30 Commits
Author SHA1 Message Date
manuel 49bc1dc644 Update README.md 2026-11-17 00:13:07 +00:00
manuel 520542ee1b Merge pull request 'Semi analytical propagator' (#5) from SemiAnalyticalPropagator into main
Reviewed-on: #5
2026-11-16 17:44:51 +00:00
manuel 1bc882e163 Upload files to "docs" 2026-11-16 17:43:00 +00:00
manuel 50d0d27464 Upload files to "/" 2026-11-16 17:40:42 +00:00
manuel 45efc8239d Upload files to "/" 2026-11-16 17:40:21 +00:00
manuel d7ab1b823e Merge pull request 'Simulation mode' (#4) from simulation_mode into main
Reviewed-on: #4
2026-09-30 15:21:49 +00:00
manuel 98e95180cc Upload files to "/" 2026-09-30 15:20:45 +00:00
manuel 38c09a4272 Upload files to "/" 2026-09-30 15:20:31 +00:00
manuel cc67401de9 Upload files to "docs" 2026-09-30 15:19:54 +00:00
manuel 6d7996ff30 Upload files to "docs" 2026-09-30 15:17:57 +00:00
manuel 61dbd0452b Merge pull request 'Pump probe mode' (#3) from pump_probe_mode into main
Reviewed-on: #3
2026-09-23 01:20:45 +00:00
manuel 667c37fcb5 Upload files to "/" 2026-09-23 01:18:42 +00:00
manuel 526185a980 Upload files to "docs" 2026-09-23 01:16:41 +00:00
manuel f593c3ff07 Upload files to "/" 2026-09-23 01:16:19 +00:00
manuel cc5f7622cf Upload files to "/" 2026-09-23 01:15:43 +00:00
manuel 4c4ec2d1ce Update README.md 2026-09-21 22:55:59 +00:00
manuel 7cd523b5db Update README.md 2026-09-21 13:32:39 +00:00
manuel 5d8a132031 Update README.md 2026-09-21 13:29:26 +00:00
manuel 32f335562f Update README.md 2026-09-21 13:27:22 +00:00
manuel a6b56dabe3 Update README.md 2026-09-21 13:18:15 +00:00
manuel f3a760bc62 Update README.md 2026-09-21 13:10:46 +00:00
manuel 81c7c3234c Update README.md 2026-09-21 11:41:15 +00:00
manuel 1f324d678c Update README.md 2026-09-21 11:40:34 +00:00
manuel 56430a6202 Update README.md 2026-09-21 11:38:27 +00:00
manuel c1187cd846 Update README.md 2026-09-21 11:37:42 +00:00
manuel 03acb17de4 Update README.md 2026-09-21 11:36:44 +00:00
manuel bc06521601 Update README.md 2026-09-17 16:37:00 +00:00
manuel 6cf2bf4b8a Merge pull request 'Update README.md' (#2) from remove_port_notes into main
Reviewed-on: #2
2026-09-12 20:30:47 +00:00
manuel cb12b8cfc7 Update README.md 2026-09-12 20:30:39 +00:00
manuel 67dbda7c19 Merge pull request 'Add readme' (#1) from add_readme into main
Reviewed-on: #1
2026-09-12 20:27:44 +00:00
8 changed files with 2382 additions and 447 deletions
+359
View File
@@ -0,0 +1,359 @@
# Changelog
All notable changes to BD Fresnel are documented in this file.
The format is based on [Keep a Changelog](https://keepachangelog.com/en/1.1.0/).
## [3.0] - 2026-11-14
### Added
- **Semi-analytical** algorithm, selectable from a third toggle in the
Operation mode box alongside **Fresnel propagation**:
- Instead of propagating the exit field to the detector by FFT, it
uses closed-form expressions for the power difference and total at
the detector, already integrated over the detector plane. Only an
integral over time at each delay remains.
- The time window runs +/- 5T about each delay, where T = tau_p/tau_e.
- Transmission is the energy total normalised to its value before the
pump arrives: the first delay point when fitting, and
min(-3 rho, -3) tau_e when simulating, so a thin sample with
rho -> 0 still normalises away from the peak.
- `X_num` and `X_max` are disabled in this mode: the expressions are
already integrated over space, so there is no spatial grid.
- Applies to both measurement modes. In pump probe the probe is
centred, x_0 = 0, so the deflection term vanishes identically and
the transmission alone is calculated.
- Both algorithms are kept so results can be compared. Switching
discards the current result, which belongs to the other method.
- The algorithm is saved with the other settings and recorded in the
parameter log.
- The absorptive term in the deflection expression carries a
PROVISIONAL coefficient, `SA_ABSORPTIVE_FACTOR`. As derived, that
term matched neither the sign nor the magnitude of the Fresnel
result: a purely absorptive mechanism disagreed by a factor of
about -69, with correlation exactly -1. Dividing by
D = d / (pi w_0_p^2 / lambda_p) = d / z_0_p accounts for the distance and
wavelength dependence exactly, and is independent of sample
thickness at constant alpha_2_exp*l; the remaining -1/(1 + 2W^2) was
measured against the Fresnel path rather than derived. With it the
two methods agree to 0.5% for mechanisms with a refractive part and
4.5% for purely absorptive ones. It is isolated in one function
pending a corrected derivation.
- The parameter log's `Calculated Parameters (pump)` section reports
`sigma_e`, the normalised pump linear absorption `alpha_e * L / 2`.
