+50
View File
@@ -0,0 +1,50 @@
# Changelog
All notable changes to Z-Scan Beam Simulation are documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
## [Unreleased]
## [1.5] - 2026-09-23
### Added
- **Operation Mode** box, above Data File: a two-button toggle selecting
**Fitting** or **Simulation**. Fitting is the default and behaves as
before.
- Simulation mode, which calculates and displays the signals with no
measured data:
- The Data File, Data Columns and Processing Flags inputs are
disabled, as are Import and Refine Fit, and the Referenced /
Normalized tab. **Max iterations** is disabled too, since it caps
Refine Fit. **Show CA (else OA/CA)** stays available, since it
selects which curve the right-hand plot shows and both are
simulated.
- Run Simulation is available without importing anything.
- The z range is set by a new **z range (sim.)** field, in Rayleigh
ranges either side of focus (default 15). It is disabled in Fitting
mode, where the range still comes from the data.
- The Fit Results plots show the simulated curves alone, with 5% of
the vertical span left clear above and below them, and the log
reports the simulated peak-to-valley values in place of the
data-versus-fit comparison and chi-squares.
- Export asks where to write the files, since there is no imported
file to name them from, and writes the simulated curves, the log and
the plot images.
- The selected mode and the simulation z range are saved with the other
settings.
### Changed
- **Show CA (else OA/CA)** now repeats the run, in either mode, so the
right-hand plot follows the tick immediately instead of waiting for
the next manual run. Nothing happens if no run has been made yet.
- Changing the operation mode clears the results on screen, which were
produced under the other mode. An imported scan is kept, so returning
to Fitting does not require importing again.
## [1.4] - 2026-09-23
First release recorded in this changelog. Earlier history is not documented
here.
+123 -26
View File
@@ -23,6 +23,9 @@ FM4I.6](https://doi.org/10.1364/FIO.2012.FM4I.6)) — see
## Features
- **Two operation modes.** *Fitting* imports a measured scan and compares the
simulation with it. *Simulation* calculates and displays the signals with no
data at all, over a z range you specify.
- **Load raw scan files** with configurable 1-indexed column mapping, so data
from different acquisition setups can be read without editing the file. A
header row is skipped. Leaving the delimiter blank splits on whitespace,
@@ -90,30 +93,58 @@ python zscan_gui.py
## Usage
1. **Browse** to a scan file and set the column numbers for position, CA, OA and
1. **Choose the Operation Mode** — *Fitting* (the default) or *Simulation*.
The steps below describe Fitting; for Simulation see
[Simulation mode](#simulation-mode).
2. **Browse** to a scan file and set the column numbers for position, CA, OA and
the reference channel. Columns are 1-indexed, matching how they are usually
numbered in acquisition software.
2. **Import.** The Referenced / Normalized tab shows the raw and corrected
3. **Import.** The Referenced / Normalized tab shows the raw and corrected
traces with the baseline fit drawn over them, so you can confirm the columns
and flags are right before simulating. Changing a column or a processing flag
re-reads the file and redraws immediately.
3. **Enter the measurement parameters** — pulse energy, wavelength, beam waist,
4. **Enter the measurement parameters** — pulse energy, wavelength, beam waist,
pulse width, sample thickness and refractive index, aperture transmittance.
4. **Run Simulation** to overlay the simulated curves on the data.
5. **Refine Fit** — tick the coefficients to vary and let the optimizer adjust
5. **Run Simulation** to overlay the simulated curves on the data.
6. **Refine Fit** — tick the coefficients to vary and let the optimizer adjust
them. It runs in the background with a live iteration count.
6. **Export** to write the fit data, log and images next to the input file.
7. **Export** to write the fit data, log and images next to the input file.
### Simulation mode
Selecting **Simulation** calculates the signals without any measurement. Every
input that describes a data file is switched off — the Data File, Data Columns
and Processing Flags boxes, along with **Import**, **Refine Fit**, **Max
iterations** and the Referenced / Normalized tab — and **Run Simulation**
becomes available with nothing imported.
The scan's extent is not measured but stated: **z range (sim.)** sets the
half-width in Rayleigh ranges *z₀* either side of focus (default 15). The
Fit Results panels show the simulated curves alone, padded by 5% above and
below, and the log reports the simulated peak-to-valley values in place of the
data-versus-fit comparison and chi-squares.
**Show CA (else OA/CA)** stays available, since it selects which curve the
right-hand panel draws and both are simulated. Ticking it repeats the run so
the plot follows immediately.
Anything already imported is kept while you work in Simulation, so switching
back to Fitting does not mean importing again. Switching either way clears the
results on screen, which belonged to the other mode.
