||
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
|
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
|
||||||
|
|
||||||
The last two appear only when *Show diagnostic plots during Fit* is ticked.
|
The last two appear only when *Show diagnostic plots during Fit* is ticked.
|
||||||
|
|
||||||
The log records enough to reproduce a run: data columns and delimiter, the
|
In Simulation mode the export is named after the file you choose rather than an
|
||||||
mode, the simulation grid, every beam, material and geometry value, each
|
imported scan, and the table holds the calculated signals on their own delay
|
||||||
mechanism with its parameters, and the derived quantities (`n_g`, `T_lin`,
|
grid, with no data columns to pair them with.
|
||||||
`z_0`, `I_0`, `rho`).
|
|
||||||
|
The log records enough to reproduce a run: both modes, the data columns and
|
||||||
|
delimiter, the simulation grid including the delay range, every beam, material
|
||||||
|
and geometry value, each mechanism with its parameters, and the derived
|
||||||
|
quantities (`n_g`, `T_lin`, `z_0`, `I_0`, `rho`). In Simulation mode the import
|
||||||
|
path and data column sections are omitted, having nothing to describe.
|
||||||
|
|
||||||
## Files
|
## Files
|
||||||
|
|
||||||
| File | Role |
|
| File | Role |
|
||||||
| --- | --- |
|
|------------------------|--------------------------------------------------------------------------------------------------------------------------|
|
||||||
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
|
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
|
||||||
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
|
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
|
||||||
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
|
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
|
||||||
|
|
||||||
## References
|
## References
|
||||||
|
|
||||||
Please cite the following when using results from this program.
|
Please cite the following when using results from this program.
|
||||||
|
|
||||||
1. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
|
1. M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, T. R. Ensley,
|
||||||
dependence of the nonlinear optical response of carbon disulfide."
|
D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and
|
||||||
*Optica* **1**(6): 436.
|
E. W. Van Stryland, “Temporal, spectral, and polarization dependence of the
|
||||||
2. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
|
nonlinear optical response of carbon disulfide,” Optica **1**, 436–445 (2014).
|
||||||
dependence of the nonlinear optical response of carbon disulfide:
|
2. M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and E. W. Van Stryland,
|
||||||
supplementary material." *Optica* **1**(6): 436.
|
“Beam deflection measurement of time and polarization resolved ultrafast
|
||||||
3. Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and
|
nonlinear refraction,” Opt. Lett. **38**, 3518–3521 (2013).
|
||||||
polarization resolved ultrafast nonlinear refraction." *Opt. Lett.*
|
|
||||||
**38**(18): 3518–3521.
|
|
||||||
|
|
||||||
## License
|
## License
|
||||||
|
|
||||||
|
|||||||
+597
-166
File diff suppressed because it is too large
Load Diff
+496
-179
File diff suppressed because it is too large
Load Diff
Binary file not shown.
|
Before Width: | Height: | Size: 124 KiB After Width: | Height: | Size: 355 KiB |
@@ -0,0 +1,165 @@
|
|||||||
|
{
|
||||||
|
"E_e": 1.0,
|
||||||
|
"tau_e_FWHM": 45.0,
|
||||||
|
"w_0_e": 142.83,
|
||||||
|
"lambda_e": 800.0,
|
||||||
|
"tau_p_FWHM": 100.0,
|
||||||
|
"w_0_p": 22.253,
|
||||||
|
"lambda_p": 650.0,
|
||||||
|
"R_e": 0.0,
|
||||||
|
"alpha_e": 0.0,
|
||||||
|
"n_e": 1.4533,
|
||||||
|
"dndl_e": -0.017284,
|
||||||
|
"alpha_2d_e": 0.0,
|
||||||
|
"R_p": 0.0,
|
||||||
|
"alpha_p": 0.0,
|
||||||
|
"n_p": 1.4565,
|
||||||
|
"dndl_p": -0.027158,
|
||||||
|
"l": 1.72e-06,
|
||||||
|
"d": 15.0,
|
||||||
|
"shift": 70.0,
|
||||||
|
"x_0": 0.5,
|
||||||
|
"tau_e": 27.025254197695123,
|
||||||
|
"tau_p": 60.05612043932249,
|
||||||
|
"sigma_e": 0.0,
|
||||||
|
"I_0_e": 651473158047437.0,
|
||||||
|
"ng_e": 1.4671272,
|
||||||
|
"ng_p": 1.4741526999999999,
|
||||||
|
"rho": 0.8671350632529666,
|
||||||
|
"z_0_p": 0.0023933909907098232,
|
||||||
|
"z_0_e": 0.0801122184130848,
|
||||||
|
"Tlin_p": 1.0,
|
||||||
|
"Tlin_e": 1.0,
|
||||||
|
"X_max": 5.0,
|
||||||
|
"X_num": 50,
|
||||||
|
"T_min": -5.0,
|
||||||
|
"T_max": 5.0,
|
||||||
|
"T_num": 100,
|
||||||
|
"T_d_min": -9.579367435592124,
|
||||||
|
"T_d_max": 39.791355601447556,
|
||||||
|
"T_d_num": 150,
|
||||||
|
"n_mech": 7,
|
||||||
|
"mech": [
|
||||||
|
{
|
||||||
|
"name": "Exponential rise/decay (both)",
|
||||||
|
"param": [
|
||||||
|
3600.0,
|
||||||
|
-200000.0,
|
||||||
|
1.0,
|
||||||
|
170.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "Exponential rise/decay (both)",
|
||||||
|
"param": [
|
||||||
|
15000.0,
|
||||||
|
-500000.0,
|
||||||
|
0.1,
|
||||||
|
10000.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "None (both)",
|
||||||
|
"param": [
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "None (both)",
|
||||||
|
"param": [
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "None (both)",
|
||||||
|
"param": [
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "None (both)",
|
||||||
|
"param": [
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"name": "None (both)",
|
||||||
|
"param": [
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0,
|
||||||
|
0.0
|
||||||
|
]
|
||||||
|
}
|
||||||
|
],
|
||||||
|
"col_tau_d": 1,
|
||||||
|
"col_DeltaEoE": 2,
|
||||||
|
"col_T": 3,
|
||||||
|
"delimiter": ",",
|
||||||
|
"diagnostics": true,
|
||||||
|
"data_imported": true,
|
||||||
|
"data_fit": true,
|
||||||
|
"mode": "beam_deflection",
|
||||||
|
"run_mode": "fitting",
|
||||||
|
"algorithm": "semi_analytical",
|
||||||
|
"x_0_beam_deflection": 0.5,
|
||||||
|
"mech_beam_deflection": [],
|
||||||
|
"filename": "20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
|
||||||
|
"pathname": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/",
|
||||||
|
"import_filepath": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
|
||||||
|
"settings_schema": 3
|
||||||
|
}
|
||||||
@@ -9,4 +9,9 @@
|
|||||||
numpy>=2.0
|
numpy>=2.0
|
||||||
scipy>=1.6
|
scipy>=1.6
|
||||||
matplotlib>=3.4
|
matplotlib>=3.4
|
||||||
|
|
||||||
|
# Optional. Only needed for the pump two-photon absorption term
|
||||||
|
# (alpha_2d_e != 0), which uses the polylogarithm Li_3/2. The core
|
||||||
|
# imports it lazily, so the program runs without it until that term is
|
||||||
|
# used, and then says so.
|
||||||
mpmath>=1.2
|
mpmath>=1.2
|
||||||
|
|||||||
Reference in New Issue