It sits next to `T_lin`, which restates it: with no pump two-photon
absorption `T_lin = (1 - R_p) exp(-2 sigma_e)`. Read from the
parameters rather than the result, so it is reported for either
algorithm.
- The `Other` panel and the parameter log's `Other` section both report
`eta (peak)` and `Gamma (peak)`, the largest nonlinear phase and
absorption exponent anywhere on the grid, from whichever algorithm
produced the result. These are the only readouts in those panels that
come from the result rather than from the parameters, since they are
peaks over the whole (T, T_d) grid and cannot be had without running
the calculation. They therefore show `--` until a Fit or Simulate
completes, and return to `--` whenever that result is discarded, so a
stale phase is never displayed beside freshly edited parameters.
`eta (peak)` is the yardstick for the semi-analytical algorithm's
validity: its `dP` is first order in the response while Fresnel
propagation keeps every order, so the two agree only while the phase
is small. On the 4-layer mechanisms the peak of `DeltaEoE` sits at
the same delay to within 0.0003 tau_e at `eta (peak)` = 0.14, but
0.0035 at 1.41, 0.077 at 5.6 and 0.36 at 14.1. Holding `eta (peak)`
fixed, the agreement is unaffected by sample thickness (0.05 to
2 mm), by walk-off (`rho` 0.04 to 1.7) and by pump absorption
(`sigma_e` 0 to 10), so this one number sets the regime. Both
algorithms report it to within 2e-5 of each other.
### Changed
- **Both beams are now explicitly subscripted: the pump carries `_e`
(excitation) and the probe carries `_p`.** This restores the
convention the original MATLAB used, which the Python port had
partly inverted (`_p` for the pump) and partly dropped (no suffix
for the probe). No beam quantity is unsubscripted any more; the only
unsuffixed parameters left are the ones belonging to neither beam --
the sampling grid, the sample geometry (`l`, `d`, `shift`), the
relative offset `x_0`, and the walk-off `rho`.
| pump: was | now | | probe: was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_FWHM` | `tau_p_FWHM` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `w_0` | `w_0_p` |
| `w_0p` | `w_0_e` | | `lambda_` | `lambda_p` |
| `lambda_p` | `lambda_e` | | `R` | `R_p` |
| `R_p` | `R_e` | | `alpha` | `alpha_p` |
| `alpha_p` | `alpha_e` | | `n` | `n_p` |
| `n_p` | `n_e` | | `dndl` | `dndl_p` |
| `dndl_p` | `dndl_e` | | `tau` | `tau_p` |
| `alpha_2d` | `alpha_2d_e` | | `ng` | `ng_p` |
| `tau_p` | `tau_e` | | `z_0` | `z_0_p` |
| `sigma_p` | `sigma_e` | | `Tlin` | `Tlin_p` |
| `I_0_p` | `I_0_e` | | | |
| `ng_p` | `ng_e` | | | |
| `z_0_p` | `z_0_e` | | | |
| `Tlin_p` | `Tlin_e` | | | |
| `sigma_p2` / `sigma_p20` | `sigma_e2` / `sigma_e20` | | | |
| `a_p_0`, `W_0_p`, `I_p_pulse` | `a_e_0`, `W_0_e`, `I_e_pulse` | | | |
Note that six probe names -- `tau_p_FWHM`, `lambda_p`, `R_p`,
`alpha_p`, `n_p`, `dndl_p` -- are spelled exactly like what were
**pump** names before this release. Reading an old log or settings
file alongside a new one needs care; see the settings note below for
how the program itself is protected.
The pump pass renamed 389 identifier occurrences textually; the
probe pass was done by rewriting 116 exact AST node positions
instead, because `n`, `R`, `alpha` and `tau` are overloaded in this
codebase (lambda parameters, the author's initials in the copyright
line, the semi-analytical formula's geometric `R`, a diagnostics
dict key) and no text pattern distinguishes them.
| was | now | | was | now |
|-----|-----|-|-----|-----|
| `E_p` | `E_e` | | `tau_p` | `tau_e` |
| `tau_p_FWHM` | `tau_e_FWHM` | | `sigma_p` | `sigma_e` |
| `w_0p` | `w_0_e` | | `I_0_p` | `I_0_e` |
| `lambda_p` | `lambda_e` | | `ng_p` | `ng_e` |
| `R_p` | `R_e` | | `z_0_p` | `z_0_e` |
| `alpha_p` | `alpha_e` | | `Tlin_p` | `Tlin_e` |
| `n_p` | `n_e` | | `sigma_p2` | `sigma_e2` |
| `dndl_p` | `dndl_e` | | `sigma_p20` | `sigma_e20` |
| `alpha_2d` | `alpha_2d_e` | | `a_p_0` | `a_e_0` |
`w_0p` gains the separating underscore it was missing, so the field
name finally matches the variable that held it (`w_0_p`) and its
siblings `z_0_e` and `I_0_e`. `alpha_2d_e` keeps the `d` for
degenerate.
- **The Electronic mechanism's parameters are renamed `alpha_2e` ->
`alpha_2el` and `n_2e` -> `n_2el`**, since their `e` meant
*electronic* and would otherwise collide with `_e` for excitation --
the pump's degenerate two-photon coefficient would have wanted the
name `alpha_2e`, which was taken. `_e` now means excitation and
nothing else.
- `BD_3_level_triplet`, `I_e_func` and `excite_prop` needed no
renaming at all: transliterated from the MATLAB, they already used
`_e` for the pump and `_p` for the probe, so `n_g_p`, `v_p` and
`I_p` inside them were correct all along. With both beams now
subscribed to that convention, the whole file reads against the
MATLAB without translation.