### Exported files
Written alongside the input file, with an optional extra label in the name:
Written alongside the input file, with an optional extra label in the name. In
Simulation mode there is no input file to name them from, so **Export** asks
where to write; the CSV then holds the simulated curves and no reference figure
is produced:
| File | Contents |
|---|---|
| `<name>_fit.<ext>` | CSV of position, data and fit for the OA, CA and CA/OA curves |
| `<name>_fit.<ext>` | CSV of position, data and fit for the OA, CA and CA/OA curves; in Simulation, position and the simulated OA, CA and CA/OA |
| `<name>_fit_log.txt` | Every parameter, fit-quality metric and output path |
| `<name>_fit.jpg` / `.svg` | Fit figure, raster and vector |
| `<name>_fit_ref.jpg` / `.svg` | Referenced/normalized figure |
| `<name>_fit_ref.jpg` / `.svg` | Referenced/normalized figure (Fitting only) |
## Project structure
@@ -141,33 +172,99 @@ The program is split so the physics can be used without the interface:
## Parameters
<details>
<summary>Full parameter list</summary>
### Operation mode
**Data columns** — `z_col`, `CA_col`, `OA_col`, `REF_col`, `FREQ_col` (1-indexed)
| Option | Effect |
|--------------|-----------------------------------------------------------------|
| `Fitting` | Default. Imports a scan and compares the simulation with it. |
| `Simulation` | No data. The calculated signals are shown alone. |
**Processing flags** — `use_ref`, `use_freq`, `flip_z`, `do_norm_OA`,
`do_norm_CA`, and per-channel sign flips for the raw and displayed traces
### Data columns (1-indexed)
**Nonlinear coefficients** — `n_2` (m²/W), `n_3` (m⁴/W²), `n_4` (m⁶/W³),
`alpha_2` (m/W), `alpha_3` (m³/W²), `alpha_4` (m⁵/W³)
| Variable | Default | Column contents |
|------------|---------|---------------------------------------|
| `z_col` | `0` | Sample position *z* (mm) |
| `CA_col` | `1` | Closed-aperture detector signal (V) |
| `FREQ_col` | `3` | Frequency / shot-index channel |
| `OA_col` | `4` | Open-aperture detector signal (V) |
| `REF_col` | `7` | Reference detector signal (V) |
| `FREQ_col` | `9` | Lock-in frequency column (V) |
**z-position offsets** — `Delta_z_OA`, `Delta_z_CA`, `Delta_z_OACA` (mm), to
align each measured curve with the simulated focus
### Processing flags
**Sample** — `n` (linear index), `L` (thickness), `T_lin` (linear transmittance)
| Parameter | Meaning |
|--------------------------------------|-------------------------------------------------------------|
| `use_ref` | Apply the reference-channel correction |
| `use_freq` | Appliy the frequency-channel correction |
| `flip_z` | Reverses the direction of the z axi |
| `do_norm_OA`, `do_norm_CA` | Fit and divide out the linear wing baseline |
| `flip_OA`, `flip_CA`, `flip_REF` | Invert a raw channel about its median |
| `flip_OA_disp`, `flip_CA_disp` | Invert the normalized traces for display/fitting |
| `show_CA` | Plot CA in the right panel; if `False`, plot CA/OA instead |
**Laser** — `E` (pulse energy), `lambda_`, `w_0` (waist), `tau_FWHM`, `M2`
### Nonlinear coefficients
**Measurement** — `S` (aperture transmittance), `d` (focus-to-aperture distance)
| Parameter | Meaning | Units | Log units |
|-----------|----------------------------------------|----------|------------|
| `n_2` | 3rd-order nonlinear refractive index | m²/W | cm²/GW |
| `n_3` | 5th-order nonlinear refractive index | m⁴/W² | cm⁴/GW² |
| `n_4` | 7th-order nonlinear refractive index | m⁶/W³ | cm⁶/GW³ |
| `alpha_2` | Two-photon absorption coefficient | m/W | cm/GW |
| `alpha_3` | Three-photon absorption coefficient | m³/W² | cm³/GW² |
| `alpha_4` | Four-photon absorption coefficient | m⁵/W³ | cm⁵/GW³ |
**Error estimates** — `E_err`, `w_err`, `tau_err`, as fractions, propagated into
the reported uncertainty
### z-position offsets
**Simulation grid** — `z_points`, `r_points`, `r_max`, `t_points`, `t_max`,
`ra_points`, `endpts_percent`, `max_iterations`
`Delta_z_OA`, `Delta_z_CA`, `Delta_z_OACA` (mm) shift the OA, CA, and CA/OA
z-axes independently so that measured and simulated curves line up when the two
detector arms are not perfectly co-registered.
</details>
### Sample parameters
| Parameter | Meaning | Units |
|-------------|---------------------------------------------|-------|
| `n` | Linear refractive index | — |
| `L` | Sample thickness | m |
| `T_lin` | Linear transmittance | — |
### Laser parameters
| Parameter | Meaning | Units |
|-------------|---------------------------------------------|-------|
| `E` | Pulse energy | J |
| `lambda` | Wavelength | m |
| `w_0` | Beam waist, HW1/e² of irradiance | m |
| `tau_FWHM` | Pulse duration, FWHM of irradiance | s |
| `M2` | Beam quality parameter M² | — |
### Measurement parameters
| Parameter | Meaning | Units |
|-------------|---------------------------------------------|-------|
| `S` | Linear transmission of the aperture | — |
| `d` | Distance from focus to aperture | m |
### Error estimates
`E_err`, `w_err`, and `tau_err` are fractional uncertainties on the energy,
waist, and pulse duration; they are combined in quadrature into `Tot_err` and
written to the log as the systematic uncertainty on the extracted coefficients.