- **`last_settings.json` written by an earlier version is now refused
rather than misread.** Saved settings carry a `settings_schema`
stamp, and a file without the current one is rejected with a message
explaining why. This is not housekeeping: because six probe field
names are spelled exactly like former pump keys, loading an old file
by name alone would have installed the pump's wavelength, index,
reflectivity, absorption and dispersion as the *probe's* -- every
number plausible, every result wrong. Re-enter the parameters once
and they save in the new layout. Any other unrecognised key is still
dropped with a note on stderr.
- Log and panel labels follow their fields on both sides: `n_g_e`,
`sigma_e`, `T_lin_e`, `z_0_e`, `I_0_e` for the pump and `n_g_p`,
`T_lin_p`, `z_0_p` for the probe, with the beam parameters and
material blocks likewise. The GUI's pump calculated-parameters panel
also gains a `sigma_e` readout, which it had not displayed before.
- `T_lin_p` and `T_lin_e` are labelled `T_lin_p (transmission)` and
`T_lin_e (transmission)` in both the panel and the log, so the
quantity is named and not just abbreviated. The log's value column
moved from 25 to 29 to fit them, and the panel's label column from 20
to 23 characters -- which also squares up `z_0_p (Rayleigh range)`,
`z_0_e (Rayleigh range)` and `I_0_e (peak irradiance)`, all of which
had been overrunning the old 20 and pushing their own values out of
line.
- The rename is numerically inert: across 8 mechanism types x 2
algorithms x 3 pump-absorption configurations (49 cases, 3275
values), `DeltaEoE`, `T`, `Delta_n`, `eta_peak` and `Gamma_peak` are
bit-identical to the pre-rename code, and `pyflakes` reports zero
warnings before and after.
- Transmission y-axis tick labels are limited to three significant
digits, so "99.75" reads "99.8". The count is a floor rather than a
cap: a shallow scan spanning a few hundredths of a percent would
round every tick to "100", so digits are added only where that would
happen. The deflection axis is unaffected.
- The reference list in the README and the parameter log follows Optica
style: every author listed, initials first, abbreviated journal,
volume, full page range, year. Author lists and page ranges were
checked against the published papers.
- The duplicate supplementary-material citation is dropped, leaving two
references.
- The parameter log is written as UTF-8. The citations use typographic
quotes and an en dash, which the locale's encoding cannot always
represent.
### Fixed
- The instantaneous (Electronic) response for a sample with both
walk-off and pump absorption is evaluated through the scaled
complementary error function `erfcx` instead of the form in
`BD_Fresnel_func_ni.m`. That form multiplied `exp(sigma_e^2/rho^2 +
2 sigma_e u/rho)` by a difference of error functions falling to zero,
so the product was lost to cancellation well before it overflowed:
at `rho = 0.4336` (l = 0.5 mm) it was already wrong over 8.6% of the
delay axis at `sigma_e = 2.5` (alpha_e = 100 cm^-1), **returning
exactly 0.0 with no NaN to signal it**, and returned NaN above
`sigma_e = 3`. The usable ceiling on `alpha_e` for an Electronic
mechanism at that thickness was therefore about 60 cm^-1, not the
~120 where NaN first appeared. The rearrangement is algebraic, with
every surviving exponent non-positive; it reproduces the original
evaluated at 600 decimal digits to 1e-16..3e-13 relative over
`sigma_e` = 0.25 to 10 and `u` = -3 to 18, both where the original
works and where it does not.
- Pump absorption is applied to non-instantaneous mechanisms when the
walk-off is exactly zero. Substituting `T1 = (T+T_d) - rho +
rho*zeta` shows the `rho != 0` branch to be a depth average over
`atten_fac`, whose `rho -> 0` limit is the response at one instant
times the *mean* of `atten_fac`; the original used the bare response.
The dropped factor is `(1 - exp(-2 sigma_e))/(2 sigma_e)` for linear
pump absorption, so the response was previously **independent of
`alpha_e` altogether** in this case -- identical at `alpha_e` = 0 and
200 cm^-1. It was 1.27x too large at `alpha_e` = 10 cm^-1 and
l = 0.5 mm, and 10x at 200 cm^-1. The two branches now agree to nine
digits across `rho = 0`. This affects only samples with `ng_p` exactly
equal to `ng_e` (for example no dispersion entered at either
wavelength) *and* non-zero pump absorption; with `alpha_e = alpha_2d_e
= 0` the mean is exactly 1 and results are bit-identical to before.
- Pump absorption through the sample depth, `atten_fac`, is computed
from the closed-form solution of
`dI_e/dz = -alpha_e I_e - alpha_2d_e I_e^2` rather than the two-branch
expression carried over from `BD_Fresnel_func_ni.m`. That expression's
pump two-photon branch, `sqrt((B1 B2)/sigma_e)`, failed three ways: it
did not reduce to its own `sigma_e2 == 0` branch as `alpha_2d_e -> 0`
(it decayed at half the correct rate), it divided by zero whenever
`alpha_e` was zero, and it took the square root of a negative number
whenever `sigma_e20 > sigma_e`. The net effect was that **every run
combining a non-zero `alpha_2d_e` with a non-instantaneous mechanism
returned NaN at every delay** -- pump two-photon absorption worked
only for the Electronic mechanism, which does not use `atten_fac`.
Dropping the stray square root recovers that expression as the
linearisation of the exact one in `sigma_e20`, which is how the
intent was identified. Results for `alpha_2d_e = 0` are bit-identical
to before; the new form agrees with numerical integration of the
pump propagation equation to 2e-12 relative over `sigma_e` and
`sigma_e20` from 0 to 20, including both limits.
- A negative `alpha_2d_e` large enough to make the pump diverge inside
the sample (two-photon gain, no finite depth average) is now refused
with a message naming the largest `|alpha_2d_e|` that works for the
current thickness and pump irradiance, rather than silently returning
a meaningless attenuation of order 1e12.
- `mpmath` is imported only where it is used, in the pump two-photon
absorption term. Importing it at module level made an optional
dependency fatal at startup, so the program would not run at all
without it. If that term is ever reached without mpmath installed,
the error now says which package is missing and why.
## [2.6] - 2026-09-30
### Added
- **Simulation** run mode: a second toggle in the Operation mode box,
offering **Fitting** and **Simulation**. Fitting is the default and
behaves as before.
- Simulation mode, for computing a signal without a measurement:
- No file is imported. **Import...** and the data column and
delimiter fields are disabled.
- The delay range is entered as `T_d_min` and `T_d_max` (in `tau_p`)
in the Simulation parameters box. In Fitting mode these are taken
from the imported scan and the fields are disabled.
- Only the calculated curves are plotted, without data markers, and
the plot legend reads **Simulated** rather than Fit.
- The **Fit** button is relabelled **Simulate**, and is enabled by
valid parameters alone rather than by an imported file.
- The export holds the calculated signals on their own delay grid,
with no data columns to pair them with. The parameter log omits the
import path and the data column section.
- The mode combines with the measurement mode: Pump probe and
Simulation together give a single Transmission panel and a
two-column table, as Pump probe does when fitting.
- The run mode is saved with the other settings and recorded in the
parameter log.
### Changed
- The **Mode** box is renamed **Operation mode** and moved to the top of
the parameter panel, above Data columns. The parameter log and status
messages use the new name, and the log records both modes on one line.
- Changing run mode discards the current result, which described the
other mode's delay range or a measurement the new mode does not show.
Switching to Simulation sets the imported scan aside and switching
back reloads it. The run mode cannot be changed while a fit runs.
- `inputs_valid` takes a `require_data` argument, so Simulation can
enable its action button without an imported file. Fitting is
unaffected.
## [2.5] - 2026-09-21
### Added
- **Mode** box, below Data columns: a two-button toggle selecting
**Beam deflection** or **Pump probe**. Beam deflection is the default
and behaves as before.
- Pump probe mode, for measurements with the probe centred on the pump:
- Only the delay and transmission columns are required, so a
two-column scan can be imported. The DeltaEoE column is ignored and
its field disabled.
- `x_0` is fixed at 0 and cannot be edited.
- Only the Transmission plot is displayed and exported. The exported
image is named `<name>_fit_transmission.jpg` / `.svg` and is 3.25 in
wide, a single column. The exported data table holds delay, T (data)
and T (fit).
- The mechanism pull-downs offer the absorptive (NLA) and mixed
(both) mechanisms; a mixed mechanism contributes its absorptive
part. The purely refractive (NLR) mechanisms, which cannot change
the transmission, are excluded. Switching to pump probe empties any
slot holding one; switching back restores it, provided the slot is
still empty.
- The selected mode is saved with the other settings and recorded in the
parameter log.
### Changed
- Changing mode discards the current fit, which was computed with the
other mode's settings, and re-reads the imported file under the new
mode's column requirements. A file the new mode cannot use is cleared
with an explanation, and loaded again on switching back. The mode
cannot be changed while a fit runs.
- The source files carry the GPLv3 notice.
### Fixed
- Values such as `nan`, `inf` or `1e999` are rejected in parameter fields.
They previously turned the fit to NaN, and crashed the mechanism
parameters dialog.
- An invalid entry in a numeric field reverts to its previous value, as the
integer fields and the mechanism dialog already did, instead of becoming 0.
- Every parameter change is saved as it is made. Numeric fields, mechanism
choices and the diagnostics option were previously saved only on Import,
Fit, Export or Exit, so a crash lost them.
- Changing a column number or the delimiter re-reads only a file imported in
the current session. Straight after launch it could load the previous
session's file, or report an error about one that had since moved.
- When a file cannot be read with a new column number or delimiter, its data
and fit are cleared. They previously stayed on screen, and could be
exported, under settings that no longer described them.
- The data columns in use must each be different. Two quantities could
previously be read from the same column without any warning.
- The x tick label at the join between the Transmission and Deflection plots
is hidden when it collides with its neighbour. A rounding error let some
such labels through.
## [2.4] - 2026-09-21
First release recorded in this changelog. Earlier history is not documented
here.
### Fixed
- README parameter tables corrected to match the program's window: the
default T and DeltaEoE data columns were swapped, and several defaults,
labels and descriptions disagreed with what the interface shows.
+258 -80
View File
@@ -4,11 +4,20 @@ Beam-deflection pump–probe simulator and fitting tool. A Python port of the
MATLAB `BD_Fresnel_GUI` suite.