— `E_err`, `w_err`, `tau_err`, as fractions, propagated into the reported
uncertainty
### Simulation parameters
| Parameter | Default | Meaning |
|-------------|---------|-----------------------------------------------------|
| `z_points` | `76` | Number of z-scan points (must be even) |
| `r_points` | `500` | Radial points at the sample |
| `r_max` | `3` | Radial integration limit, in beam waist *w₀* |
| `t_points` | `50` | Temporal points |
| `t_max` | `3` | Temporal integration limit, in pulse duration *τ* |
| `ra_points` | `50` | Radial points at the closed aperture |
| `endpts_%` | `10` | Percentage of edge points to use for normalization |
| `z range` | `15` | Half-width of simulated scan in Rayleigh ranges *z₀*|
| `max_iter` | `100` | Maximum iterations for the parameter refinement |
Memory use scales as `r_points x ra_points x t_points x z_points`, so raising
the grid resolution raises RAM sharply; the interface shows the estimate as you
Binary file not shown.

Before

Width:  |  Height:  |  Size: 109 KiB

After

Width:  |  Height:  |  Size: 98 KiB

BIN
View File
Binary file not shown.

Before

Width:  |  Height:  |  Size: 146 KiB

After

Width:  |  Height:  |  Size: 131 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 138 KiB

After

Width:  |  Height:  |  Size: 123 KiB

+135 -24
View File
@@ -31,6 +31,8 @@ See ZScan_beam_simulation_1_3_4.py for the full derivation notes; the
physics and array shapes here are identical to that translation.
"""
__version__ = "1.5"
import os
import time
import datetime
@@ -65,6 +67,21 @@ def rmmissing(arr):
DEFAULT_ENDPTS_PERCENT = 10.0
# Operation modes. Fitting is the program's original behaviour: a
# measured scan is imported and the simulation compared against it.
# Simulation runs the same physics with no data at all, showing the
# calculated signals alone -- so there is nothing to normalize, fit or
# compare with, and the z range comes from a parameter rather than from
# the data's own extent.
OPERATION_FITTING = "fitting"
OPERATION_SIMULATION = "simulation"
OPERATIONS = (OPERATION_FITTING, OPERATION_SIMULATION)
# Half-width of the simulated scan in Simulation mode, in Rayleigh
# ranges: the curves span -sim_z_range_z0 .. +sim_z_range_z0 times z_0.
DEFAULT_SIM_Z_RANGE_Z0 = 15.0
@dataclass
class ZScanConfig:
# --- file / column parameters ---
@@ -134,6 +151,10 @@ class ZScanConfig:
endpts_percent: float = DEFAULT_ENDPTS_PERCENT # wing size for slope norm, % per side
max_iterations: int = 100 # Refine Fit's Nelder-Mead iteration cap
# --- operation mode ---
operation_mode: str = OPERATION_FITTING
sim_z_range_z0: float = DEFAULT_SIM_Z_RANGE_Z0 # Simulation mode only
# =============================================================================
# SETTINGS PERSISTENCE (save/load ZScanConfig as JSON)
@@ -311,7 +332,7 @@ def load_and_normalize_data(cfg: ZScanConfig):
# PHYSICS SIMULATION
# =============================================================================
def run_simulation(cfg: ZScanConfig, DATA: np.ndarray):
def run_simulation(cfg: ZScanConfig, DATA=None):
"""
Runs the full open/closed-aperture z-scan simulation for the given
config and (already-loaded/normalized) DATA array. Returns a dict
@@ -349,8 +370,13 @@ def run_simulation(cfg: ZScanConfig, DATA: np.ndarray):
# when all three are negative (e.g. -0.5, -0.3, -0.2 -> 0.2), too
# small a pad, pushing the outermost data points past the ends of
# the simulated curve and into extrapolation.
max_offset = max(abs(cfg.Delta_z_OA), abs(cfg.Delta_z_CA), abs(cfg.Delta_z_OACA))
z_range = (np.max(np.abs(DATA[:, 0])) + max_offset) / (z_0 * 1e3)
if DATA is None:
# Simulation mode: there is no measured scan to span, so the
# range is a parameter, in Rayleigh ranges.
z_range = cfg.sim_z_range_z0
else:
max_offset = max(abs(cfg.Delta_z_OA), abs(cfg.Delta_z_CA), abs(cfg.Delta_z_OACA))
z_range = (np.max(np.abs(DATA[:, 0])) + max_offset) / (z_0 * 1e3)
Tot_err = np.sqrt(cfg.E_err ** 2 + cfg.w_err ** 2 + cfg.tau_err ** 2)
@@ -463,6 +489,23 @@ def run_simulation(cfg: ZScanConfig, DATA: np.ndarray):
# padded by the largest offset magnitude, the data should sit
# inside the simulated range anyway.
z_mm = z * 1e3
if DATA is None:
# Nothing to interpolate onto, and nothing to compare against.
# The peak-to-valley figures still describe the simulated
# curves, so they are returned with the data half left NaN;
# build_log_text prints that as "-".
elapsed = time.time() - t_start
return dict(
z=z, z_mm=z_mm, OA=OA, CA=CA, CAOA=CAOA,
OA_interp=None, CA_interp=None, CAOA_interp=None,
OA_chi_square=None, CA_chi_square=None, CAOA_chi_square=None,
deltaOAcomp=np.array([np.nan, 1 - np.min(OA)]),
deltaCAcomp=np.array([np.nan, np.max(CA) - np.min(CA)]),
deltaCAOAcomp=np.array([np.nan, np.max(CAOA) - np.min(CAOA)]),
Io=Io, z_0=z_0, tau=tau, kappa=kappa, Tot_err=Tot_err, z_range=z_range,
elapsed=elapsed,
)
OA_interp = CubicSpline(z_mm, OA)(DATA[:, 5])
OA_chi_square = np.sum(rmmissing(((OA_interp - DATA[:, 6]) ** 2) / OA_interp))
@@ -890,9 +933,49 @@ def make_reference_figure(DATA, norm_OA, norm_CA, do_norm_OA=True, do_norm_CA=Tr
return _finish_figure(fig)