The program models a weak probe beam crossing a sample that has been excited by
a strong pump, propagates the perturbed probe field to a detector by Fresnel
diffraction, and computes the transmission `T` and normalised beam deflection
`ΔE/E` as a function of pump–probe delay. Measured scans can be imported and
compared against the simulation, and the result exported as data, a log, and
publication-sized figures.
a strong pump, propagates the perturbed probe field to the detector and computes
the transmission `T` and normalised beam deflection `ΔE/E` as a function of
pump–probe delay. Measured scans can be imported and compared against the
simulation, and the result exported as data, a log, and publication-sized
figures.
Two measurement modes are supported. **Beam deflection** fits both signals.
**Pump probe** is for measurements with the probe centred on the pump, where
there is no deflection: it fits the transmission alone, and needs only delay
and transmission data.
The program also runs without a measurement. In **Simulation** mode nothing is
imported: the signal is computed from the parameters alone, over a delay range
entered by hand, and only the calculated curves are plotted and exported.
![BD Fresnel fitting a measured scan](docs/screenshot.png)
@@ -22,7 +31,17 @@ publication-sized figures.
parameter `rho`.
- Excited-state absorption via a five-level population model (S₀, S₁, S₂, T₁,
T₂) solved through the sample depth for a range of radial irradiances.
- Side-by-side transmission and deflection plots with imported data overlaid.
- Side-by-side transmission and deflection plots, with imported data overlaid
when there is any.
- Beam deflection and pump probe measurement modes. Pump probe reads a
two-column delay/transmission scan, fixes the probe on the pump axis, and
offers only the mechanisms that can change the transmission.
- Fitting and simulation run modes. Simulation computes the signal with no
data imported, over a delay range entered in the panel.
- Two interchangeable algorithms. Fresnel propagation carries the exit field to
the detector by FFT; the semi-analytical method uses closed-form detector
power expressions instead, needing no spatial grid and running about 32x
faster, at the cost of holding only to first order in the nonlinear response.
- Optional diagnostic figures showing each mechanism's response function before
and after convolution, plus the ESA populations and beam transmissions.
- Export of the data/fit comparison, a full parameter log, and figures at
@@ -54,112 +73,271 @@ python bd_fresnel_gui.py
The window opens with the parameter panel on the left and three tabs on the
right: **Fitting**, **Diagnostics**, and **Parameter log**.
A typical session:
Fitting a measured scan:
1. Set the **Data columns** to match your file, and the delimiter.
2. Press **Import…** and choose a scan. The plots show the measured data.
3. Fill in the beam, material and geometry parameters, and configure one or
1. Under **Operation mode**, choose **Beam deflection** or **Pump probe**,
leave the second toggle on **Fitting**, and pick an algorithm on the third:
**Fresnel propagation** or the faster **Semi-analytical**.
2. Set the **Data columns** to match your file, and the delimiter.
3. Press **Import…** and choose a scan. The plots show the measured data.
4. Fill in the beam, material and geometry parameters, and configure one or
more mechanisms with the **Params…** buttons.
4. Press **Fit** to run the simulation and overlay it on the data.
5. Press **Export…** to write the results.
5. Press **Fit** to run the simulation and overlay it on the data.
6. Press **Export…** to write the results.
**Fit** stays disabled until a file is imported, and **Export** until a fit has
completed.
Simulating without a measurement:
1. Under **Operation mode**, choose **Simulation**. **Import…** and the data
column fields are disabled, and **Fit** becomes **Simulate**. The algorithm
toggle works the same way as in Fitting mode.
2. Set `T_d_min` and `T_d_max` in **Simulation parameters** to the delay range
to compute over. In Fitting mode these come from the imported file, so they
are editable only here.
3. Fill in the parameters and mechanisms as above.
4. Press **Simulate**, then **Export…**.
**Fit** stays disabled until a file is imported; **Simulate** needs only valid
parameters. **Export** stays disabled until a fit or simulation has completed.
Changing the mode, a column number or the delimiter re-reads the imported file.
Any fit is discarded, since it belonged to the previous settings. If the file
cannot be read with the new settings, its data is cleared rather than left on
screen, and it is read again once the settings allow.
Parameters are saved to `last_settings.json` beside the scripts when they
change, and restored at the next launch. The data file itself is not restored.
## Input data format
A delimited text file with one header line, then one row per delay point. Three
columns are required; which ones is set in the **Data columns** box, so extra
columns can be present and ignored.
A delimited text file with one header line, then one row per delay point. Beam
deflection needs three columns and pump probe two; which ones is set in the
**Data columns** box, so extra columns can be present and ignored. Each
quantity must come from a different column.
| Quantity | Units | Default column |
| --- | --- | --- |
| Delay `τ_d` | fs | 1 |
| `ΔE/E` | fractional | 2 |
| `T` | fractional (1.0 = no change) | 3 |
| Quantity | Units | Default column | Needed in |
|----------|------------------------------|----------------|----------------------|
| `τ_d` | fs | 1 | both modes |
| `ΔE/E` | fractional | 2 | Beam deflection only |
| `T` | fractional (1.0 = no change) | 3 | both modes |
The delimiter field takes a single character, `\t` for a tab, or is left blank
to split on any run of whitespace.