# Fraction of the y span left clear above and below the curves in
# Simulation mode. The panels are autoscaled tight, which in Fitting
# mode is what you want -- the scatter's own spread keeps the extremes
# off the frame -- but a lone smooth curve then runs into the top and
# bottom edges.
SIM_Y_PAD = 0.05
def _pad_y_axis(ax, fraction=SIM_Y_PAD):
"""Widens the y limits by `fraction` of the current span at each
end. Applied after the panel is styled, so it pads what is actually
displayed rather than relying on autoscale's own margins, which the
tight autoscale in _style_panel has already switched off."""
lo, hi = ax.get_ylim()
pad = (hi - lo) * fraction
ax.set_ylim(lo - pad, hi + pad)
def make_fit_figure(cfg: ZScanConfig, DATA, results, line_width=1.25):
"""The Open/Closed aperture panels. With DATA (Fitting mode) each
panel shows the measured points and the simulation interpolated
onto them; with DATA None (Simulation mode) it shows the simulated
curves alone, on the simulation's own z axis."""
fig = Figure(figsize=(9, 4.2))
ax1, ax2 = fig.subplots(1, 2)
if DATA is None:
z_mm = results['z_mm']
sim_line, = ax1.plot(z_mm, results['OA'], '-r', linewidth=line_width, label='Simulation')
_style_panel(ax1, 'Open aperture',
legend_handles=[sim_line], legend_labels=['Simulation'])
if cfg.show_CA:
sim_line2, = ax2.plot(z_mm, results['CA'], '-b', linewidth=line_width, label='Simulation')
title2 = 'Closed aperture'
else:
sim_line2, = ax2.plot(z_mm, results['CAOA'], '-b', linewidth=line_width, label='Simulation')
title2 = 'Closed over open aperture'
_style_panel(ax2, title2, right_hand=True,
legend_handles=[sim_line2], legend_labels=['Simulation'])
_pad_y_axis(ax1)
_pad_y_axis(ax2)
return _finish_figure(fig)
marker_size = _marker_size_for_data(DATA.shape[0])
fit_line, = ax1.plot(DATA[:, 5], results['OA_interp'], '-r', linewidth=line_width, label='Fit')
@@ -949,9 +1032,14 @@ def build_log_text(cfg: ZScanConfig, DATA, results, exported_paths=None) -> str:
file itself, JPG/SVG images, etc.) so the log lists everything
that was exported alongside it.
"""
simulation_only = DATA is None
lines = []
lines.append(f"{datetime.datetime.now()}: Begin Z-scan program (zscan_gui.py / zscan_core.py).")
lines.append(f"Import data file {cfg.import_filepath}.\n")
lines.append(f"Operation mode: {'Simulation' if simulation_only else 'Fitting'}")
if simulation_only:
lines.append("No data imported; the calculated signals are shown alone.\n")
else:
lines.append(f"Import data file {cfg.import_filepath}.\n")
lines.append('Data Columns (1-indexed):')
lines.append(f' z column: {cfg.z_col}')
@@ -972,9 +1060,12 @@ def build_log_text(cfg: ZScanConfig, DATA, results, exported_paths=None) -> str:
lines.append(f' t_points: {cfg.t_points}')
lines.append(f' t_max: {cfg.t_max:6.3f} tau')
lines.append(f' ra_points: {cfg.ra_points}')
resolved_endpts = resolve_endpts(cfg.endpts_percent, DATA.shape[0])
lines.append(f' endpts: {cfg.endpts_percent:6.3f} % per side '
f'({resolved_endpts} leading / {resolved_endpts + 1} trailing points)')
if simulation_only:
lines.append(f' z range: {cfg.sim_z_range_z0:6.3f} z_0 (half-width)')
else:
resolved_endpts = resolve_endpts(cfg.endpts_percent, DATA.shape[0])
lines.append(f' endpts: {cfg.endpts_percent:6.3f} % per side '
f'({resolved_endpts} leading / {resolved_endpts + 1} trailing points)')
lines.append(f' max_iterations: {cfg.max_iterations}\n')
lines.append('Processing Parameters:')
@@ -1015,15 +1106,23 @@ def build_log_text(cfg: ZScanConfig, DATA, results, exported_paths=None) -> str:
lines.append(f' S: {cfg.S:6.3f}')
lines.append(f' d: {cfg.d * 1e3:6.3f} mm\n')
lines.append('DeltaT_PV comparison:')
lines.append(f" Delta_OA_comp: {np.round(results['deltaOAcomp'], 3)} (data / fit)")
lines.append(f" Delta_CA_comp: {np.round(results['deltaCAcomp'], 3)} (data / fit)")
lines.append(f" Delta_CAOA_comp: {np.round(results['deltaCAOAcomp'], 3)} (data / fit)\n")
if simulation_only:
# Only the simulated half of each pair exists, and there is
# nothing to compute a chi-square against.
lines.append('DeltaT_PV (simulated):')
lines.append(f" Delta_OA: {results['deltaOAcomp'][1]:6.3f}")
lines.append(f" Delta_CA: {results['deltaCAcomp'][1]:6.3f}")
lines.append(f" Delta_CAOA: {results['deltaCAOAcomp'][1]:6.3f}\n")
else:
lines.append('DeltaT_PV comparison:')
lines.append(f" Delta_OA_comp: {np.round(results['deltaOAcomp'], 3)} (data / fit)")
lines.append(f" Delta_CA_comp: {np.round(results['deltaCAcomp'], 3)} (data / fit)")
lines.append(f" Delta_CAOA_comp: {np.round(results['deltaCAOAcomp'], 3)} (data / fit)\n")
lines.append('Fit Quality:')
lines.append(f" OA_chi^2: {results['OA_chi_square']:6.3f}")
lines.append(f" CA_chi_2: {results['CA_chi_square']:6.3f}")
lines.append(f" CAOA_chi_2: {results['CAOA_chi_square']:6.3f}\n")
lines.append('Fit Quality:')
lines.append(f" OA_chi^2: {results['OA_chi_square']:6.3f}")
lines.append(f" CA_chi_2: {results['CA_chi_square']:6.3f}")
lines.append(f" CAOA_chi_2: {results['CAOA_chi_square']:6.3f}\n")
lines.append('Error estimates:')
lines.append(f' E_err: {cfg.E_err * 100:6.3f} %')
@@ -1041,12 +1140,18 @@ def build_log_text(cfg: ZScanConfig, DATA, results, exported_paths=None) -> str:
return "\n".join(lines)
def export_results(cfg: ZScanConfig, DATA, results, fit_fig, ref_fig=None):
def export_results(cfg: ZScanConfig, DATA, results, fit_fig, ref_fig=None,
export_basepath=None):
"""
Writes the fit/data CSV, a full log file (via build_log_text, which
lists every exported file), a JPG + SVG snapshot of fit_fig, and
(if provided) a JPG + SVG snapshot of ref_fig (the "Referenced /
Normalized" figure).
With DATA None (Simulation mode) the CSV holds the simulated curves
on the simulation's own z axis, there is no reference figure, and
the output names come from `export_basepath` -- a path chosen by
the caller, since there is no imported file to derive them from.
"""
# Derived from the filename stem rather than by replacing the
# literal substring '.txt' in the full path. That replacement was
@@ -1056,7 +1161,7 @@ def export_results(cfg: ZScanConfig, DATA, results, fit_fig, ref_fig=None):
# overwrote the user's raw data; and for any path with '.txt'
# elsewhere in it (a directory named "2019.txt data", say) it
# substituted there too and wrote somewhere unintended.
root, ext = os.path.splitext(cfg.import_filepath)
root, ext = os.path.splitext(export_basepath if export_basepath else cfg.import_filepath)
stem = root + cfg.extra_label + '_fit'
export_filepath = stem + (ext if ext else '.txt')
logfile_exportpath = stem + '_log.txt'
@@ -1076,13 +1181,19 @@ def export_results(cfg: ZScanConfig, DATA, results, fit_fig, ref_fig=None):
ref_svg_path = stem + '_ref.svg'
paths += [ref_picture_path, ref_svg_path]
export_data = np.column_stack([
DATA[:, 5], DATA[:, 6], results['OA_interp'],
DATA[:, 7], DATA[:, 8], results['CA_interp'],
DATA[:, 9], DATA[:, 10], results['CAOA_interp'],
])
header = ('Position (mm),OA (Data),OA (Fit),Position (mm),CA (Data),CA (Fit),'
'Position (mm),OACA (Data),OACA (Fit)')
if DATA is None:
export_data = np.column_stack([
results['z_mm'], results['OA'], results['CA'], results['CAOA'],
])
header = 'Position (mm),OA (Simulation),CA (Simulation),OACA (Simulation)'
else:
export_data = np.column_stack([
DATA[:, 5], DATA[:, 6], results['OA_interp'],
DATA[:, 7], DATA[:, 8], results['CA_interp'],
DATA[:, 9], DATA[:, 10], results['CAOA_interp'],
])
header = ('Position (mm),OA (Data),OA (Fit),Position (mm),CA (Data),CA (Fit),'
'Position (mm),OACA (Data),OACA (Fit)')
np.savetxt(export_filepath, export_data, delimiter=',', fmt='%.8g',
header=header, comments='', newline='\r\n')
+220 -17
View File
@@ -63,9 +63,19 @@ from zscan_core import (
save_settings,
load_settings,
apply_tight_layout,
OPERATION_FITTING,
OPERATION_SIMULATION,
DEFAULT_SIM_Z_RANGE_Z0,
DEFAULT_ENDPTS_PERCENT,
)
# The "Operation Mode" box's toggle, in display order: (mode, label).
OPERATION_CHOICES = [
(OPERATION_FITTING, "Fitting"),
(OPERATION_SIMULATION, "Simulation"),
]
OPERATION_LABELS = dict(OPERATION_CHOICES)
SETTINGS_PATH = os.path.join(os.path.dirname(os.path.abspath(__file__)), "last_settings.json")
# Starting width of the left parameter panel, and of the plot pane
@@ -195,6 +205,11 @@ class LabeledCheck(ttk.Frame):
def set_enabled(self, enabled: bool):
self.checkbutton.configure(state="normal" if enabled else "disabled")
def is_enabled(self) -> bool:
# Mirrors LabeledEntry, so callers can treat either the same
# way when enabling or disabling a whole box of inputs.
return str(self.checkbutton.cget("state")) != "disabled"
class ResizableFigureCanvas:
"""
@@ -463,13 +478,28 @@ class ZScanApp(tk.Tk):
bar.columnconfigure(column, weight=1, uniform="action_buttons")
def _build_param_fields(self, parent):
sec = add_section(parent, "Operation Mode")
self._configure_mode_toggle_style()
self.operation_mode_var = tk.StringVar(value=OPERATION_FITTING)
self._mode_buttons = []
width = max(len(label) for _, label in OPERATION_CHOICES)
for mode, label in OPERATION_CHOICES:
b = ttk.Radiobutton(sec, text=label, value=mode,
variable=self.operation_mode_var,
command=self._on_operation_mode_change,
style="Mode.Toolbutton", width=width)
b.pack(side="left") # abutting, so the pair reads as one control
self._mode_buttons.append(b)
# --- File ---
sec = add_section(parent, "Data File")
self.filepath_var = tk.StringVar(value="")
row = ttk.Frame(sec)
row.pack(fill="x", pady=2)
ttk.Entry(row, textvariable=self.filepath_var, width=28).pack(side="left", fill="x", expand=True)
ttk.Button(row, text="Browse...", command=self._browse_file).pack(side="left", padx=(4, 0))
self.filepath_entry = ttk.Entry(row, textvariable=self.filepath_var, width=28)
self.filepath_entry.pack(side="left", fill="x", expand=True)
self.browse_button = ttk.Button(row, text="Browse...", command=self._browse_file)
self.browse_button.pack(side="left", padx=(4, 0))
self.delimiter = LabeledEntry(sec, "Delimiter", "", width=10, kind=str,
unit='(blank = auto)')
self.delimiter.pack(fill="x", pady=2)
@@ -496,11 +526,25 @@ class ZScanApp(tk.Tk):
self.flip_REF = LabeledCheck(sec, "flip_REF", False)
self.flip_OA_disp = LabeledCheck(sec, "flip_OA_disp", False)
self.flip_CA_disp = LabeledCheck(sec, "flip_CA_disp", False)
self.show_CA = LabeledCheck(sec, "Show CA (else OA/CA)", True)
self.show_CA = LabeledCheck(sec, "Show CA (else OA/CA)", True,
command=self._on_show_CA_toggle)
for w in (self.use_ref, self.use_freq, self.flip_z, self.do_norm_OA, self.do_norm_CA, self.flip_OA,
self.flip_CA, self.flip_REF, self.flip_OA_disp, self.flip_CA_disp, self.show_CA):
w.pack(fill="x", pady=1)
# The inputs Simulation mode switches off: everything that
# describes a measured file, which that mode has none of.
# "Show CA (else OA/CA)" is deliberately not among them --
# it picks which curve the right-hand panel draws, and both are
# simulated, so it still does something with no data loaded.
self._data_widgets = [
self.delimiter, self.extra_label,
self.z_col, self.CA_col, self.OA_col, self.REF_col, self.FREQ_col,
self.use_ref, self.use_freq, self.flip_z, self.do_norm_OA, self.do_norm_CA,
self.flip_OA, self.flip_CA, self.flip_REF, self.flip_OA_disp,
self.flip_CA_disp,
]
sec = add_section(parent, "Nonlinear Parameters")
self.n_2 = LabeledEntry(sec, "n_2", 10e-19, unit="m^2/W", fit_checkbox=True,
label_width=NONLINEAR_LABEL_CHARS)
@@ -565,9 +609,13 @@ class ZScanApp(tk.Tk):
# unit is spelled out at no cost to the panel width.
self.endpts_percent = LabeledEntry(sec, "endpts", DEFAULT_ENDPTS_PERCENT, kind=float,
allow_negative=False, unit="% per side")
# Simulation mode only: with no data, the scan's extent has to
# be stated rather than measured.
self.sim_z_range_z0 = LabeledEntry(sec, "z range (sim.)", DEFAULT_SIM_Z_RANGE_Z0,
kind=float, allow_negative=False, unit="+/- z_0")
self.max_iterations = LabeledEntry(sec, "Max iterations", 100, kind=int, allow_negative=False)
for w in (self.z_points, self.r_points, self.r_max, self.t_points, self.t_max, self.ra_points,
self.endpts_percent, self.max_iterations):
self.endpts_percent, self.sim_z_range_z0, self.max_iterations):
w.pack(fill="x", pady=2)
ttk.Label(
sec,
@@ -699,6 +747,8 @@ class ZScanApp(tk.Tk):
z_points=self.z_points.get(), r_points=self.r_points.get(), r_max=self.r_max.get(),
t_points=self.t_points.get(), t_max=self.t_max.get(), ra_points=self.ra_points.get(),
endpts_percent=self.endpts_percent.get(),
operation_mode=self.operation_mode_var.get(),
sim_z_range_z0=self.sim_z_range_z0.get(),
max_iterations=self.max_iterations.get(),
)
@@ -765,6 +815,9 @@ class ZScanApp(tk.Tk):
self.t_max.set(cfg.t_max)
self.ra_points.set(cfg.ra_points)
self.endpts_percent.set(cfg.endpts_percent)
self.sim_z_range_z0.set(cfg.sim_z_range_z0)
self.operation_mode_var.set(cfg.operation_mode)
self._apply_operation_mode_to_widgets()
self.max_iterations.set(cfg.max_iterations)
def _load_previous_settings(self):
@@ -854,6 +907,115 @@ class ZScanApp(tk.Tk):
self._embed_figure(self.ref_canvas_holder, self.ref_fig)
return DATA
# Selection colour of Tk's "default" theme (its radio-button
# indicator), so the toggle matches the rest of the panel.
MODE_SELECTED_BG = "#4a6984"
def _configure_mode_toggle_style(self):
"""The Operation Mode box's two radio buttons drawn as a
segmented toggle: a pair of equal-width buttons, the selected
one filled.