## Parameters
### Data columns (1-indexed)
| Variable | Default | Column contents |
|-------------------|---------|---------------------------------|
| `tau_d column` | `1` | Delay column (fs) |
| `T column` | `3` | Transmission data column |
| `DeltaEoE column` | `2` | Deflection data column |
| `Delimiter` | `,` | Data column delimiter character |
### Operation mode
Three independent toggles. Any combination is valid.
| Toggle | Option | Effect |
|-------------|-----------------------|--------------------------------------------------|
| Measurement | `Beam deflection` | Transmission and deflection, offset probe |
| | `Pump probe` | Transmission only, centered probe |
| Run | `Fitting` | Compare the calculation against an imported scan |
| | `Simulation` | Calculate without a scan, over an entered range |
| Algorithm | `Fresnel propagation` | Propagate the exit field to the detector by FFT |
| | `Semi-analytical` | Closed-form detector power, no spatial grid |
#### Algorithm
**Fresnel propagation** is the original method. The field at the exit face is
built on an (x, y) grid, propagated to the detector by FFT, and integrated over
the detector halves to get the power difference and total at each instant.
**Semi-analytical** skips the propagation. It evaluates closed-form expressions
for the detector power difference `dP` and total `P`, already integrated over
the detector plane, then integrates each over time at every delay to get the
energy difference `dE` and total `E`. The deflection is `dE/E` and the
transmission is `E` normalised. With no spatial grid to size, `X_num` and
`X_max` are greyed out; every other parameter, `Delta_n` included, is
unaffected. On the four-layer graphene example it runs in 0.11 s against 3.65 s,
about **32x faster**.
The trade-off is that `dP` is **first order in the nonlinear response**, where
the Fresnel path keeps every order. The two therefore agree only while the
phase is small, which the `eta (peak)` line of the parameter log reports:
| `eta (peak)` | Peak of `DeltaEoE` displaced by |
|--------------|---------------------------------|
| 0.14 rad | 0.0003 tau_e |
| 1.41 rad | 0.0035 tau_e |
| 5.64 rad | 0.077 tau_e |
| 14.1 rad | 0.36 tau_e |
Below roughly 1 rad the two are interchangeable, and the four-layer graphene
example sits at 0.049 rad with a correlation of 1.000000 and amplitudes within
0.5%. Above a few rad the semi-analytical curve shifts noticeably and is no
longer a substitute. Sample thickness, walk-off and pump absorption do not
themselves affect the agreement once `eta (peak)` is held fixed.
The remaining 0.5% amplitude offset is the on-axis approximation: the Fresnel
path attenuates by `exp(-2 a_e^2 Gamma)` across the probe profile, where `a_e`
is the pump amplitude profile, while the semi-analytical form uses the on-axis
`exp(-2 x_0^2)`.
One coefficient in `dP`'s absorptive term, `SA_ABSORPTIVE_FACTOR`, is at present
fitted against the Fresnel path rather than derived. It is isolated in a single
function in `bd_fresnel_core.py`, with the measurements behind it recorded
there.
The transmission needs a reference delay, taken from before the pump arrives.
In **Fitting** mode it is the first delay point of the imported scan; in
**Simulation** mode it is `min(-3 rho, -3)` tau_e, which follows the walk-off
when that is the larger scale and is three pulse widths otherwise, so a thin
sample still normalises away from the peak.
### Simulation parameters
| Variable | Default | Column contents |
|-----------|---------|-------------------------------------------------|
| `X_num` | `50` | Number of spatial points, Fresnel only |
| `X_max` | `5.0` | Range of spatial sampling (w_0_p), Fresnel only |
| `T_num` | `100` | Number of temporal points |
| `T_max` | `5.0` | Range of temporal sampling (tau_e) |
| `T_d_num` | `150` | Number of delay points over range |
| `T_d_min` | `-5.0` | Delay range start (tau_e), Simulation only |
| `T_d_max` | `5.0` | Delay range end (tau_e), Simulation only |
`X_num` and `X_max` size the spatial grid the Fresnel method propagates, so the
semi-analytical method greys them out.
### Excitation beam parameters
| Variable | Default | Column contents |
|--------------|---------|----------------------------------|
| `E_e` | `1.36` | Excitation pulse energy (uJ) |
| `tau_e_FWHM` | `55.0` | Excitation pulse duration (fs) |
| `w_0_e` | `246.0` | Excitation beam waist (um) |
| `lambda_e` | `800.0` | Excitation pulse wavelength (nm) |
### Probe beam parameters
| Variable | Default | Column contents |
|--------------|---------|-----------------------------|
| `tau_p_FWHM` | `60.0` | Probe pulse duration (fs) |
| `w_0_p` | `43.0` | Probe beam waist (um) |
| `lambda_p` | `650.0` | Probe pulse wavelength (nm) |
### Material parameters at excitation wavelength
| Variable | Default | Column contents |
|--------------|-------------|--------------------------------|
| `R_e` | `0.0` | Reflectivity |
| `alpha_e` | `0.0` | Linear absorption (cm^-1) |
| `n_e` | `1.4533` | Linear index |
| `dndl_e` | `-0.017284` | First order dispersion (um^-1) |
| `alpha_2d_e` | `0.0` | 2 photon absorption (e-11 m/W) |
### Material parameters at probe wavelength
| Variable | Default | Column contents |
|-----------|-------------|--------------------------------|
| `R_p` | `0.0` | Reflectivity |
| `alpha_p` | `0.0` | Linear absorption (cm^-1) |
| `n_p` | `1.4565` | Linear index |
| `dndl_p` | `-0.027158` | First order dispersion (um^-1) |
### Measurement parameters
| Variable | Default | Column contents |
|----------|---------|-------------------------------|
| `l` | `1.0` | Sample thickness (mm) |
| `d` | `15.0` | Distance to detector (cm) |
| `shift` | `0.0` | Temporal shift (fs) |
| `x_0` | `0.5` | Displacement of probe (w_0_e) |
## Mechanisms
| Mechanism | Parameters |
| --- | --- |
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
| Mechanism | Parameters |
|--------------------------------|------------|
| Electronic (both) | 2 |
| Collisional (NLR) | 3 |
| Librational (NLR) | 4 |
| Reorientational (NLR) | 3 |
| Vibrational (NLR) | 3 |
| ESA – 3 level + triplet (both) | 10 |
| Exponential rise/decay (NLA) | 3 |
| Exponential rise/decay (NLR) | 3 |
| Exponential rise/decay (both) | 4 |
`NLR` denotes a purely refractive response, `NLA` a purely absorptive one, and
`both` a mechanism carrying each.