Built on ttk's Toolbutton, but with a border on both states: in
the "default" theme a plain Toolbutton draws one only on the
selected option, leaving the other looking like a bare label
rather than something to click. Colours are explicit, so the
toggle looks the same under any ttk theme. Map entries are
tried in order, so the disabled ones -- the buttons are locked
while a run is in flight -- come first."""
style = ttk.Style(self)
style.configure("Mode.Toolbutton", padding=(12, 3), anchor="center",
relief="raised", borderwidth=1, background="#e8e8e6")
style.map("Mode.Toolbutton",
relief=[("selected", "sunken")],
background=[("disabled", "selected", "#9aa8b5"),
("selected", self.MODE_SELECTED_BG),
("disabled", "#e8e8e6"),
("active", "#f4f4f2")],
foreground=[("disabled", "selected", "#eef1f4"),
("disabled", "#a3a3a3"),
("selected", "white")])
def _apply_operation_mode_to_widgets(self):
"""Makes the panel, the buttons and the tabs reflect the
selected mode. Simulation has no measured scan, so everything
that describes one is switched off: the Data File, Data Columns
and Processing Flags inputs, Import, Refine Fit, and the
Referenced / Normalized tab. The simulated z range is the
mirror image -- meaningful only in Simulation."""
simulation = self.operation_mode_var.get() == OPERATION_SIMULATION
for w in self._data_widgets:
w.set_enabled(not simulation)
self.filepath_entry.state(["disabled"] if simulation else ["!disabled"])
self.browse_button.state(["disabled"] if simulation else ["!disabled"])
self.sim_z_range_z0.set_enabled(simulation)
# Refine Fit's iteration cap, and Refine Fit is unavailable
# without data, so the field has nothing to govern here.
self.max_iterations.set_enabled(not simulation)
self.import_button.config(state="disabled" if simulation else "normal")
if simulation:
self.refine_button.config(state="disabled")
# A disabled tab cannot be the selected one.
if simulation and self.notebook.select() == str(self.tab_ref):
self.notebook.select(self.tab_fit)
self.notebook.tab(self.tab_ref, state="disabled" if simulation else "normal")
# 'Use reference/frequency channel' also gate REF/FREQ column,
# but only while the boxes they live in are active at all.
if not simulation:
self._on_use_ref_toggle()
self._on_use_freq_toggle()
self._update_run_button_state()
def _on_show_CA_toggle(self):
"""Show CA picks which curve the right-hand panel draws, and
that curve is chosen while the figure is built -- so the plot
on screen only follows the tick once the run is repeated. Does
it straight away, rather than leaving the panel disagreeing
with the box until the next manual run.
Skipped when there is nothing on screen to bring up to date, or
when a run is already under way (the button is disabled then),
so the tick is free to be set before the first run.
"""
if self.results is None:
return
if str(self.run_button.cget("state")) != "normal":
return
self._on_run()
def _on_operation_mode_change(self):
self._set_operation_mode(self.operation_mode_var.get())
def _set_operation_mode(self, mode):
"""Switches mode and clears any results on screen: they were
produced by the other mode, over a different z range and
against different inputs, so they no longer describe what the
panel says. Imported data is kept, so returning to Fitting does
not mean importing again."""
self.operation_mode_var.set(mode)
self.results = self.fit_fig = None
for holder in (self.fit_canvas_holder,):
for child in holder.winfo_children():
child.destroy()
self._fit_view = None
self.log_text.delete("1.0", "end")
self.export_button.config(state="disabled")
self.refine_button.config(state="disabled")
self._apply_operation_mode_to_widgets()
# Settings are written on exit, as for every other field here.
self.status_var.set(f"Operation mode: {OPERATION_LABELS[mode]}.")
def _set_mode_buttons_enabled(self, enabled: bool):
"""The run happens on a worker thread that reads the config
throughout, so the mode must not change underneath it."""
for b in self._mode_buttons:
b.state(["!disabled"] if enabled else ["disabled"])
def _update_run_button_state(self):
"""Run Simulation stays disabled until a file has been
successfully imported AND every required field (everything
@@ -861,7 +1023,7 @@ class ZScanApp(tk.Tk):
currently disabled (e.g. REF column while 'Use reference
channel' is unchecked) are skipped, since their value doesn't
matter to the simulation while they're inactive."""
if not self._has_imported:
if self.operation_mode_var.get() == OPERATION_FITTING and not self._has_imported:
self.run_button.config(state="disabled")
return
if any(w.is_enabled() and w.is_empty() for w in self._required_entry_fields):
@@ -897,7 +1059,8 @@ class ZScanApp(tk.Tk):
messagebox.showerror("Invalid parameter", str(exc))
return
if not cfg.import_filepath or not os.path.isfile(cfg.import_filepath):
simulation = cfg.operation_mode == OPERATION_SIMULATION
if not simulation and (not cfg.import_filepath or not os.path.isfile(cfg.import_filepath)):
messagebox.showerror("File not found", "Please select a valid data file.")