Pump probe offers only the `NLA` and `both` mechanisms: with the probe centred,
a `both` mechanism contributes its absorptive part, and an `NLR` mechanism
cannot change the transmission at all. Switching to Pump probe sets aside any
`NLR` mechanism already chosen; switching back restores it, provided its slot
is still empty.
## Export output
Exporting to `<name>_fit.txt` also writes, in the same directory:
| File | Contents |
| --- | --- |
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn` |
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi |
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
| File | Contents |
|----------------------------------------|------------------------------------------------------------------------------------------------------------------------------|
| `<name>_fit.txt` | delay, data and fit for `T`, `ΔE/E` and `Δn`; in Pump probe, delay and `T` only. In Simulation, the calculated signals alone |
| `<name>_fit_log.txt` | every parameter, plus a manifest of the files written |
| `<name>_fit_combined.jpg` / `.svg` | transmission and deflection, 6.5 in at 300 dpi (Beam deflection) |
| `<name>_fit_transmission.jpg` / `.svg` | transmission only, 3.25 in at 300 dpi (Pump probe) |
| `<name>_fit_raw_response.jpg` | each mechanism's `R[t]` and `A[t]` |
| `<name>_fit_convolved_response.jpg` | the same after convolution, plus the total |
The last two appear only when *Show diagnostic plots during Fit* is ticked.
The log records enough to reproduce a run: data columns and delimiter, the
simulation grid, every beam, material and geometry value, each mechanism with
its parameters, and the derived quantities (`n_g`, `T_lin`, `z_0`, `I_0`,
`rho`).
In Simulation mode the export is named after the file you choose rather than an
imported scan, and the table holds the calculated signals on their own delay
grid, with no data columns to pair them with.
The log records enough to reproduce a run: both modes, the data columns and
delimiter, the simulation grid including the delay range, every beam, material
and geometry value, each mechanism with its parameters, and the derived
quantities (`n_g`, `T_lin`, `z_0`, `I_0`, `rho`). In Simulation mode the import
path and data column sections are omitted, having nothing to describe.
## Files
| File | Role |
| --- | --- |
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
## Notes on the port
The translation follows the MATLAB closely, including its array axis order, so
that intermediate results can be compared directly. Places where this port
deliberately differs are commented at the point of departure. The substantive
ones:
- **Physical constants** are taken from `scipy.constants` rather than
transcribed. The original hard-coded `c = 299797548` in `calc_beam_params`, a
digit transposition of the correct value used elsewhere in the same codebase,
and truncated Planck's constant to seven figures. Correcting the former
shifts `rho` by about 1.7 × 10⁻⁵ relative.
- **Delay-frame consistency**: the delay grid is derived from the shifted
`τ_d`, matching what the plots and export compare against. The original used
the unshifted values, a mismatch whenever `shift ≠ 0`.
- **Diagnostic instantaneous response**: the original's diagnostic plot used
`n_2e` where its four physics branches all used `2·n_2e`, so the plotted
electronic curve was half the simulated one. The plot now matches the
simulation.
- **Dialog close**: closing the parameter dialog with the window button is
treated as OK. In the original it left the caller's `uiwait` blocked forever.
| File | Role |
|------------------------|--------------------------------------------------------------------------------------------------------------------------|
| `bd_fresnel_core.py` | physics: field propagation, mechanism responses, ESA solver, parameter dataclass, settings I/O. No display dependencies. |
| `bd_fresnel_gui.py` | Tkinter interface, plotting, import/export, logging. Entry point. |
| `set_params_dialog.py` | modal dialog for entering one mechanism's parameters. |
## References
Please cite the following when using results from this program.
1. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
dependence of the nonlinear optical response of carbon disulfide."
*Optica* **1**(6): 436.
2. Reichert, M., et al. (2014). "Temporal, spectral, and polarization
dependence of the nonlinear optical response of carbon disulfide:
supplementary material." *Optica* **1**(6): 436.
3. Ferdinandus, M. R., et al. (2013). "Beam deflection measurement of time and
polarization resolved ultrafast nonlinear refraction." *Opt. Lett.*
**38**(18): 3518–3521.
1. M. Reichert, H. Hu, M. R. Ferdinandus, M. Seidel, P. Zhao, T. R. Ensley,
D. Peceli, J. M. Reed, D. A. Fishman, S. Webster, D. J. Hagan, and
E. W. Van Stryland, “Temporal, spectral, and polarization dependence of the
nonlinear optical response of carbon disulfide,” Optica **1**, 436–445 (2014).
2. M. R. Ferdinandus, H. Hu, M. Reichert, D. J. Hagan, and E. W. Van Stryland,
“Beam deflection measurement of time and polarization resolved ultrafast
nonlinear refraction,” Opt. Lett. **38**, 3518–3521 (2013).
## License
Copyright (C) 2019-2026 Manuel R. Ferdinandus
This program is free software: you can redistribute it and/or modify it under
the terms of the GNU General Public License as published by the Free Software
Foundation, either version 3 of the License, or (at your option) any later
version.
This program is distributed in the hope that it will be useful, but WITHOUT ANY
WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A
PARTICULAR PURPOSE. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with
this program. If not, see <https://www.gnu.org/licenses/>.
NumPy, SciPy, Matplotlib and mpmath are all BSD-licensed, so distributing this program
under the GPL alongside them poses no conflict.
+737 -169
View File
File diff suppressed because it is too large Load Diff
+828 -195
View File
File diff suppressed because it is too large Load Diff
Binary file not shown.

Before

Width:  |  Height:  |  Size: 134 KiB

After

Width:  |  Height:  |  Size: 355 KiB

+165
View File
@@ -0,0 +1,165 @@
{
"E_e": 1.0,
"tau_e_FWHM": 45.0,
"w_0_e": 142.83,
"lambda_e": 800.0,
"tau_p_FWHM": 100.0,
"w_0_p": 22.253,
"lambda_p": 650.0,
"R_e": 0.0,
"alpha_e": 0.0,
"n_e": 1.4533,
"dndl_e": -0.017284,
"alpha_2d_e": 0.0,
"R_p": 0.0,
"alpha_p": 0.0,
"n_p": 1.4565,
"dndl_p": -0.027158,
"l": 1.72e-06,
"d": 15.0,
"shift": 70.0,
"x_0": 0.5,
"tau_e": 27.025254197695123,
"tau_p": 60.05612043932249,
"sigma_e": 0.0,
"I_0_e": 651473158047437.0,
"ng_e": 1.4671272,
"ng_p": 1.4741526999999999,
"rho": 0.8671350632529666,
"z_0_p": 0.0023933909907098232,
"z_0_e": 0.0801122184130848,
"Tlin_p": 1.0,
"Tlin_e": 1.0,
"X_max": 5.0,
"X_num": 50,
"T_min": -5.0,
"T_max": 5.0,
"T_num": 100,
"T_d_min": -9.579367435592124,
"T_d_max": 39.791355601447556,
"T_d_num": 150,
"n_mech": 7,
"mech": [
{
"name": "Exponential rise/decay (both)",
"param": [
3600.0,
-200000.0,
1.0,
170.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "Exponential rise/decay (both)",
"param": [
15000.0,
-500000.0,
0.1,
10000.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
},
{
"name": "None (both)",
"param": [
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0,
0.0
]
}
],
"col_tau_d": 1,
"col_DeltaEoE": 2,
"col_T": 3,
"delimiter": ",",
"diagnostics": true,
"data_imported": true,
"data_fit": true,
"mode": "beam_deflection",
"run_mode": "fitting",
"algorithm": "semi_analytical",
"x_0_beam_deflection": 0.5,
"mech_beam_deflection": [],
"filename": "20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
"pathname": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/",
"import_filepath": "/home/manuel/Documents/Projects/Code/BD_Fresnel_GUI/Test data/20190802 - BD 4 layer run 2_DeltaEoE_subtraction.txt",
"settings_schema": 3
}
+5
View File
@@ -9,4 +9,9 @@
numpy>=2.0
scipy>=1.6
matplotlib>=3.4
# Optional. Only needed for the pump two-photon absorption term
# (alpha_2d_e != 0), which uses the polylogarithm Li_3/2. The core
# imports it lazily, so the program runs without it until that term is
# used, and then says so.
mpmath>=1.2
+30 -3
View File
@@ -1,5 +1,21 @@
#!/usr/bin/env python3
# -*- coding: utf-8 -*-
# BD Fresnel - mechanism parameter dialog
#
# Copyright (C) 2019-2026 Manuel R. Ferdinandus
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <https://www.gnu.org/licenses/>.
"""
set_params_dialog.py
=====================
@@ -39,6 +55,7 @@ Usage:
previous_mechanism=old_mech)
"""
import math
import tkinter as tk
from tkinter import ttk
@@ -102,6 +119,16 @@ class SetParamsDialog(tk.Toplevel):
if self._entries and self._entries[0] is not None:
self.after(10, self._entries[0].focus_set)
@staticmethod
def _parse(text: str) -> float:
"""float(), but rejecting what it accepts and no parameter can
take: "nan", "inf", and overflows such as "1e999". Letting those
through also crashed _format, which calls int() on the value."""
value = float(text)
if not math.isfinite(value):
raise ValueError(f"{text!r} is not finite")
return value
@staticmethod
def _format(value: float) -> str:
# MATLAB's num2str-equivalent-enough default formatting.
@@ -114,10 +141,10 @@ class SetParamsDialog(tk.Toplevel):
if var is None:
return
try:
value = float(var.get())
value = self._parse(var.get())
except ValueError:
name = MECHANISM_PARAM_SPECS[self.mechanism_name][idx][0]
print(f"set_params_dialog: '{name}' must be a real number; reverting.")
print(f"set_params_dialog: '{name}' must be a finite real number; reverting.")
value = self._last_valid[idx]
self._last_valid[idx] = value
var.set(self._format(value))
@@ -128,7 +155,7 @@ class SetParamsDialog(tk.Toplevel):
if var is None:
continue
try:
values[i] = float(var.get())
values[i] = self._parse(var.get())
except ValueError:
values[i] = self._last_valid[i]
self.result = Mechanism(name=self.mechanism_name, param=values)