return
if cfg.z_points % 2 != 0:
@@ -908,6 +1071,7 @@ class ZScanApp(tk.Tk):
self.run_button.config(state="disabled")
self.refine_button.config(state="disabled")
self.export_button.config(state="disabled")
self._set_mode_buttons_enabled(False)
self.status_var.set("Running simulation...")
self.progress.start(12)
self.log_text.delete("1.0", "end")
@@ -917,13 +1081,23 @@ class ZScanApp(tk.Tk):
def _run_worker(self, cfg: ZScanConfig):
try:
DATA, norm_OA, norm_CA = load_and_normalize_data(cfg)
results = run_simulation(cfg, DATA)
ref_fig = make_reference_figure(DATA, norm_OA, norm_CA, cfg.do_norm_OA, cfg.do_norm_CA)
fit_fig = make_fit_figure(cfg, DATA, results)
if cfg.operation_mode == OPERATION_SIMULATION:
# No file is read at all, and there is no
# Referenced/Normalized figure to build. Anything
# already imported is left alone, so switching back to
# Fitting does not mean importing again.
results = run_simulation(cfg, None)
fit_fig = make_fit_figure(cfg, None, results)
self.results, self.fit_fig, self.cfg = results, fit_fig, cfg
else:
DATA, norm_OA, norm_CA = load_and_normalize_data(cfg)
ref_fig = make_reference_figure(DATA, norm_OA, norm_CA,
cfg.do_norm_OA, cfg.do_norm_CA)
results = run_simulation(cfg, DATA)
fit_fig = make_fit_figure(cfg, DATA, results)
self.DATA, self.norm_OA, self.norm_CA = DATA, norm_OA, norm_CA
self.results, self.fit_fig, self.ref_fig, self.cfg = results, fit_fig, ref_fig, cfg
self.DATA, self.norm_OA, self.norm_CA = DATA, norm_OA, norm_CA
self.results, self.fit_fig, self.ref_fig, self.cfg = results, fit_fig, ref_fig, cfg
self.after(0, self._on_run_success)
except Exception:
@@ -931,26 +1105,31 @@ class ZScanApp(tk.Tk):
self.after(0, self._on_run_error, tb)
def _on_run_success(self):
simulation = self.cfg.operation_mode == OPERATION_SIMULATION
# Reads the results off self rather than taking them as
# arguments: the worker has already stored every one of them
# there, so passing the same objects through as well was two
# copies of the same handoff. Only ever one run is in flight --
# Run is disabled for the duration.
self._embed_figure(self.ref_canvas_holder, self.ref_fig)
if not simulation:
self._embed_figure(self.ref_canvas_holder, self.ref_fig)
self._embed_figure(self.fit_canvas_holder, self.fit_fig)
self.log_text.delete("1.0", "end")
self.log_text.insert("1.0", build_log_text(self.cfg, self.DATA, self.results))
self.log_text.insert("1.0", build_log_text(self.cfg, self._results_data(), self.results))
self.progress.stop()
self.status_var.set("Done.")
self._set_mode_buttons_enabled(True)
self._update_run_button_state()
self.refine_button.config(state="normal")
# Nothing to refine against without data.
self.refine_button.config(state="disabled" if simulation else "normal")
self.export_button.config(state="normal")
self.notebook.select(self.tab_fit)
def _on_run_error(self, tb_text):
self.progress.stop()
self._set_mode_buttons_enabled(True)
self.status_var.set("Error.")
self._update_run_button_state()
self.refine_button.config(state="disabled")
@@ -1066,11 +1245,34 @@ class ZScanApp(tk.Tk):
self.notebook.select(self.tab_log)
messagebox.showerror("Refine Fit failed", tb_text.strip().splitlines()[-1])
def _results_data(self):
"""The data the current results describe: None after a
simulation, whatever was imported after a fit. self.DATA can
hold an imported scan even in Simulation mode, since running a
simulation no longer discards it."""
if self.cfg is not None and self.cfg.operation_mode == OPERATION_SIMULATION:
return None
return self.DATA
def _on_export(self):
if self.results is None:
return
export_basepath = None
if self.cfg.operation_mode == OPERATION_SIMULATION:
# No imported file to take the output names from, so ask
# where to put them. The chosen name is the base: the usual
# _fit / _fit_log / .jpg / .svg names are built from it.
export_basepath = filedialog.asksaveasfilename(
title="Export simulation as",
defaultextension=".txt",
filetypes=[("Text files", "*.txt"), ("All files", "*.*")])
if not export_basepath:
return
try:
export_paths = export_results(self.cfg, self.DATA, self.results, self.fit_fig, self.ref_fig)
export_paths = export_results(self.cfg, self._results_data(), self.results,
self.fit_fig,
None if export_basepath else self.ref_fig,
export_basepath=export_basepath)
except Exception:
tb = traceback.format_exc()
messagebox.showerror("Export failed", tb.strip().splitlines()[-1])
@@ -1083,7 +1285,8 @@ class ZScanApp(tk.Tk):
# block on every repeat export, and formatted it differently
# from the identical listing inside the exported _log.txt.
self.log_text.delete("1.0", "end")
self.log_text.insert("1.0", build_log_text(self.cfg, self.DATA, self.results, export_paths))
self.log_text.insert("1.0",
build_log_text(self.cfg, self._results_data(), self.results, export_paths))
self.notebook.select(self.tab_log)
messagebox.showinfo("Export complete", "Exported:\n" + "\n".join(export_paths))